Cargando…

Automated alert and activation of medical emergency team using early warning score

BACKGROUND: Timely recognition of warning signs from deteriorating patients and proper treatment are important in improving patient safety. In comparison to the traditional medical emergency team (MET) activation triggered by phone calls, automated activation of MET may minimize activation delays. H...

Descripción completa

Detalles Bibliográficos
Autores principales: Na, Soo Jin, Ko, Ryoung-Eun, Ko, Myeong Gyun, Jeon, Kyeongman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8650341/
https://www.ncbi.nlm.nih.gov/pubmed/34876209
http://dx.doi.org/10.1186/s40560-021-00588-y
_version_ 1784611180312002560
author Na, Soo Jin
Ko, Ryoung-Eun
Ko, Myeong Gyun
Jeon, Kyeongman
author_facet Na, Soo Jin
Ko, Ryoung-Eun
Ko, Myeong Gyun
Jeon, Kyeongman
author_sort Na, Soo Jin
collection PubMed
description BACKGROUND: Timely recognition of warning signs from deteriorating patients and proper treatment are important in improving patient safety. In comparison to the traditional medical emergency team (MET) activation triggered by phone calls, automated activation of MET may minimize activation delays. However, limited data are available on the effects of automated activation systems on the time from derangement to MET activation and on clinical outcomes. The objective of this study was to determine the impact of an automated alert and activation system for MET on clinical outcomes in unselected hospitalized patients. METHODS: This is an observational study using prospectively collected data from consecutive patients managed by the MET at a university-affiliated, tertiary hospital from March 2013 to December 2019. The automated alert system automatically calculates the Modified Early Warning Score (MEWS) and subsequently activates MET when the MEWS score is 7 or higher, which was implemented since August 2016. The outcome measures of interest including hospital mortality in patients with MEWS of 7 or higher were compared between pre-implementation and post-implementation groups of the automated alert and activation system in the primary analysis. The association between the implementation of the system and hospital mortality was evaluated with logistic regression analysis. RESULTS: Of the 7678 patients who were managed by MET during the study period, 639 patients during the pre-implementation period and 957 patients during the post-implementation period were included in the primary analysis. MET calls due to abnormal physiological variables were more common during the pre-implementation period, while MET calls due to medical staff’s worries or concern about the patient’s condition were more common during the post-implementation period. The median time from deterioration to MET activation was significantly shortened in the post-implementation period compared to the pre-implementation period (34 min vs. 60 min, P < 0.001). In addition, unplanned ICU admission rates (41.2% vs. 71.8%, P < 0.001) was reduced during the post-implementation period. Hospital mortality was decreased after implementation of the automated alert system (27.2% vs. 38.5%, P < 0.001). The implementation of the automated alert and activation system was associated with decreased risk of death in the multivariable analysis (adjusted OR 0.73, 95% CI 0.56–0.90). CONCLUSIONS: After implementing an automated alert and activation system, the time from deterioration to MET activation was shortened and clinical outcomes were improved in hospitalized patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40560-021-00588-y.
format Online
Article
Text
id pubmed-8650341
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86503412021-12-07 Automated alert and activation of medical emergency team using early warning score Na, Soo Jin Ko, Ryoung-Eun Ko, Myeong Gyun Jeon, Kyeongman J Intensive Care Research BACKGROUND: Timely recognition of warning signs from deteriorating patients and proper treatment are important in improving patient safety. In comparison to the traditional medical emergency team (MET) activation triggered by phone calls, automated activation of MET may minimize activation delays. However, limited data are available on the effects of automated activation systems on the time from derangement to MET activation and on clinical outcomes. The objective of this study was to determine the impact of an automated alert and activation system for MET on clinical outcomes in unselected hospitalized patients. METHODS: This is an observational study using prospectively collected data from consecutive patients managed by the MET at a university-affiliated, tertiary hospital from March 2013 to December 2019. The automated alert system automatically calculates the Modified Early Warning Score (MEWS) and subsequently activates MET when the MEWS score is 7 or higher, which was implemented since August 2016. The outcome measures of interest including hospital mortality in patients with MEWS of 7 or higher were compared between pre-implementation and post-implementation groups of the automated alert and activation system in the primary analysis. The association between the implementation of the system and hospital mortality was evaluated with logistic regression analysis. RESULTS: Of the 7678 patients who were managed by MET during the study period, 639 patients during the pre-implementation period and 957 patients during the post-implementation period were included in the primary analysis. MET calls due to abnormal physiological variables were more common during the pre-implementation period, while MET calls due to medical staff’s worries or concern about the patient’s condition were more common during the post-implementation period. The median time from deterioration to MET activation was significantly shortened in the post-implementation period compared to the pre-implementation period (34 min vs. 60 min, P < 0.001). In addition, unplanned ICU admission rates (41.2% vs. 71.8%, P < 0.001) was reduced during the post-implementation period. Hospital mortality was decreased after implementation of the automated alert system (27.2% vs. 38.5%, P < 0.001). The implementation of the automated alert and activation system was associated with decreased risk of death in the multivariable analysis (adjusted OR 0.73, 95% CI 0.56–0.90). CONCLUSIONS: After implementing an automated alert and activation system, the time from deterioration to MET activation was shortened and clinical outcomes were improved in hospitalized patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40560-021-00588-y. BioMed Central 2021-12-07 /pmc/articles/PMC8650341/ /pubmed/34876209 http://dx.doi.org/10.1186/s40560-021-00588-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Na, Soo Jin
Ko, Ryoung-Eun
Ko, Myeong Gyun
Jeon, Kyeongman
Automated alert and activation of medical emergency team using early warning score
title Automated alert and activation of medical emergency team using early warning score
title_full Automated alert and activation of medical emergency team using early warning score
title_fullStr Automated alert and activation of medical emergency team using early warning score
title_full_unstemmed Automated alert and activation of medical emergency team using early warning score
title_short Automated alert and activation of medical emergency team using early warning score
title_sort automated alert and activation of medical emergency team using early warning score
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8650341/
https://www.ncbi.nlm.nih.gov/pubmed/34876209
http://dx.doi.org/10.1186/s40560-021-00588-y
work_keys_str_mv AT nasoojin automatedalertandactivationofmedicalemergencyteamusingearlywarningscore
AT koryoungeun automatedalertandactivationofmedicalemergencyteamusingearlywarningscore
AT komyeonggyun automatedalertandactivationofmedicalemergencyteamusingearlywarningscore
AT jeonkyeongman automatedalertandactivationofmedicalemergencyteamusingearlywarningscore