Cargando…
A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer
Utility poles made of glass fibre-reinforced polymer (GFRP) are becoming increasingly common in European countries. Therefore, it is necessary to accurately examine their structural properties to ensure the integrity and safety of the poles. The purpose of this article is to compare the bending resi...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658435/ https://www.ncbi.nlm.nih.gov/pubmed/34885548 http://dx.doi.org/10.3390/ma14237398 |
_version_ | 1784612731963310080 |
---|---|
author | Broniewicz, Mirosław Broniewicz, Filip Broniewicz, Elżbieta |
author_facet | Broniewicz, Mirosław Broniewicz, Filip Broniewicz, Elżbieta |
author_sort | Broniewicz, Mirosław |
collection | PubMed |
description | Utility poles made of glass fibre-reinforced polymer (GFRP) are becoming increasingly common in European countries. Therefore, it is necessary to accurately examine their structural properties to ensure the integrity and safety of the poles. The purpose of this article is to compare the bending resistance of GFRP composite lighting columns obtained using European standard procedures with full-scale experimental tests. Several composite lighting columns were tested as part of the research study, and coupon tests were performed to assess the material properties required to calculate their bending resistance according to European Standard (EN) 40-3-3. The results obtained differed significantly. Furthermore, it was observed that the current standard rules for obtaining the resistance of GFRP poles based on the limit state method show a higher load capacity of the column in comparison to the capacity obtained from the tests. |
format | Online Article Text |
id | pubmed-8658435 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86584352021-12-10 A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer Broniewicz, Mirosław Broniewicz, Filip Broniewicz, Elżbieta Materials (Basel) Article Utility poles made of glass fibre-reinforced polymer (GFRP) are becoming increasingly common in European countries. Therefore, it is necessary to accurately examine their structural properties to ensure the integrity and safety of the poles. The purpose of this article is to compare the bending resistance of GFRP composite lighting columns obtained using European standard procedures with full-scale experimental tests. Several composite lighting columns were tested as part of the research study, and coupon tests were performed to assess the material properties required to calculate their bending resistance according to European Standard (EN) 40-3-3. The results obtained differed significantly. Furthermore, it was observed that the current standard rules for obtaining the resistance of GFRP poles based on the limit state method show a higher load capacity of the column in comparison to the capacity obtained from the tests. MDPI 2021-12-02 /pmc/articles/PMC8658435/ /pubmed/34885548 http://dx.doi.org/10.3390/ma14237398 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Broniewicz, Mirosław Broniewicz, Filip Broniewicz, Elżbieta A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer |
title | A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer |
title_full | A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer |
title_fullStr | A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer |
title_full_unstemmed | A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer |
title_short | A Full-Scale Experimental Investigation of Utility Poles Made of Glass Fibre Reinforced Polymer |
title_sort | full-scale experimental investigation of utility poles made of glass fibre reinforced polymer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658435/ https://www.ncbi.nlm.nih.gov/pubmed/34885548 http://dx.doi.org/10.3390/ma14237398 |
work_keys_str_mv | AT broniewiczmirosław afullscaleexperimentalinvestigationofutilitypolesmadeofglassfibrereinforcedpolymer AT broniewiczfilip afullscaleexperimentalinvestigationofutilitypolesmadeofglassfibrereinforcedpolymer AT broniewiczelzbieta afullscaleexperimentalinvestigationofutilitypolesmadeofglassfibrereinforcedpolymer AT broniewiczmirosław fullscaleexperimentalinvestigationofutilitypolesmadeofglassfibrereinforcedpolymer AT broniewiczfilip fullscaleexperimentalinvestigationofutilitypolesmadeofglassfibrereinforcedpolymer AT broniewiczelzbieta fullscaleexperimentalinvestigationofutilitypolesmadeofglassfibrereinforcedpolymer |