Cargando…
Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model
BACKGROUND: A major drawback of liquid embolic agents (LEAs) is the generation of imaging artifacts (IA), which may represent a crucial obstacle for the detection of periprocedural hemorrhage or subsequent radiosurgery of cerebral arteriovenous malformations (AVMs). This study aimed to compare the I...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8648665/ https://www.ncbi.nlm.nih.gov/pubmed/33852036 http://dx.doi.org/10.1007/s00062-021-01013-5 |
_version_ | 1784610856043020288 |
---|---|
author | Schmitt, Niclas Floca, Ralf O Paech, Daniel El Shafie, Rami A Neuberger, Ulf Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F |
author_facet | Schmitt, Niclas Floca, Ralf O Paech, Daniel El Shafie, Rami A Neuberger, Ulf Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F |
author_sort | Schmitt, Niclas |
collection | PubMed |
description | BACKGROUND: A major drawback of liquid embolic agents (LEAs) is the generation of imaging artifacts (IA), which may represent a crucial obstacle for the detection of periprocedural hemorrhage or subsequent radiosurgery of cerebral arteriovenous malformations (AVMs). This study aimed to compare the IAs of Onyx, Squid and PHIL in a novel three-dimensional in vitro AVM model in conventional computed tomography (CT) and cone-beam CT (CBCT). METHODS: Tubes with different diameters were configured in a container resembling an AVM with an artificial nidus at its center. Subsequently, the AVM models were filled with Onyx 18, Squid 18, PHIL 25% or saline and inserted into an imaging phantom (n = 10/LEA). Afterwards CT and CBCT scans were acquired. The degree of IAs was graded quantitatively (Hounsfield units in a defined region of interest) and qualitatively (feasibility of defining the nidus)—Onyx vs. Squid vs. PHIL vs. saline, respectively. RESULTS: Quantitative density evaluation demonstrated more artifacts for Onyx compared to Squid and PHIL, e.g. 48.15 ± 14.32 HU for Onyx vs. 7.56 ± 1.34 HU for PHIL in CT (p < 0.001) and 41.88 ± 7.22 density units (DU) for Squid vs. 35.22 ± 5.84 DU for PHIL in CBCT (p = 0.044). Qualitative analysis showed less artifacts for PHIL compared to Onyx and Squid in both imaging modalities while there was no difference between Onyx and Squid regarding the definition of the nidus (p > 0.999). CONCLUSION: In this novel three-dimensional in vitro AVM model, IAs were higher for the EVOH/tantalum-based LEAs Onyx and Squid compared to iodine-based PHIL. Onyx induced the highest degree of IAs with only minor differences to Squid. |
format | Online Article Text |
id | pubmed-8648665 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-86486652021-12-08 Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model Schmitt, Niclas Floca, Ralf O Paech, Daniel El Shafie, Rami A Neuberger, Ulf Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F Clin Neuroradiol Original Article BACKGROUND: A major drawback of liquid embolic agents (LEAs) is the generation of imaging artifacts (IA), which may represent a crucial obstacle for the detection of periprocedural hemorrhage or subsequent radiosurgery of cerebral arteriovenous malformations (AVMs). This study aimed to compare the IAs of Onyx, Squid and PHIL in a novel three-dimensional in vitro AVM model in conventional computed tomography (CT) and cone-beam CT (CBCT). METHODS: Tubes with different diameters were configured in a container resembling an AVM with an artificial nidus at its center. Subsequently, the AVM models were filled with Onyx 18, Squid 18, PHIL 25% or saline and inserted into an imaging phantom (n = 10/LEA). Afterwards CT and CBCT scans were acquired. The degree of IAs was graded quantitatively (Hounsfield units in a defined region of interest) and qualitatively (feasibility of defining the nidus)—Onyx vs. Squid vs. PHIL vs. saline, respectively. RESULTS: Quantitative density evaluation demonstrated more artifacts for Onyx compared to Squid and PHIL, e.g. 48.15 ± 14.32 HU for Onyx vs. 7.56 ± 1.34 HU for PHIL in CT (p < 0.001) and 41.88 ± 7.22 density units (DU) for Squid vs. 35.22 ± 5.84 DU for PHIL in CBCT (p = 0.044). Qualitative analysis showed less artifacts for PHIL compared to Onyx and Squid in both imaging modalities while there was no difference between Onyx and Squid regarding the definition of the nidus (p > 0.999). CONCLUSION: In this novel three-dimensional in vitro AVM model, IAs were higher for the EVOH/tantalum-based LEAs Onyx and Squid compared to iodine-based PHIL. Onyx induced the highest degree of IAs with only minor differences to Squid. Springer Berlin Heidelberg 2021-04-14 2021 /pmc/articles/PMC8648665/ /pubmed/33852036 http://dx.doi.org/10.1007/s00062-021-01013-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Schmitt, Niclas Floca, Ralf O Paech, Daniel El Shafie, Rami A Neuberger, Ulf Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model |
title | Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model |
title_full | Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model |
title_fullStr | Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model |
title_full_unstemmed | Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model |
title_short | Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model |
title_sort | imaging artifacts of nonadhesive liquid embolic agents in conventional and cone-beam ct in a novel in vitro avm model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8648665/ https://www.ncbi.nlm.nih.gov/pubmed/33852036 http://dx.doi.org/10.1007/s00062-021-01013-5 |
work_keys_str_mv | AT schmittniclas imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT flocaralfo imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT paechdaniel imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT elshafieramia imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT neubergerulf imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT bendszusmartin imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT mohlenbruchmarkusa imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel AT vollherbstdominikf imagingartifactsofnonadhesiveliquidembolicagentsinconventionalandconebeamctinanovelinvitroavmmodel |