Cargando…
Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647422/ https://www.ncbi.nlm.nih.gov/pubmed/34865629 http://dx.doi.org/10.1186/s12968-021-00828-y |
_version_ | 1784610603298455552 |
---|---|
author | Gupta, Aakash N. Avery, Ryan Soulat, Gilles Allen, Bradley D. Collins, Jeremy D. Choudhury, Lubna Bonow, Robert O. Carr, James Markl, Michael Elbaz, Mohammed S. M. |
author_facet | Gupta, Aakash N. Avery, Ryan Soulat, Gilles Allen, Bradley D. Collins, Jeremy D. Choudhury, Lubna Bonow, Robert O. Carr, James Markl, Michael Elbaz, Mohammed S. M. |
author_sort | Gupta, Aakash N. |
collection | PubMed |
description | BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland–Altman analysis, and Cohen’s kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-021-00828-y. |
format | Online Article Text |
id | pubmed-8647422 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-86474222021-12-07 Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR Gupta, Aakash N. Avery, Ryan Soulat, Gilles Allen, Bradley D. Collins, Jeremy D. Choudhury, Lubna Bonow, Robert O. Carr, James Markl, Michael Elbaz, Mohammed S. M. J Cardiovasc Magn Reson Technical Notes BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland–Altman analysis, and Cohen’s kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-021-00828-y. BioMed Central 2021-12-06 /pmc/articles/PMC8647422/ /pubmed/34865629 http://dx.doi.org/10.1186/s12968-021-00828-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Technical Notes Gupta, Aakash N. Avery, Ryan Soulat, Gilles Allen, Bradley D. Collins, Jeremy D. Choudhury, Lubna Bonow, Robert O. Carr, James Markl, Michael Elbaz, Mohammed S. M. Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR |
title | Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR |
title_full | Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR |
title_fullStr | Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR |
title_full_unstemmed | Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR |
title_short | Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR |
title_sort | direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4d flow cmr jet tracking: evaluation in comparison to conventional cmr |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647422/ https://www.ncbi.nlm.nih.gov/pubmed/34865629 http://dx.doi.org/10.1186/s12968-021-00828-y |
work_keys_str_mv | AT guptaaakashn directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT averyryan directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT soulatgilles directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT allenbradleyd directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT collinsjeremyd directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT choudhurylubna directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT bonowroberto directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT carrjames directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT marklmichael directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr AT elbazmohammedsm directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr |