Cargando…

Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR

BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Aakash N., Avery, Ryan, Soulat, Gilles, Allen, Bradley D., Collins, Jeremy D., Choudhury, Lubna, Bonow, Robert O., Carr, James, Markl, Michael, Elbaz, Mohammed S. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647422/
https://www.ncbi.nlm.nih.gov/pubmed/34865629
http://dx.doi.org/10.1186/s12968-021-00828-y
_version_ 1784610603298455552
author Gupta, Aakash N.
Avery, Ryan
Soulat, Gilles
Allen, Bradley D.
Collins, Jeremy D.
Choudhury, Lubna
Bonow, Robert O.
Carr, James
Markl, Michael
Elbaz, Mohammed S. M.
author_facet Gupta, Aakash N.
Avery, Ryan
Soulat, Gilles
Allen, Bradley D.
Collins, Jeremy D.
Choudhury, Lubna
Bonow, Robert O.
Carr, James
Markl, Michael
Elbaz, Mohammed S. M.
author_sort Gupta, Aakash N.
collection PubMed
description BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland–Altman analysis, and Cohen’s kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-021-00828-y.
format Online
Article
Text
id pubmed-8647422
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86474222021-12-07 Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR Gupta, Aakash N. Avery, Ryan Soulat, Gilles Allen, Bradley D. Collins, Jeremy D. Choudhury, Lubna Bonow, Robert O. Carr, James Markl, Michael Elbaz, Mohammed S. M. J Cardiovasc Magn Reson Technical Notes BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland–Altman analysis, and Cohen’s kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-021-00828-y. BioMed Central 2021-12-06 /pmc/articles/PMC8647422/ /pubmed/34865629 http://dx.doi.org/10.1186/s12968-021-00828-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Technical Notes
Gupta, Aakash N.
Avery, Ryan
Soulat, Gilles
Allen, Bradley D.
Collins, Jeremy D.
Choudhury, Lubna
Bonow, Robert O.
Carr, James
Markl, Michael
Elbaz, Mohammed S. M.
Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
title Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
title_full Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
title_fullStr Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
title_full_unstemmed Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
title_short Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
title_sort direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4d flow cmr jet tracking: evaluation in comparison to conventional cmr
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647422/
https://www.ncbi.nlm.nih.gov/pubmed/34865629
http://dx.doi.org/10.1186/s12968-021-00828-y
work_keys_str_mv AT guptaaakashn directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT averyryan directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT soulatgilles directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT allenbradleyd directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT collinsjeremyd directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT choudhurylubna directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT bonowroberto directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT carrjames directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT marklmichael directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr
AT elbazmohammedsm directmitralregurgitationquantificationinhypertrophiccardiomyopathyusing4dflowcmrjettrackingevaluationincomparisontoconventionalcmr