Cargando…
Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique
INTRODUCTION: Peripherally inserted central catheters (PICCs) offer a convenient long‐term intravenous access option. Different methods exist for insertion including the use of continuous fluoroscopy for guidance, or bedside insertion techniques. The blind pushing technique is a bedside approach whi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655624/ https://www.ncbi.nlm.nih.gov/pubmed/34343419 http://dx.doi.org/10.1002/jmrs.533 |
_version_ | 1784612112764502016 |
---|---|
author | Erskine, Brendan Bradley, Pierre Joseph, Tim Yeh, Sabrina Clements, Warren |
author_facet | Erskine, Brendan Bradley, Pierre Joseph, Tim Yeh, Sabrina Clements, Warren |
author_sort | Erskine, Brendan |
collection | PubMed |
description | INTRODUCTION: Peripherally inserted central catheters (PICCs) offer a convenient long‐term intravenous access option. Different methods exist for insertion including the use of continuous fluoroscopy for guidance, or bedside insertion techniques. The blind pushing technique is a bedside approach which involves advancing a PICC through the access sheath without imaging guidance, before taking a mobile chest radiograph to confirm tip position. Obtaining optimal position is a critical aim of PICC placement as malpositioned lines have been associated with higher complications including death. We aimed to assess the accuracy of PICC placement by comparing the tip position and complications for lines placed under fluoroscopic guidance to those placed without fluoroscopic guidance. METHODS: The Radiology Information System was used to identify 100 continuous PICC insertions in each group (fluoroscopic and blind pushing) between 1 January and 12 May 2019. Patients were excluded if there was a known history of central venous occlusion/stenosis. RESULTS: In the fluoroscopic‐guided group, 0% of the lines were malpositioned compared with 60% of the lines placed using the blind pushing technique, P < 0.001. Fluoroscopic‐guided PICC insertions were in place for a total of 2446 days and demonstrated 6 complications (2.45 complications per 1000 catheter days). This compared with blind pushing technique PICC insertions which were in place for a total of 1521 days and demonstrated 18 complications (11.83 complications per 1000 catheter days), P = 0.004. CONCLUSION: The use of fluoroscopy for PICC placement leads to significant improvements in tip accuracy than for PICCs placed using the blind pushing technique. While the use of these imaging resources incurs cost and time, these factors should be balanced in order to offer patients the safest and most accurate method of line insertion. |
format | Online Article Text |
id | pubmed-8655624 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86556242021-12-20 Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique Erskine, Brendan Bradley, Pierre Joseph, Tim Yeh, Sabrina Clements, Warren J Med Radiat Sci Original Articles INTRODUCTION: Peripherally inserted central catheters (PICCs) offer a convenient long‐term intravenous access option. Different methods exist for insertion including the use of continuous fluoroscopy for guidance, or bedside insertion techniques. The blind pushing technique is a bedside approach which involves advancing a PICC through the access sheath without imaging guidance, before taking a mobile chest radiograph to confirm tip position. Obtaining optimal position is a critical aim of PICC placement as malpositioned lines have been associated with higher complications including death. We aimed to assess the accuracy of PICC placement by comparing the tip position and complications for lines placed under fluoroscopic guidance to those placed without fluoroscopic guidance. METHODS: The Radiology Information System was used to identify 100 continuous PICC insertions in each group (fluoroscopic and blind pushing) between 1 January and 12 May 2019. Patients were excluded if there was a known history of central venous occlusion/stenosis. RESULTS: In the fluoroscopic‐guided group, 0% of the lines were malpositioned compared with 60% of the lines placed using the blind pushing technique, P < 0.001. Fluoroscopic‐guided PICC insertions were in place for a total of 2446 days and demonstrated 6 complications (2.45 complications per 1000 catheter days). This compared with blind pushing technique PICC insertions which were in place for a total of 1521 days and demonstrated 18 complications (11.83 complications per 1000 catheter days), P = 0.004. CONCLUSION: The use of fluoroscopy for PICC placement leads to significant improvements in tip accuracy than for PICCs placed using the blind pushing technique. While the use of these imaging resources incurs cost and time, these factors should be balanced in order to offer patients the safest and most accurate method of line insertion. John Wiley and Sons Inc. 2021-08-03 2021-12 /pmc/articles/PMC8655624/ /pubmed/34343419 http://dx.doi.org/10.1002/jmrs.533 Text en © 2021 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Erskine, Brendan Bradley, Pierre Joseph, Tim Yeh, Sabrina Clements, Warren Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique |
title | Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique |
title_full | Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique |
title_fullStr | Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique |
title_full_unstemmed | Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique |
title_short | Comparing the accuracy and complications of peripherally inserted central catheter (PICC) placement using fluoroscopic and the blind pushing technique |
title_sort | comparing the accuracy and complications of peripherally inserted central catheter (picc) placement using fluoroscopic and the blind pushing technique |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655624/ https://www.ncbi.nlm.nih.gov/pubmed/34343419 http://dx.doi.org/10.1002/jmrs.533 |
work_keys_str_mv | AT erskinebrendan comparingtheaccuracyandcomplicationsofperipherallyinsertedcentralcatheterpiccplacementusingfluoroscopicandtheblindpushingtechnique AT bradleypierre comparingtheaccuracyandcomplicationsofperipherallyinsertedcentralcatheterpiccplacementusingfluoroscopicandtheblindpushingtechnique AT josephtim comparingtheaccuracyandcomplicationsofperipherallyinsertedcentralcatheterpiccplacementusingfluoroscopicandtheblindpushingtechnique AT yehsabrina comparingtheaccuracyandcomplicationsofperipherallyinsertedcentralcatheterpiccplacementusingfluoroscopicandtheblindpushingtechnique AT clementswarren comparingtheaccuracyandcomplicationsofperipherallyinsertedcentralcatheterpiccplacementusingfluoroscopicandtheblindpushingtechnique |