Cargando…
Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna
BACKGROUND: To suggest a reasonable isometric point based on the anatomical consistency of interosseous membrane (IOM) attachment in association with topographic characteristics of the interosseous crests, the footprints of the central band (CB) of the IOM on the radial and ulnar interosseous crests...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Shoulder and Elbow Society
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651595/ https://www.ncbi.nlm.nih.gov/pubmed/34875732 http://dx.doi.org/10.5397/cise.2021.00451 |
_version_ | 1784611431922008064 |
---|---|
author | Jang, Suk-Hwan Kim, Kyung-Whan Jang, Hyo Seok Kim, Yeong-Seok Kim, Hojin Kim, Youngbok |
author_facet | Jang, Suk-Hwan Kim, Kyung-Whan Jang, Hyo Seok Kim, Yeong-Seok Kim, Hojin Kim, Youngbok |
author_sort | Jang, Suk-Hwan |
collection | PubMed |
description | BACKGROUND: To suggest a reasonable isometric point based on the anatomical consistency of interosseous membrane (IOM) attachment in association with topographic characteristics of the interosseous crests, the footprints of the central band (CB) of the IOM on the radial and ulnar interosseous crests (RIC and UIC) were measured. METHODS: We measured the distance from the CB footprints from each apex of both interosseous crests in 14 cadavers and the angles between the forearm axis of rotation (AOR) and the distal slopes of the RIC and UIC in 33 volunteers. RESULTS: The CB footprints lay on the downslope of both interosseous crests with its upper margin on average 3-mm proximal from the RIC's apex consistently in the radial length, showing normality (p>0.05), and on average 16-mm distal from the UIC's apex on the ulna without satisfying normality (p<0.05). The average angle between the UIC's distal slope and the AOR was 1.3°, and the RIC's distal slope to the AOR was 14.0°, satisfying the normality tests (p>0.05), and there was no side-to-side difference in both forearms (p<0.05). CONCLUSIONS: The CB attached to the downslope just distal to the RIC's apex constrains the radius to the UIC that coincides with the AOR of the forearm circumduction, maintaining itself both isometrically and isotonically. |
format | Online Article Text |
id | pubmed-8651595 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Shoulder and Elbow Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-86515952021-12-20 Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna Jang, Suk-Hwan Kim, Kyung-Whan Jang, Hyo Seok Kim, Yeong-Seok Kim, Hojin Kim, Youngbok Clin Shoulder Elb Original Article BACKGROUND: To suggest a reasonable isometric point based on the anatomical consistency of interosseous membrane (IOM) attachment in association with topographic characteristics of the interosseous crests, the footprints of the central band (CB) of the IOM on the radial and ulnar interosseous crests (RIC and UIC) were measured. METHODS: We measured the distance from the CB footprints from each apex of both interosseous crests in 14 cadavers and the angles between the forearm axis of rotation (AOR) and the distal slopes of the RIC and UIC in 33 volunteers. RESULTS: The CB footprints lay on the downslope of both interosseous crests with its upper margin on average 3-mm proximal from the RIC's apex consistently in the radial length, showing normality (p>0.05), and on average 16-mm distal from the UIC's apex on the ulna without satisfying normality (p<0.05). The average angle between the UIC's distal slope and the AOR was 1.3°, and the RIC's distal slope to the AOR was 14.0°, satisfying the normality tests (p>0.05), and there was no side-to-side difference in both forearms (p<0.05). CONCLUSIONS: The CB attached to the downslope just distal to the RIC's apex constrains the radius to the UIC that coincides with the AOR of the forearm circumduction, maintaining itself both isometrically and isotonically. Korean Shoulder and Elbow Society 2021-12-01 /pmc/articles/PMC8651595/ /pubmed/34875732 http://dx.doi.org/10.5397/cise.2021.00451 Text en Copyright © 2021 Korean Shoulder and Elbow Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Jang, Suk-Hwan Kim, Kyung-Whan Jang, Hyo Seok Kim, Yeong-Seok Kim, Hojin Kim, Youngbok Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
title | Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
title_full | Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
title_fullStr | Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
title_full_unstemmed | Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
title_short | Topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
title_sort | topographical measurement of the attachments of the central band of the interosseous membrane on interosseous crests of the radius and ulna |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651595/ https://www.ncbi.nlm.nih.gov/pubmed/34875732 http://dx.doi.org/10.5397/cise.2021.00451 |
work_keys_str_mv | AT jangsukhwan topographicalmeasurementoftheattachmentsofthecentralbandoftheinterosseousmembraneoninterosseouscrestsoftheradiusandulna AT kimkyungwhan topographicalmeasurementoftheattachmentsofthecentralbandoftheinterosseousmembraneoninterosseouscrestsoftheradiusandulna AT janghyoseok topographicalmeasurementoftheattachmentsofthecentralbandoftheinterosseousmembraneoninterosseouscrestsoftheradiusandulna AT kimyeongseok topographicalmeasurementoftheattachmentsofthecentralbandoftheinterosseousmembraneoninterosseouscrestsoftheradiusandulna AT kimhojin topographicalmeasurementoftheattachmentsofthecentralbandoftheinterosseousmembraneoninterosseouscrestsoftheradiusandulna AT kimyoungbok topographicalmeasurementoftheattachmentsofthecentralbandoftheinterosseousmembraneoninterosseouscrestsoftheradiusandulna |