Cargando…
The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring
From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynch...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658316/ https://www.ncbi.nlm.nih.gov/pubmed/34884329 http://dx.doi.org/10.3390/jcm10235626 |
_version_ | 1784612702493081600 |
---|---|
author | Diemberger, Igor Vicentini, Alessandro Cattafi, Giuseppe Ziacchi, Matteo Iacopino, Saverio Morani, Giovanni Pisanò, Ennio Molon, Giulio Giovannini, Tiziana Russo, Antonio Dello Boriani, Giuseppe Bertaglia, Emanuele Biffi, Mauro Bongiorni, Maria Grazia Rordorf, Roberto Zucchelli, Giulio |
author_facet | Diemberger, Igor Vicentini, Alessandro Cattafi, Giuseppe Ziacchi, Matteo Iacopino, Saverio Morani, Giovanni Pisanò, Ennio Molon, Giulio Giovannini, Tiziana Russo, Antonio Dello Boriani, Giuseppe Bertaglia, Emanuele Biffi, Mauro Bongiorni, Maria Grazia Rordorf, Roberto Zucchelli, Giulio |
author_sort | Diemberger, Igor |
collection | PubMed |
description | From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year. We analyzed device data of the period 9 March 2019–31 May 2020 of remotely monitored patients from 34 Italian centers. Patients were also categorized according to areas with high/low infection prevalence. Among 696 patients, we observed a significant drop in median activity in LDP as compared to CP that significantly increased in the PLDP, but well below CP (all p < 0.0001). The median day heart rate and heart rate variability showed a similar trend. This behavior was associated during LDP with a significant increase in the burden of atrial arrhythmias (p = 0.0150 versus CP) and of ventricular arrhythmias [6.6 vs. 1.5 per 100 patient-weeks in CP; p = 0.0026]; the latter decreased in PLDP [0.3 per 100 patient-weeks; p = 0.0035 vs. LDP]. No modifications were recorded in thoracic fluid levels. The high/low prevalence of COVID-19 infection had no significant impact. We found an increase in the arrhythmic burden in LDP coupled with a decrease in physical activity and heart rate variability, without significant modifications of transthoracic impedance, independent from COVID-19 infection prevalence. These findings suggest a negative impact of the COVID-19 pandemic, probably related to lockdown restrictions. |
format | Online Article Text |
id | pubmed-8658316 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86583162021-12-10 The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring Diemberger, Igor Vicentini, Alessandro Cattafi, Giuseppe Ziacchi, Matteo Iacopino, Saverio Morani, Giovanni Pisanò, Ennio Molon, Giulio Giovannini, Tiziana Russo, Antonio Dello Boriani, Giuseppe Bertaglia, Emanuele Biffi, Mauro Bongiorni, Maria Grazia Rordorf, Roberto Zucchelli, Giulio J Clin Med Article From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year. We analyzed device data of the period 9 March 2019–31 May 2020 of remotely monitored patients from 34 Italian centers. Patients were also categorized according to areas with high/low infection prevalence. Among 696 patients, we observed a significant drop in median activity in LDP as compared to CP that significantly increased in the PLDP, but well below CP (all p < 0.0001). The median day heart rate and heart rate variability showed a similar trend. This behavior was associated during LDP with a significant increase in the burden of atrial arrhythmias (p = 0.0150 versus CP) and of ventricular arrhythmias [6.6 vs. 1.5 per 100 patient-weeks in CP; p = 0.0026]; the latter decreased in PLDP [0.3 per 100 patient-weeks; p = 0.0035 vs. LDP]. No modifications were recorded in thoracic fluid levels. The high/low prevalence of COVID-19 infection had no significant impact. We found an increase in the arrhythmic burden in LDP coupled with a decrease in physical activity and heart rate variability, without significant modifications of transthoracic impedance, independent from COVID-19 infection prevalence. These findings suggest a negative impact of the COVID-19 pandemic, probably related to lockdown restrictions. MDPI 2021-11-29 /pmc/articles/PMC8658316/ /pubmed/34884329 http://dx.doi.org/10.3390/jcm10235626 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Diemberger, Igor Vicentini, Alessandro Cattafi, Giuseppe Ziacchi, Matteo Iacopino, Saverio Morani, Giovanni Pisanò, Ennio Molon, Giulio Giovannini, Tiziana Russo, Antonio Dello Boriani, Giuseppe Bertaglia, Emanuele Biffi, Mauro Bongiorni, Maria Grazia Rordorf, Roberto Zucchelli, Giulio The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring |
title | The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring |
title_full | The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring |
title_fullStr | The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring |
title_full_unstemmed | The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring |
title_short | The Impact of COVID-19 Pandemic and Lockdown Restrictions on Cardiac Implantable Device Recipients with Remote Monitoring |
title_sort | impact of covid-19 pandemic and lockdown restrictions on cardiac implantable device recipients with remote monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658316/ https://www.ncbi.nlm.nih.gov/pubmed/34884329 http://dx.doi.org/10.3390/jcm10235626 |
work_keys_str_mv | AT diembergerigor theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT vicentinialessandro theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT cattafigiuseppe theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT ziacchimatteo theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT iacopinosaverio theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT moranigiovanni theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT pisanoennio theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT molongiulio theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT giovanninitiziana theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT russoantoniodello theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT borianigiuseppe theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT bertagliaemanuele theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT biffimauro theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT bongiornimariagrazia theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT rordorfroberto theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT zucchelligiulio theimpactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT diembergerigor impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT vicentinialessandro impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT cattafigiuseppe impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT ziacchimatteo impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT iacopinosaverio impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT moranigiovanni impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT pisanoennio impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT molongiulio impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT giovanninitiziana impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT russoantoniodello impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT borianigiuseppe impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT bertagliaemanuele impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT biffimauro impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT bongiornimariagrazia impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT rordorfroberto impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring AT zucchelligiulio impactofcovid19pandemicandlockdownrestrictionsoncardiacimplantabledevicerecipientswithremotemonitoring |