Cargando…
Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy
The single-photon timing and sensitivity performance and the imaging ability of asynchronous-readout single-photon avalanche diode (SPAD) array detectors have opened up enormous perspectives in fluorescence (lifetime) laser scanning microscopy (FLSM), such as super-resolution image scanning microsco...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651514/ https://www.ncbi.nlm.nih.gov/pubmed/34939046 http://dx.doi.org/10.1016/j.bpr.2021.100025 |
_version_ | 1784611412996259840 |
---|---|
author | Slenders, Eli Perego, Eleonora Buttafava, Mauro Tortarolo, Giorgio Conca, Enrico Zappone, Sabrina Pierzynska-Mach, Agnieszka Villa, Federica Petrini, Enrica Maria Barberis, Andrea Tosi, Alberto Vicidomini, Giuseppe |
author_facet | Slenders, Eli Perego, Eleonora Buttafava, Mauro Tortarolo, Giorgio Conca, Enrico Zappone, Sabrina Pierzynska-Mach, Agnieszka Villa, Federica Petrini, Enrica Maria Barberis, Andrea Tosi, Alberto Vicidomini, Giuseppe |
author_sort | Slenders, Eli |
collection | PubMed |
description | The single-photon timing and sensitivity performance and the imaging ability of asynchronous-readout single-photon avalanche diode (SPAD) array detectors have opened up enormous perspectives in fluorescence (lifetime) laser scanning microscopy (FLSM), such as super-resolution image scanning microscopy and high-information content fluorescence fluctuation spectroscopy. However, the strengths of these FLSM techniques depend on the many different characteristics of the detector, such as dark noise, photon-detection efficiency, after-pulsing probability, and optical cross talk, whose overall optimization is typically a trade-off between these characteristics. To mitigate this trade-off, we present, to our knowledge, a novel SPAD array detector with an active cooling system that substantially reduces the dark noise without significantly deteriorating any other detector characteristics. In particular, we show that lowering the temperature of the sensor to −15°C significantly improves the signal/noise ratio due to a 10-fold decrease in the dark count rate compared with room temperature. As a result, for imaging, the laser power can be decreased by more than a factor of three, which is particularly beneficial for live-cell super-resolution imaging, as demonstrated in fixed and living cells expressing green-fluorescent-protein-tagged proteins. For fluorescence fluctuation spectroscopy, together with the benefit of the reduced laser power, we show that cooling the detector is necessary to remove artifacts in the correlation function, such as spurious negative correlations observed in the hot elements of the detector, i.e., elements for which dark noise is substantially higher than the median value. Overall, this detector represents a further step toward the integration of SPAD array detectors in any FLSM system. |
format | Online Article Text |
id | pubmed-8651514 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-86515142021-12-20 Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy Slenders, Eli Perego, Eleonora Buttafava, Mauro Tortarolo, Giorgio Conca, Enrico Zappone, Sabrina Pierzynska-Mach, Agnieszka Villa, Federica Petrini, Enrica Maria Barberis, Andrea Tosi, Alberto Vicidomini, Giuseppe Biophys Rep (N Y) Article The single-photon timing and sensitivity performance and the imaging ability of asynchronous-readout single-photon avalanche diode (SPAD) array detectors have opened up enormous perspectives in fluorescence (lifetime) laser scanning microscopy (FLSM), such as super-resolution image scanning microscopy and high-information content fluorescence fluctuation spectroscopy. However, the strengths of these FLSM techniques depend on the many different characteristics of the detector, such as dark noise, photon-detection efficiency, after-pulsing probability, and optical cross talk, whose overall optimization is typically a trade-off between these characteristics. To mitigate this trade-off, we present, to our knowledge, a novel SPAD array detector with an active cooling system that substantially reduces the dark noise without significantly deteriorating any other detector characteristics. In particular, we show that lowering the temperature of the sensor to −15°C significantly improves the signal/noise ratio due to a 10-fold decrease in the dark count rate compared with room temperature. As a result, for imaging, the laser power can be decreased by more than a factor of three, which is particularly beneficial for live-cell super-resolution imaging, as demonstrated in fixed and living cells expressing green-fluorescent-protein-tagged proteins. For fluorescence fluctuation spectroscopy, together with the benefit of the reduced laser power, we show that cooling the detector is necessary to remove artifacts in the correlation function, such as spurious negative correlations observed in the hot elements of the detector, i.e., elements for which dark noise is substantially higher than the median value. Overall, this detector represents a further step toward the integration of SPAD array detectors in any FLSM system. Elsevier 2021-09-17 /pmc/articles/PMC8651514/ /pubmed/34939046 http://dx.doi.org/10.1016/j.bpr.2021.100025 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Slenders, Eli Perego, Eleonora Buttafava, Mauro Tortarolo, Giorgio Conca, Enrico Zappone, Sabrina Pierzynska-Mach, Agnieszka Villa, Federica Petrini, Enrica Maria Barberis, Andrea Tosi, Alberto Vicidomini, Giuseppe Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy |
title | Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy |
title_full | Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy |
title_fullStr | Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy |
title_full_unstemmed | Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy |
title_short | Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy |
title_sort | cooled spad array detector for low light-dose fluorescence laser scanning microscopy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651514/ https://www.ncbi.nlm.nih.gov/pubmed/34939046 http://dx.doi.org/10.1016/j.bpr.2021.100025 |
work_keys_str_mv | AT slenderseli cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT peregoeleonora cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT buttafavamauro cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT tortarologiorgio cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT concaenrico cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT zapponesabrina cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT pierzynskamachagnieszka cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT villafederica cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT petrinienricamaria cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT barberisandrea cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT tosialberto cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy AT vicidominigiuseppe cooledspadarraydetectorforlowlightdosefluorescencelaserscanningmicroscopy |