OBJECTIVES: This study was conducted to compare refractive error measurements recorded using the Nidek HandyRef-K handheld autorefractometer (HDY; Nidek Co. Ltd., Tokyo, Japan), Plusoptix A09 photorefractor (PO; Plusoptix GmbH, Nuremberg, Germany), Retinomax K-plus 3 (RTX; Right Mfg. Co. Ltd., Tokyo...

Descripción completa

Detalles Bibliográficos
Autores principales: Seymen, Zeynep, Bekmez, Sinan, Eris, Erdem, Yildiz, Burcin Kepez, Vural, Asli, Ogreden, Tulin, Perente, Irfan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651018/
https://www.ncbi.nlm.nih.gov/pubmed/35005503
http://dx.doi.org/10.14744/bej.2021.28247
_version_ 1784611324020391936
author Seymen, Zeynep
Bekmez, Sinan
Eris, Erdem
Yildiz, Burcin Kepez
Vural, Asli
Ogreden, Tulin
Perente, Irfan
author_facet Seymen, Zeynep
Bekmez, Sinan
Eris, Erdem
Yildiz, Burcin Kepez
Vural, Asli
Ogreden, Tulin
Perente, Irfan
author_sort Seymen, Zeynep
collection PubMed
description OBJECTIVES: This study was conducted to compare refractive error measurements recorded using the Nidek HandyRef-K handheld autorefractometer (HDY; Nidek Co. Ltd., Tokyo, Japan), Plusoptix A09 photorefractor (PO; Plusoptix GmbH, Nuremberg, Germany), Retinomax K-plus 3 (RTX; Right Mfg. Co. Ltd., Tokyo, Japan), and a table-mounted autorefractometer/keratometer (TTR; URK 800, Unicos Co. Ltd., Daejeon, Republic of Korea). METHODS: Patients aged ≥18 years underwent measurement of refraction without cycloplegia using 4 devices and the spherical power (SP), cylindrical power (CP), and spherical equivalent (SE) values were analyzed and compared. RESULTS: A total of 181 eyes of 181 patients were enrolled in the study. The mean age of the patients was 33.08±0.95 years (range: 18-79 years). There was a significantly significant difference in the SP, CP, and SE values determined by the devices (p<0.001). The SP and SE values of the RTX and the HDY were similar, while the other device results were different (Wilcoxon signed-rank test, p=0.004). The CP values of the PO and the TTR, the HDY and the TTR were also comparable. CONCLUSION: The HDY, RTX, and the PO are suitable for screening in clinical practice, but the findings strongly suggest that they should be used with caution.
format Online
Article
Text
id pubmed-8651018
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-86510182022-01-07 Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices Seymen, Zeynep Bekmez, Sinan Eris, Erdem Yildiz, Burcin Kepez Vural, Asli Ogreden, Tulin Perente, Irfan Beyoglu Eye J Original Article OBJECTIVES: This study was conducted to compare refractive error measurements recorded using the Nidek HandyRef-K handheld autorefractometer (HDY; Nidek Co. Ltd., Tokyo, Japan), Plusoptix A09 photorefractor (PO; Plusoptix GmbH, Nuremberg, Germany), Retinomax K-plus 3 (RTX; Right Mfg. Co. Ltd., Tokyo, Japan), and a table-mounted autorefractometer/keratometer (TTR; URK 800, Unicos Co. Ltd., Daejeon, Republic of Korea). METHODS: Patients aged ≥18 years underwent measurement of refraction without cycloplegia using 4 devices and the spherical power (SP), cylindrical power (CP), and spherical equivalent (SE) values were analyzed and compared. RESULTS: A total of 181 eyes of 181 patients were enrolled in the study. The mean age of the patients was 33.08±0.95 years (range: 18-79 years). There was a significantly significant difference in the SP, CP, and SE values determined by the devices (p<0.001). The SP and SE values of the RTX and the HDY were similar, while the other device results were different (Wilcoxon signed-rank test, p=0.004). The CP values of the PO and the TTR, the HDY and the TTR were also comparable. CONCLUSION: The HDY, RTX, and the PO are suitable for screening in clinical practice, but the findings strongly suggest that they should be used with caution. Kare Publishing 2021-06-08 /pmc/articles/PMC8651018/ /pubmed/35005503 http://dx.doi.org/10.14744/bej.2021.28247 Text en Copyright: © 2021 by Beyoglu Eye Training and Research Hospital https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
spellingShingle Original Article
Seymen, Zeynep
Bekmez, Sinan
Eris, Erdem
Yildiz, Burcin Kepez
Vural, Asli
Ogreden, Tulin
Perente, Irfan
Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices
title Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices
title_full Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices
title_fullStr Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices
title_full_unstemmed Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices
title_short Comparison of Adult Refractive Disorder Measurements Using HandyRef-K, Retinomax, Plusoptix, and Table-top Autorefractometer Devices
title_sort comparison of adult refractive disorder measurements using handyref-k, retinomax, plusoptix, and table-top autorefractometer devices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651018/
https://www.ncbi.nlm.nih.gov/pubmed/35005503
http://dx.doi.org/10.14744/bej.2021.28247
work_keys_str_mv AT seymenzeynep comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices
AT bekmezsinan comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices
AT eriserdem comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices
AT yildizburcinkepez comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices
AT vuralasli comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices
AT ogredentulin comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices
AT perenteirfan comparisonofadultrefractivedisordermeasurementsusinghandyrefkretinomaxplusoptixandtabletopautorefractometerdevices