Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma

PURPOSE: To compare the dosimetric differences in stereotactic radiosurgery between use of passively scattered protons (PSRS) versus photons (XSRS) for pituitary adenomas. METHODS AND MATERIALS: Nine patients with pituitary adenomas were selected among patients receiving single-fraction proton stere...

Descripción completa

Detalles Bibliográficos
Autores principales: Sud, Shivani, Botticello, Thomas, Niemierko, Andrzej, Daly, Jillian, Bussiere, Marc, Shih, Helen A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655425/
https://www.ncbi.nlm.nih.gov/pubmed/34934865
http://dx.doi.org/10.1016/j.adro.2021.100806
_version_ 1784612070978748416
author Sud, Shivani
Botticello, Thomas
Niemierko, Andrzej
Daly, Jillian
Bussiere, Marc
Shih, Helen A
author_facet Sud, Shivani
Botticello, Thomas
Niemierko, Andrzej
Daly, Jillian
Bussiere, Marc
Shih, Helen A
author_sort Sud, Shivani
collection PubMed
description PURPOSE: To compare the dosimetric differences in stereotactic radiosurgery between use of passively scattered protons (PSRS) versus photons (XSRS) for pituitary adenomas. METHODS AND MATERIALS: Nine patients with pituitary adenomas were selected among patients receiving single-fraction proton stereotactic radiosurgery (PSRS) between 2016 and 2017. These cases were replanned with XSRS using volumetric-modulated arc therapy with 2.5 mm and 5 mm multileaf collimators (2.5XSRS and 5XSRS, respectively). PSRS was planned with a dedicated single scattering stereotactic proton unit delivered via 3 equally or unequally weighted isocentric fields. XSRS plans were created with optimization to spare organs at risk. Plans were generated using the original total treatment dose delivered in 1 fraction. RESULTS: Plans were evaluated for target volume dosimetry and estimated clinical toxicity. There was no significant difference in clinical target volume V100%, V95%, V90% or homogeneity index between treatment modalities. PSRS offered lower maximum dose (Dmax) to organs at risk and equivalent uniform dose (EUD) compared with 5XSRS and 2.5XSRS, respectively, for critical structures including optic nerve (right, Dmax 4.18, 5.32, 5.41; EUD 3.35, 4.08, 4.20) and hypothalamus (Dmax 1.71, 3.94, 3.77; EUD 0.94, 2.47, 2.39; P < .05 for PSRS vs 5XSRS and 2.5XSRS). The projected risk of secondary tumors in excess of baseline was lowest for PSRS plans (PSRS 5.28, 5XSRS 12.93, 2.5XSRS 12.66 cases per 10,000 patient-years; P = .008 for PSRS vs 5XSRS, PSRS vs 2.5XSRS, and P = .77 for 5XSRS vs 2.5XSRS). CONCLUSIONS: We demonstrate that neither modality has empirically superior dosimetry and identify potential clinical advantages as well as limitations of each technique. PSRS, 5XSRS and 2.5XSRS demonstrate comparable target volume dosimetry for pituitary adenoma. PSRS compared with XSRS modalities offers modestly decreased maximum dose and EUD to critical proximal structures and decreases risk of radiation-induced secondary tumors by more than half.
format Online
Article
Text
id pubmed-8655425
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86554252021-12-20 Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma Sud, Shivani Botticello, Thomas Niemierko, Andrzej Daly, Jillian Bussiere, Marc Shih, Helen A Adv Radiat Oncol Scientific Article PURPOSE: To compare the dosimetric differences in stereotactic radiosurgery between use of passively scattered protons (PSRS) versus photons (XSRS) for pituitary adenomas. METHODS AND MATERIALS: Nine patients with pituitary adenomas were selected among patients receiving single-fraction proton stereotactic radiosurgery (PSRS) between 2016 and 2017. These cases were replanned with XSRS using volumetric-modulated arc therapy with 2.5 mm and 5 mm multileaf collimators (2.5XSRS and 5XSRS, respectively). PSRS was planned with a dedicated single scattering stereotactic proton unit delivered via 3 equally or unequally weighted isocentric fields. XSRS plans were created with optimization to spare organs at risk. Plans were generated using the original total treatment dose delivered in 1 fraction. RESULTS: Plans were evaluated for target volume dosimetry and estimated clinical toxicity. There was no significant difference in clinical target volume V100%, V95%, V90% or homogeneity index between treatment modalities. PSRS offered lower maximum dose (Dmax) to organs at risk and equivalent uniform dose (EUD) compared with 5XSRS and 2.5XSRS, respectively, for critical structures including optic nerve (right, Dmax 4.18, 5.32, 5.41; EUD 3.35, 4.08, 4.20) and hypothalamus (Dmax 1.71, 3.94, 3.77; EUD 0.94, 2.47, 2.39; P < .05 for PSRS vs 5XSRS and 2.5XSRS). The projected risk of secondary tumors in excess of baseline was lowest for PSRS plans (PSRS 5.28, 5XSRS 12.93, 2.5XSRS 12.66 cases per 10,000 patient-years; P = .008 for PSRS vs 5XSRS, PSRS vs 2.5XSRS, and P = .77 for 5XSRS vs 2.5XSRS). CONCLUSIONS: We demonstrate that neither modality has empirically superior dosimetry and identify potential clinical advantages as well as limitations of each technique. PSRS, 5XSRS and 2.5XSRS demonstrate comparable target volume dosimetry for pituitary adenoma. PSRS compared with XSRS modalities offers modestly decreased maximum dose and EUD to critical proximal structures and decreases risk of radiation-induced secondary tumors by more than half. Elsevier 2021-09-17 /pmc/articles/PMC8655425/ /pubmed/34934865 http://dx.doi.org/10.1016/j.adro.2021.100806 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Scientific Article
Sud, Shivani
Botticello, Thomas
Niemierko, Andrzej
Daly, Jillian
Bussiere, Marc
Shih, Helen A
Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
title Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
title_full Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
title_fullStr Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
title_full_unstemmed Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
title_short Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
title_sort dosimetric comparison of proton versus photon radiosurgery for treatment of pituitary adenoma
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655425/
https://www.ncbi.nlm.nih.gov/pubmed/34934865
http://dx.doi.org/10.1016/j.adro.2021.100806
work_keys_str_mv AT sudshivani dosimetriccomparisonofprotonversusphotonradiosurgeryfortreatmentofpituitaryadenoma
AT botticellothomas dosimetriccomparisonofprotonversusphotonradiosurgeryfortreatmentofpituitaryadenoma
AT niemierkoandrzej dosimetriccomparisonofprotonversusphotonradiosurgeryfortreatmentofpituitaryadenoma
AT dalyjillian dosimetriccomparisonofprotonversusphotonradiosurgeryfortreatmentofpituitaryadenoma
AT bussieremarc dosimetriccomparisonofprotonversusphotonradiosurgeryfortreatmentofpituitaryadenoma
AT shihhelena dosimetriccomparisonofprotonversusphotonradiosurgeryfortreatmentofpituitaryadenoma