Cargando…
The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT
A three-dimensional (3D) finite element (FE) model of the mandibular bone was created from 3D X-ray CT scan images of a live human subject. Simulating the clinical situation of implant therapy at the mandibular first molar, virtual extraction of the tooth was performed at the 3D FE mandibular model,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658520/ https://www.ncbi.nlm.nih.gov/pubmed/34885508 http://dx.doi.org/10.3390/ma14237344 |
_version_ | 1784612752245915648 |
---|---|
author | Shinya, Akikazu Ishida, Yoshiki Miura, Daisuke Shinya, Akiyoshi |
author_facet | Shinya, Akikazu Ishida, Yoshiki Miura, Daisuke Shinya, Akiyoshi |
author_sort | Shinya, Akikazu |
collection | PubMed |
description | A three-dimensional (3D) finite element (FE) model of the mandibular bone was created from 3D X-ray CT scan images of a live human subject. Simulating the clinical situation of implant therapy at the mandibular first molar, virtual extraction of the tooth was performed at the 3D FE mandibular model, and 12 different implant diameters and lengths were virtually inserted in order to carry out a mechanical analysis. (1) High stress concentration was found at the surfaces of the buccal and lingual peri-implant bone adjacent to the sides of the neck in all the implants. (2) The greatest stress value was approximately 6.0 MPa with implant diameter of 3.8 mm, approx. 4.5 MPa with implant diameter of 4.3 mm, and approx. 3.2 MPa with implant diameter of 6.0 mm. (3) The stress on the peri-implant bone was found to decrease with increasing length and mainly in diameter of the implant. |
format | Online Article Text |
id | pubmed-8658520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86585202021-12-10 The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT Shinya, Akikazu Ishida, Yoshiki Miura, Daisuke Shinya, Akiyoshi Materials (Basel) Article A three-dimensional (3D) finite element (FE) model of the mandibular bone was created from 3D X-ray CT scan images of a live human subject. Simulating the clinical situation of implant therapy at the mandibular first molar, virtual extraction of the tooth was performed at the 3D FE mandibular model, and 12 different implant diameters and lengths were virtually inserted in order to carry out a mechanical analysis. (1) High stress concentration was found at the surfaces of the buccal and lingual peri-implant bone adjacent to the sides of the neck in all the implants. (2) The greatest stress value was approximately 6.0 MPa with implant diameter of 3.8 mm, approx. 4.5 MPa with implant diameter of 4.3 mm, and approx. 3.2 MPa with implant diameter of 6.0 mm. (3) The stress on the peri-implant bone was found to decrease with increasing length and mainly in diameter of the implant. MDPI 2021-11-30 /pmc/articles/PMC8658520/ /pubmed/34885508 http://dx.doi.org/10.3390/ma14237344 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shinya, Akikazu Ishida, Yoshiki Miura, Daisuke Shinya, Akiyoshi The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT |
title | The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT |
title_full | The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT |
title_fullStr | The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT |
title_full_unstemmed | The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT |
title_short | The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT |
title_sort | effect of implant length and diameter on stress distribution around single implant placement in 3d posterior mandibular fe model directly constructed form in vivo ct |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658520/ https://www.ncbi.nlm.nih.gov/pubmed/34885508 http://dx.doi.org/10.3390/ma14237344 |
work_keys_str_mv | AT shinyaakikazu theeffectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT ishidayoshiki theeffectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT miuradaisuke theeffectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT shinyaakiyoshi theeffectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT shinyaakikazu effectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT ishidayoshiki effectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT miuradaisuke effectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct AT shinyaakiyoshi effectofimplantlengthanddiameteronstressdistributionaroundsingleimplantplacementin3dposteriormandibularfemodeldirectlyconstructedforminvivoct |