Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations

Background and objective Excessive noise in the neonatal intensive care unit (NICU) may lead to serious long-term effects on hearing and sensory development in newborns. As such, the maximum allowed noise level is 45 A-weighted decibels (dBA). Studies regarding noise exposure to ventilated preterm i...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Devika, Fusch, Gerhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8653757/
https://www.ncbi.nlm.nih.gov/pubmed/34909314
http://dx.doi.org/10.7759/cureus.19353
_version_ 1784611733360345088
author Singh, Devika
Fusch, Gerhard
author_facet Singh, Devika
Fusch, Gerhard
author_sort Singh, Devika
collection PubMed
description Background and objective Excessive noise in the neonatal intensive care unit (NICU) may lead to serious long-term effects on hearing and sensory development in newborns. As such, the maximum allowed noise level is 45 A-weighted decibels (dBA). Studies regarding noise exposure to ventilated preterm infants show inconsistent results; however, these studies also vary considerably in their methodology in terms of noise ascertainment. We hypothesized that the study methodology can significantly influence data quality when measuring noise levels. In this study, we aimed to investigate whether the variations in ventilator noise levels in NICUs could be a result of methodological differences in study designs. Methods A ventilator circuit was set up using nasal continuous positive airway pressure (nCPAP) and high-frequency (HF) modes with nasal prongs. Noise levels were measured using a commercially calibrated noise meter. Three different scenarios were tested: (1) measurements were taken at different angles (0° to 180°), with 180° facing the end of the nasal prongs, without a mannequin, with the membrane/orifice of the noise meter placed 2 mm laterally from the prongs; (2) noise levels were measured at 180° at distances of 0-20 mm from the nasal prongs; (3) measurements were taken in the oral cavity of a life-size intubation mannequin of a newborn baby. Results Overall, the noise levels produced at different settings varied significantly, ranging from 45.7 dB to 82.2 dB. The average environmental background noise was 44.4 dB. Noise levels typically increased as the angle increased, with the highest noise level recorded at 180° for both HF and nCPAP modes, at 58.4 dB and 58.2 dB, respectively. Noise levels recorded at HF were slightly higher than nCPAP values. Furthermore, with regard to distance, the highest mean value, 82.2 dB, was recorded with the noise meter approximately 3 mm from the nasal prongs, and the lowest mean value, 47.6 dB, was recorded at ~20 mm. During trials with the mannequin, the lowest value, 50.1 dB, was recorded at the entrance of the mouth with slightly higher values being recorded within the oral cavity. Conclusion The results indicate that small changes in experimental settings, such as positioning and distance from the nasal prongs, can greatly influence noise levels, particularly above the recommended levels for neonates. These differences may be attributed to wind-generated noise. In summary, some study results are potentially influenced more by the study design than the device type or ventilator setting. We recommend further research and detailed reporting in the NICU to gain deeper insights into the topic.
format Online
Article
Text
id pubmed-8653757
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-86537572021-12-13 Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations Singh, Devika Fusch, Gerhard Cureus Pediatrics Background and objective Excessive noise in the neonatal intensive care unit (NICU) may lead to serious long-term effects on hearing and sensory development in newborns. As such, the maximum allowed noise level is 45 A-weighted decibels (dBA). Studies regarding noise exposure to ventilated preterm infants show inconsistent results; however, these studies also vary considerably in their methodology in terms of noise ascertainment. We hypothesized that the study methodology can significantly influence data quality when measuring noise levels. In this study, we aimed to investigate whether the variations in ventilator noise levels in NICUs could be a result of methodological differences in study designs. Methods A ventilator circuit was set up using nasal continuous positive airway pressure (nCPAP) and high-frequency (HF) modes with nasal prongs. Noise levels were measured using a commercially calibrated noise meter. Three different scenarios were tested: (1) measurements were taken at different angles (0° to 180°), with 180° facing the end of the nasal prongs, without a mannequin, with the membrane/orifice of the noise meter placed 2 mm laterally from the prongs; (2) noise levels were measured at 180° at distances of 0-20 mm from the nasal prongs; (3) measurements were taken in the oral cavity of a life-size intubation mannequin of a newborn baby. Results Overall, the noise levels produced at different settings varied significantly, ranging from 45.7 dB to 82.2 dB. The average environmental background noise was 44.4 dB. Noise levels typically increased as the angle increased, with the highest noise level recorded at 180° for both HF and nCPAP modes, at 58.4 dB and 58.2 dB, respectively. Noise levels recorded at HF were slightly higher than nCPAP values. Furthermore, with regard to distance, the highest mean value, 82.2 dB, was recorded with the noise meter approximately 3 mm from the nasal prongs, and the lowest mean value, 47.6 dB, was recorded at ~20 mm. During trials with the mannequin, the lowest value, 50.1 dB, was recorded at the entrance of the mouth with slightly higher values being recorded within the oral cavity. Conclusion The results indicate that small changes in experimental settings, such as positioning and distance from the nasal prongs, can greatly influence noise levels, particularly above the recommended levels for neonates. These differences may be attributed to wind-generated noise. In summary, some study results are potentially influenced more by the study design than the device type or ventilator setting. We recommend further research and detailed reporting in the NICU to gain deeper insights into the topic. Cureus 2021-11-08 /pmc/articles/PMC8653757/ /pubmed/34909314 http://dx.doi.org/10.7759/cureus.19353 Text en Copyright © 2021, Singh et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Pediatrics
Singh, Devika
Fusch, Gerhard
Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations
title Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations
title_full Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations
title_fullStr Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations
title_full_unstemmed Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations
title_short Investigating Noise Exposure to Newborn Infants From Respiratory Support: Methodological Considerations
title_sort investigating noise exposure to newborn infants from respiratory support: methodological considerations
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8653757/
https://www.ncbi.nlm.nih.gov/pubmed/34909314
http://dx.doi.org/10.7759/cureus.19353
work_keys_str_mv AT singhdevika investigatingnoiseexposuretonewborninfantsfromrespiratorysupportmethodologicalconsiderations
AT fuschgerhard investigatingnoiseexposuretonewborninfantsfromrespiratorysupportmethodologicalconsiderations