Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy
Recently, noncontact vital sign monitors have attracted attention because of issues related to the transmission of contagious diseases. We developed a real-time vital sign monitor using impulse-radio ultrawideband (IR-UWB) radar with embedded processors and software; we then evaluated its accuracy i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655004/ https://www.ncbi.nlm.nih.gov/pubmed/34880335 http://dx.doi.org/10.1038/s41598-021-03069-2 |
_version_ | 1784611990190161920 |
---|---|
author | Park, Jun-Young Lee, Yonggu Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo |
author_facet | Park, Jun-Young Lee, Yonggu Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo |
author_sort | Park, Jun-Young |
collection | PubMed |
description | Recently, noncontact vital sign monitors have attracted attention because of issues related to the transmission of contagious diseases. We developed a real-time vital sign monitor using impulse-radio ultrawideband (IR-UWB) radar with embedded processors and software; we then evaluated its accuracy in measuring heart rate (HR) and respiratory rate (RR) and investigated the factors affecting the accuracy of the radar-based measurements. In 50 patients visiting a cardiology clinic, HR and RR were measured using IR-UWB radar simultaneously with electrocardiography and capnometry. All patients underwent HR and RR measurements in 2 postures—supine and sitting—for 2 min each. There was a high agreement between the RR measured using radar and capnometry (concordance correlation coefficient [CCC] 0.925 [0.919–0.926]; upper and lower limits of agreement [LOA], − 2.21 and 3.90 breaths/min). The HR measured using radar was also in close agreement with the value measured using electrocardiography (CCC 0.749 [0.738–0.760]; upper and lower LOA, − 12.78 and 15.04 beats/min). Linear mixed effect models showed that the sitting position and an HR < 70 bpm were associated with an increase in the absolute biases of the HR, whereas the sitting position and an RR < 18 breaths/min were associated with an increase in the absolute biases of the RR. The IR-UWB radar sensor with embedded processors and software can measure the RR and HR in real time with high precision. The sitting position and a low RR or HR were associated with the accuracy of RR and HR measurement, respectively, using IR-UWB radar. |
format | Online Article Text |
id | pubmed-8655004 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-86550042021-12-09 Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy Park, Jun-Young Lee, Yonggu Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo Sci Rep Article Recently, noncontact vital sign monitors have attracted attention because of issues related to the transmission of contagious diseases. We developed a real-time vital sign monitor using impulse-radio ultrawideband (IR-UWB) radar with embedded processors and software; we then evaluated its accuracy in measuring heart rate (HR) and respiratory rate (RR) and investigated the factors affecting the accuracy of the radar-based measurements. In 50 patients visiting a cardiology clinic, HR and RR were measured using IR-UWB radar simultaneously with electrocardiography and capnometry. All patients underwent HR and RR measurements in 2 postures—supine and sitting—for 2 min each. There was a high agreement between the RR measured using radar and capnometry (concordance correlation coefficient [CCC] 0.925 [0.919–0.926]; upper and lower limits of agreement [LOA], − 2.21 and 3.90 breaths/min). The HR measured using radar was also in close agreement with the value measured using electrocardiography (CCC 0.749 [0.738–0.760]; upper and lower LOA, − 12.78 and 15.04 beats/min). Linear mixed effect models showed that the sitting position and an HR < 70 bpm were associated with an increase in the absolute biases of the HR, whereas the sitting position and an RR < 18 breaths/min were associated with an increase in the absolute biases of the RR. The IR-UWB radar sensor with embedded processors and software can measure the RR and HR in real time with high precision. The sitting position and a low RR or HR were associated with the accuracy of RR and HR measurement, respectively, using IR-UWB radar. Nature Publishing Group UK 2021-12-08 /pmc/articles/PMC8655004/ /pubmed/34880335 http://dx.doi.org/10.1038/s41598-021-03069-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Park, Jun-Young Lee, Yonggu Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy |
title | Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy |
title_full | Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy |
title_fullStr | Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy |
title_full_unstemmed | Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy |
title_short | Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy |
title_sort | preclinical evaluation of noncontact vital signs monitoring using real-time ir-uwb radar and factors affecting its accuracy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655004/ https://www.ncbi.nlm.nih.gov/pubmed/34880335 http://dx.doi.org/10.1038/s41598-021-03069-2 |
work_keys_str_mv | AT parkjunyoung preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy AT leeyonggu preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy AT heoran preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy AT parkhyunkyung preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy AT choseokhyun preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy AT chosungho preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy AT limyounghyo preclinicalevaluationofnoncontactvitalsignsmonitoringusingrealtimeiruwbradarandfactorsaffectingitsaccuracy |