Cargando…
Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations
The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post‐processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it diffic...
Autores principales: | , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647919/ https://www.ncbi.nlm.nih.gov/pubmed/33559967 http://dx.doi.org/10.1002/nbm.4484 |
_version_ | 1784610695373914112 |
---|---|
author | Lin, Alexander Andronesi, Ovidiu Bogner, Wolfgang Choi, In‐Young Coello, Eduardo Cudalbu, Cristina Juchem, Christoph Kemp, Graham J. Kreis, Roland Krššák, Martin Lee, Phil Maudsley, Andrew A. Meyerspeer, Martin Mlynarik, Vladamir Near, Jamie Öz, Gülin Peek, Aimie L. Puts, Nicolaas A. Ratai, Eva‐Maria Tkáč, Ivan Mullins, Paul G. |
author_facet | Lin, Alexander Andronesi, Ovidiu Bogner, Wolfgang Choi, In‐Young Coello, Eduardo Cudalbu, Cristina Juchem, Christoph Kemp, Graham J. Kreis, Roland Krššák, Martin Lee, Phil Maudsley, Andrew A. Meyerspeer, Martin Mlynarik, Vladamir Near, Jamie Öz, Gülin Peek, Aimie L. Puts, Nicolaas A. Ratai, Eva‐Maria Tkáč, Ivan Mullins, Paul G. |
author_sort | Lin, Alexander |
collection | PubMed |
description | The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post‐processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta‐analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full. |
format | Online Article Text |
id | pubmed-8647919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86479192021-12-20 Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations Lin, Alexander Andronesi, Ovidiu Bogner, Wolfgang Choi, In‐Young Coello, Eduardo Cudalbu, Cristina Juchem, Christoph Kemp, Graham J. Kreis, Roland Krššák, Martin Lee, Phil Maudsley, Andrew A. Meyerspeer, Martin Mlynarik, Vladamir Near, Jamie Öz, Gülin Peek, Aimie L. Puts, Nicolaas A. Ratai, Eva‐Maria Tkáč, Ivan Mullins, Paul G. NMR Biomed Special Issue Research Article The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post‐processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta‐analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full. John Wiley and Sons Inc. 2021-02-09 2021-05 /pmc/articles/PMC8647919/ /pubmed/33559967 http://dx.doi.org/10.1002/nbm.4484 Text en © 2021 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Special Issue Research Article Lin, Alexander Andronesi, Ovidiu Bogner, Wolfgang Choi, In‐Young Coello, Eduardo Cudalbu, Cristina Juchem, Christoph Kemp, Graham J. Kreis, Roland Krššák, Martin Lee, Phil Maudsley, Andrew A. Meyerspeer, Martin Mlynarik, Vladamir Near, Jamie Öz, Gülin Peek, Aimie L. Puts, Nicolaas A. Ratai, Eva‐Maria Tkáč, Ivan Mullins, Paul G. Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations |
title | Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations |
title_full | Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations |
title_fullStr | Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations |
title_full_unstemmed | Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations |
title_short | Minimum Reporting Standards for in vivo Magnetic Resonance Spectroscopy (MRSinMRS): Experts' consensus recommendations |
title_sort | minimum reporting standards for in vivo magnetic resonance spectroscopy (mrsinmrs): experts' consensus recommendations |
topic | Special Issue Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647919/ https://www.ncbi.nlm.nih.gov/pubmed/33559967 http://dx.doi.org/10.1002/nbm.4484 |
work_keys_str_mv | AT linalexander minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT andronesiovidiu minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT bognerwolfgang minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT choiinyoung minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT coelloeduardo minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT cudalbucristina minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT juchemchristoph minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT kempgrahamj minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT kreisroland minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT krssakmartin minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT leephil minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT maudsleyandrewa minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT meyerspeermartin minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT mlynarikvladamir minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT nearjamie minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT ozgulin minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT peekaimiel minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT putsnicolaasa minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT rataievamaria minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT tkacivan minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT mullinspaulg minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations AT minimumreportingstandardsforinvivomagneticresonancespectroscopymrsinmrsexpertsconsensusrecommendations |