Cargando…

Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study

Wearable health monitoring systems that collect data in free-living environments are becoming increasingly popular. Flexible printed circuits provide a commercially available option that can conform to the shape of a wearable system and support electronic sensing and flexible interconnect. However,...

Descripción completa

Detalles Bibliográficos
Autores principales: CRITCHER, SHELBY, FREEBORN, TODD J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8656411/
https://www.ncbi.nlm.nih.gov/pubmed/34901875
http://dx.doi.org/10.1109/OJCAS.2021.3122369
_version_ 1784612275408076800
author CRITCHER, SHELBY
FREEBORN, TODD J.
author_facet CRITCHER, SHELBY
FREEBORN, TODD J.
author_sort CRITCHER, SHELBY
collection PubMed
description Wearable health monitoring systems that collect data in free-living environments are becoming increasingly popular. Flexible printed circuits provide a commercially available option that can conform to the shape of a wearable system and support electronic sensing and flexible interconnect. However, repetitive dynamic activity can stress and damage the interconnect of flexible PCBs which degrades data quality. This case study evaluated the performance of flexible PCBs providing interconnect between electrodes and sensing electronics for tissue bioimpedance measurements in a wearable system. Resistance data (1 kHz to 128 kHz) was collected from localized knee tissues of 3 participants using the wearable design with flexible PCBs over 7 days of free-living. From electrical and optical inspection after use trace cracking of the flexible PCBs occurred, degrading tissue resistances reported by the wearable system. Exploration of these results advances understanding of how flexible PCBs perform in free-living conditions for wearable bioimpedance applications.
format Online
Article
Text
id pubmed-8656411
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-86564112021-12-09 Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study CRITCHER, SHELBY FREEBORN, TODD J. IEEE Open J Circuits Syst Article Wearable health monitoring systems that collect data in free-living environments are becoming increasingly popular. Flexible printed circuits provide a commercially available option that can conform to the shape of a wearable system and support electronic sensing and flexible interconnect. However, repetitive dynamic activity can stress and damage the interconnect of flexible PCBs which degrades data quality. This case study evaluated the performance of flexible PCBs providing interconnect between electrodes and sensing electronics for tissue bioimpedance measurements in a wearable system. Resistance data (1 kHz to 128 kHz) was collected from localized knee tissues of 3 participants using the wearable design with flexible PCBs over 7 days of free-living. From electrical and optical inspection after use trace cracking of the flexible PCBs occurred, degrading tissue resistances reported by the wearable system. Exploration of these results advances understanding of how flexible PCBs perform in free-living conditions for wearable bioimpedance applications. 2021-11-24 2021 /pmc/articles/PMC8656411/ /pubmed/34901875 http://dx.doi.org/10.1109/OJCAS.2021.3122369 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
CRITCHER, SHELBY
FREEBORN, TODD J.
Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study
title Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study
title_full Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study
title_fullStr Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study
title_full_unstemmed Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study
title_short Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study
title_sort flexible pcb failures from dynamic activity and their impacts on bioimpedance measurements: a wearable case study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8656411/
https://www.ncbi.nlm.nih.gov/pubmed/34901875
http://dx.doi.org/10.1109/OJCAS.2021.3122369
work_keys_str_mv AT critchershelby flexiblepcbfailuresfromdynamicactivityandtheirimpactsonbioimpedancemeasurementsawearablecasestudy
AT freeborntoddj flexiblepcbfailuresfromdynamicactivityandtheirimpactsonbioimpedancemeasurementsawearablecasestudy