Cargando…

Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices

Thrombocytopenia after TAVI is common and clinically detrimental. Retrospectively, we observed Portico recipients had a more profound platelet drop than Evolut recipients. We thus investigated periprocedural platelet damage and/orpro-inflammatory state in 64 TAVI recipients at baseline and after imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Corcione, Nicola, Romano, Simona, Morello, Alberto, Ferraro, Paolo, Cimmino, Michele, Albanese, Michele, Tufano, Martina, Capasso, Daniela, Buonpane, Salvatore, Giordano, Salvatore, Pepe, Martino, Biondi-Zoccai, Giuseppe, Romano, Maria Fiammetta, Giordano, Arturo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651580/
https://www.ncbi.nlm.nih.gov/pubmed/33721196
http://dx.doi.org/10.1007/s12265-021-10117-9
_version_ 1784611428181737472
author Corcione, Nicola
Romano, Simona
Morello, Alberto
Ferraro, Paolo
Cimmino, Michele
Albanese, Michele
Tufano, Martina
Capasso, Daniela
Buonpane, Salvatore
Giordano, Salvatore
Pepe, Martino
Biondi-Zoccai, Giuseppe
Romano, Maria Fiammetta
Giordano, Arturo
author_facet Corcione, Nicola
Romano, Simona
Morello, Alberto
Ferraro, Paolo
Cimmino, Michele
Albanese, Michele
Tufano, Martina
Capasso, Daniela
Buonpane, Salvatore
Giordano, Salvatore
Pepe, Martino
Biondi-Zoccai, Giuseppe
Romano, Maria Fiammetta
Giordano, Arturo
author_sort Corcione, Nicola
collection PubMed
description Thrombocytopenia after TAVI is common and clinically detrimental. Retrospectively, we observed Portico recipients had a more profound platelet drop than Evolut recipients. We thus investigated periprocedural platelet damage and/orpro-inflammatory state in 64 TAVI recipients at baseline and after implantation. Platelet damage was assessed by annexin V staining and monocyte-phagocytic phenotype was assessed according to CD14/CD36 expression. Serum cytokines were measured in 20 patients. The formaldehyde-based storage solution altered platelets. When, before being loaded onto the delivery system, Portico underwent one additional flushing to those recommended, the receiving patients showed thrombocytopenia, platelet damage, and CD36-monocyte count were mitigated. A general increase in IL-6 was recorded in overall TAVI recipients, but a high serum level of IL-8, a potent thrombocytopenia inducer, was measured in Portico recipients only, including those with extra-rinsed valve. Our study suggests a platelet-injury effect by storage-solution and generates the hypothesis of a role for the biomaterial in stimulating innate-immunity. Larger prospective studies are needed. [Figure: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12265-021-10117-9.
format Online
Article
Text
id pubmed-8651580
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-86515802021-12-08 Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices Corcione, Nicola Romano, Simona Morello, Alberto Ferraro, Paolo Cimmino, Michele Albanese, Michele Tufano, Martina Capasso, Daniela Buonpane, Salvatore Giordano, Salvatore Pepe, Martino Biondi-Zoccai, Giuseppe Romano, Maria Fiammetta Giordano, Arturo J Cardiovasc Transl Res Original Article Thrombocytopenia after TAVI is common and clinically detrimental. Retrospectively, we observed Portico recipients had a more profound platelet drop than Evolut recipients. We thus investigated periprocedural platelet damage and/orpro-inflammatory state in 64 TAVI recipients at baseline and after implantation. Platelet damage was assessed by annexin V staining and monocyte-phagocytic phenotype was assessed according to CD14/CD36 expression. Serum cytokines were measured in 20 patients. The formaldehyde-based storage solution altered platelets. When, before being loaded onto the delivery system, Portico underwent one additional flushing to those recommended, the receiving patients showed thrombocytopenia, platelet damage, and CD36-monocyte count were mitigated. A general increase in IL-6 was recorded in overall TAVI recipients, but a high serum level of IL-8, a potent thrombocytopenia inducer, was measured in Portico recipients only, including those with extra-rinsed valve. Our study suggests a platelet-injury effect by storage-solution and generates the hypothesis of a role for the biomaterial in stimulating innate-immunity. Larger prospective studies are needed. [Figure: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12265-021-10117-9. Springer US 2021-03-15 2021 /pmc/articles/PMC8651580/ /pubmed/33721196 http://dx.doi.org/10.1007/s12265-021-10117-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Corcione, Nicola
Romano, Simona
Morello, Alberto
Ferraro, Paolo
Cimmino, Michele
Albanese, Michele
Tufano, Martina
Capasso, Daniela
Buonpane, Salvatore
Giordano, Salvatore
Pepe, Martino
Biondi-Zoccai, Giuseppe
Romano, Maria Fiammetta
Giordano, Arturo
Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices
title Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices
title_full Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices
title_fullStr Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices
title_full_unstemmed Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices
title_short Thrombocytopenia Complicating Transcatheter Aortic Valve Implantation: Differences Between Two New-Generation Devices
title_sort thrombocytopenia complicating transcatheter aortic valve implantation: differences between two new-generation devices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651580/
https://www.ncbi.nlm.nih.gov/pubmed/33721196
http://dx.doi.org/10.1007/s12265-021-10117-9
work_keys_str_mv AT corcionenicola thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT romanosimona thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT morelloalberto thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT ferraropaolo thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT cimminomichele thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT albanesemichele thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT tufanomartina thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT capassodaniela thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT buonpanesalvatore thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT giordanosalvatore thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT pepemartino thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT biondizoccaigiuseppe thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT romanomariafiammetta thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices
AT giordanoarturo thrombocytopeniacomplicatingtranscatheteraorticvalveimplantationdifferencesbetweentwonewgenerationdevices