Cargando…

Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography

Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT). Methods: Macular and optic disc volumetric measurements were performed with individual and...

Descripción completa

Detalles Bibliográficos
Autores principales: Domínguez-Vicent, Alberto, Kensén, Jesper, Ramsay, Marika Wahlberg, Brautaset, Rune, Venkataraman, Abinaya Priya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655734/
https://www.ncbi.nlm.nih.gov/pubmed/34901081
http://dx.doi.org/10.3389/fmed.2021.764236
_version_ 1784612133357486080
author Domínguez-Vicent, Alberto
Kensén, Jesper
Ramsay, Marika Wahlberg
Brautaset, Rune
Venkataraman, Abinaya Priya
author_facet Domínguez-Vicent, Alberto
Kensén, Jesper
Ramsay, Marika Wahlberg
Brautaset, Rune
Venkataraman, Abinaya Priya
author_sort Domínguez-Vicent, Alberto
collection PubMed
description Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT). Methods: Macular and optic disc volumetric measurements were performed with individual and combined scan protocols in one eye of 75 healthy subjects. Three repeated measurements were performed with each protocol. From the macular area, retinal thickness in nine different sectors and ganglion cell complex thickness in eight different sectors were analyzed from both scan modes. From the optic disc area, the peripapillary retinal nerve fiber layer (pRNFL) thickness in 12 clock sectors and the optic disc parameters were evaluated. For all the parameters, repeatability limit and agreement analysis were performed. Results: For the retinal thickness measurements in macula, the combined scan had two to three times larger repeatability limit than the individual scan for all the sectors except the central sector, where the repeatability limit was five times larger. The limits of agreement intervals were lower than 20 μm for all sectors, except the central. The ganglion cell complex measurements also had larger repeatability limits for the combined scans, and the limits of agreement intervals were <10 μm for all sectors. For the pRNFL thickness, the repeatability values were distributed like a vertically elongated ellipse for both scans, but still the repeatability was better for individual scan compared to the combined scan. The shortest and widest interval are obtained for sectors 9 (9 μm) and 12 (40 μm), respectively. The repeatability limit was <0.15 units for all disc parameters with both scan modes. Conclusion: The individual macula and optic disc scans had better repeatability than the combined scan mode, and the two scan modes cannot be used interchangeability due to the wide limits of agreement.
format Online
Article
Text
id pubmed-8655734
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86557342021-12-10 Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography Domínguez-Vicent, Alberto Kensén, Jesper Ramsay, Marika Wahlberg Brautaset, Rune Venkataraman, Abinaya Priya Front Med (Lausanne) Medicine Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT). Methods: Macular and optic disc volumetric measurements were performed with individual and combined scan protocols in one eye of 75 healthy subjects. Three repeated measurements were performed with each protocol. From the macular area, retinal thickness in nine different sectors and ganglion cell complex thickness in eight different sectors were analyzed from both scan modes. From the optic disc area, the peripapillary retinal nerve fiber layer (pRNFL) thickness in 12 clock sectors and the optic disc parameters were evaluated. For all the parameters, repeatability limit and agreement analysis were performed. Results: For the retinal thickness measurements in macula, the combined scan had two to three times larger repeatability limit than the individual scan for all the sectors except the central sector, where the repeatability limit was five times larger. The limits of agreement intervals were lower than 20 μm for all sectors, except the central. The ganglion cell complex measurements also had larger repeatability limits for the combined scans, and the limits of agreement intervals were <10 μm for all sectors. For the pRNFL thickness, the repeatability values were distributed like a vertically elongated ellipse for both scans, but still the repeatability was better for individual scan compared to the combined scan. The shortest and widest interval are obtained for sectors 9 (9 μm) and 12 (40 μm), respectively. The repeatability limit was <0.15 units for all disc parameters with both scan modes. Conclusion: The individual macula and optic disc scans had better repeatability than the combined scan mode, and the two scan modes cannot be used interchangeability due to the wide limits of agreement. Frontiers Media S.A. 2021-11-25 /pmc/articles/PMC8655734/ /pubmed/34901081 http://dx.doi.org/10.3389/fmed.2021.764236 Text en Copyright © 2021 Domínguez-Vicent, Kensén, Ramsay, Brautaset and Venkataraman. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Domínguez-Vicent, Alberto
Kensén, Jesper
Ramsay, Marika Wahlberg
Brautaset, Rune
Venkataraman, Abinaya Priya
Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
title Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
title_full Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
title_fullStr Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
title_full_unstemmed Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
title_short Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
title_sort precision and agreement of individual and simultaneous macular and optic disc volumetric measurements with spectral domain optical coherence tomography
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655734/
https://www.ncbi.nlm.nih.gov/pubmed/34901081
http://dx.doi.org/10.3389/fmed.2021.764236
work_keys_str_mv AT dominguezvicentalberto precisionandagreementofindividualandsimultaneousmacularandopticdiscvolumetricmeasurementswithspectraldomainopticalcoherencetomography
AT kensenjesper precisionandagreementofindividualandsimultaneousmacularandopticdiscvolumetricmeasurementswithspectraldomainopticalcoherencetomography
AT ramsaymarikawahlberg precisionandagreementofindividualandsimultaneousmacularandopticdiscvolumetricmeasurementswithspectraldomainopticalcoherencetomography
AT brautasetrune precisionandagreementofindividualandsimultaneousmacularandopticdiscvolumetricmeasurementswithspectraldomainopticalcoherencetomography
AT venkataramanabinayapriya precisionandagreementofindividualandsimultaneousmacularandopticdiscvolumetricmeasurementswithspectraldomainopticalcoherencetomography