Cargando…

Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis

PURPOSE: The aim of this study was to assess and correlate the stress distribution in an anterior maxillary implant-supported prosthesis with 0°(degree), 15°, and 25° angulated titanium and zirconia abutments using a three-dimensional (3D) finite element analysis (FEA). MATERIALS AND METHODS: Six FE...

Descripción completa

Detalles Bibliográficos
Autores principales: Kapoor, Sumedha, Rodrigues, Shobha, Mahesh, M., Shetty, Thilak, Pai, Umesh, Saldanha, Sharon, Hedge, Puneeth, Shenoy, Satish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8654540/
https://www.ncbi.nlm.nih.gov/pubmed/34899916
http://dx.doi.org/10.1155/2021/9205930
_version_ 1784611882684907520
author Kapoor, Sumedha
Rodrigues, Shobha
Mahesh, M.
Shetty, Thilak
Pai, Umesh
Saldanha, Sharon
Hedge, Puneeth
Shenoy, Satish
author_facet Kapoor, Sumedha
Rodrigues, Shobha
Mahesh, M.
Shetty, Thilak
Pai, Umesh
Saldanha, Sharon
Hedge, Puneeth
Shenoy, Satish
author_sort Kapoor, Sumedha
collection PubMed
description PURPOSE: The aim of this study was to assess and correlate the stress distribution in an anterior maxillary implant-supported prosthesis with 0°(degree), 15°, and 25° angulated titanium and zirconia abutments using a three-dimensional (3D) finite element analysis (FEA). MATERIALS AND METHODS: Six FEA models consisting of a dentate anterior maxilla with a single bone-level implant of dimension 4.2 × 10 mm placed in the region of left maxillary central incisor and abutments of dimension 4.2 mm made of titanium and zirconia each with angulation 0° (IA and IB), 15° (IIA and IIB), and 25° (IIIA and IIIB) and ANSYS Workbench software were utilized to design a layered zirconia crown. Unilateral axial and oblique loads of 178 N were applied on the palatal aspect of the crown of left maxillary central incisor. Average von Mises stress values were evaluated in the implant and the peri-implant bone quantitatively and qualitatively. RESULTS: Stress was shown to increase with an increase in angulation in all the areas that were examined. Zirconia abutments showed lesser stress in the implant and surrounding bone than titanium abutments. When compared with the body and apex of the implant, the implant neck values were higher in all models. In between cortical and cancellous bone, the stress recorded was higher in the cortical bone. CONCLUSION: Within the limitations of this study, straight abutments generated a more uniform and minimal stress in implant and peri-implant bone than angulated abutments. Titanium abutments generated higher stress levels than zirconia abutments. The stresses generated are directly proportional to an increase in abutment angulation, and therefore, straight abutments are most suitable for favourable stress transmission.
format Online
Article
Text
id pubmed-8654540
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-86545402021-12-09 Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis Kapoor, Sumedha Rodrigues, Shobha Mahesh, M. Shetty, Thilak Pai, Umesh Saldanha, Sharon Hedge, Puneeth Shenoy, Satish Int J Dent Research Article PURPOSE: The aim of this study was to assess and correlate the stress distribution in an anterior maxillary implant-supported prosthesis with 0°(degree), 15°, and 25° angulated titanium and zirconia abutments using a three-dimensional (3D) finite element analysis (FEA). MATERIALS AND METHODS: Six FEA models consisting of a dentate anterior maxilla with a single bone-level implant of dimension 4.2 × 10 mm placed in the region of left maxillary central incisor and abutments of dimension 4.2 mm made of titanium and zirconia each with angulation 0° (IA and IB), 15° (IIA and IIB), and 25° (IIIA and IIIB) and ANSYS Workbench software were utilized to design a layered zirconia crown. Unilateral axial and oblique loads of 178 N were applied on the palatal aspect of the crown of left maxillary central incisor. Average von Mises stress values were evaluated in the implant and the peri-implant bone quantitatively and qualitatively. RESULTS: Stress was shown to increase with an increase in angulation in all the areas that were examined. Zirconia abutments showed lesser stress in the implant and surrounding bone than titanium abutments. When compared with the body and apex of the implant, the implant neck values were higher in all models. In between cortical and cancellous bone, the stress recorded was higher in the cortical bone. CONCLUSION: Within the limitations of this study, straight abutments generated a more uniform and minimal stress in implant and peri-implant bone than angulated abutments. Titanium abutments generated higher stress levels than zirconia abutments. The stresses generated are directly proportional to an increase in abutment angulation, and therefore, straight abutments are most suitable for favourable stress transmission. Hindawi 2021-12-01 /pmc/articles/PMC8654540/ /pubmed/34899916 http://dx.doi.org/10.1155/2021/9205930 Text en Copyright © 2021 Sumedha Kapoor et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kapoor, Sumedha
Rodrigues, Shobha
Mahesh, M.
Shetty, Thilak
Pai, Umesh
Saldanha, Sharon
Hedge, Puneeth
Shenoy, Satish
Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis
title Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis
title_full Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis
title_fullStr Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis
title_full_unstemmed Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis
title_short Evaluation of Stress Generated with Different Abutment Materials and Angulations under Axial and Oblique Loading in the Anterior Maxilla: Three-Dimensional Finite Element Analysis
title_sort evaluation of stress generated with different abutment materials and angulations under axial and oblique loading in the anterior maxilla: three-dimensional finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8654540/
https://www.ncbi.nlm.nih.gov/pubmed/34899916
http://dx.doi.org/10.1155/2021/9205930
work_keys_str_mv AT kapoorsumedha evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT rodriguesshobha evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT maheshm evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT shettythilak evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT paiumesh evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT saldanhasharon evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT hedgepuneeth evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis
AT shenoysatish evaluationofstressgeneratedwithdifferentabutmentmaterialsandangulationsunderaxialandobliqueloadingintheanteriormaxillathreedimensionalfiniteelementanalysis