Cargando…

Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome

Background: Cardiac troponin is the best marker to diagnose acute coronary syndrome (ACS). However, early diagnosis using markers for plaque instability may be of significance. Soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1) plays an important role in the pathogenesis of ath...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Sandeep, Ali, Wahid, Mishra, Sridhar, Pradhan, Akshyaya, Sethi, Rishi, Kushwaha, Rashmi, Singh, Uma Shankar, Perrone, Marco Alfonso
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658522/
https://www.ncbi.nlm.nih.gov/pubmed/34884269
http://dx.doi.org/10.3390/jcm10235567
_version_ 1784612752723017728
author Kumar, Sandeep
Ali, Wahid
Mishra, Sridhar
Pradhan, Akshyaya
Sethi, Rishi
Kushwaha, Rashmi
Singh, Uma Shankar
Perrone, Marco Alfonso
author_facet Kumar, Sandeep
Ali, Wahid
Mishra, Sridhar
Pradhan, Akshyaya
Sethi, Rishi
Kushwaha, Rashmi
Singh, Uma Shankar
Perrone, Marco Alfonso
author_sort Kumar, Sandeep
collection PubMed
description Background: Cardiac troponin is the best marker to diagnose acute coronary syndrome (ACS). However, early diagnosis using markers for plaque instability may be of significance. Soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1) plays an important role in the pathogenesis of atherosclerosis plaque rupture and may be a potential biomarker of coronary artery disease (CAD), including ACS. The current study aims to evaluate sLOX-1 levels in the sera of patients with ACS as an independent marker of CAD with other established diagnostic markers and assess its level before and after percutaneous intervention (PCI) in predicting the risk of future recurrence of ACS. Methods: Peripheral blood was obtained from a total of 160 patients, including patients who underwent coronary angiography (n = 18, group I), patients of stable CAD who underwent percutaneous intervention (n = 50, group II), patients of the acute coronary syndrome (n = 64, group III), and healthy controls (n = 28, group IV). A serum sLOX-1 concentration was measured by the enzyme-linked immunosorbent assay (ELISA). Results: The results obtained showed a statistically significant raised level of sLOX-1 in pre/post PCI patients of stable CAD/ACS with male preponderance. The area under the curve for sLOX-1 was 0.925 for cases that are discriminated from controls with sensitivity and specificity of 87.88 and 100%, respectively. SLOX-1 showed 100% sensitivity and specificity in the discrimination of the stable CAD that underwent PCI vs. control with an AUC of 1.00. The recurrence of coronary artery disease was observed in 9 out of 132 (6.8%) cases. The post-interventional sLOX-1 level was significantly different and higher in recurrent cases (p = 0.027) of ACS/CAD. Conclusions: sLOX-1 was a useful biomarker of stable CAD/ACS and has a potential in the risk prediction of a future recurrence of coronary artery disease.
format Online
Article
Text
id pubmed-8658522
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86585222021-12-10 Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome Kumar, Sandeep Ali, Wahid Mishra, Sridhar Pradhan, Akshyaya Sethi, Rishi Kushwaha, Rashmi Singh, Uma Shankar Perrone, Marco Alfonso J Clin Med Article Background: Cardiac troponin is the best marker to diagnose acute coronary syndrome (ACS). However, early diagnosis using markers for plaque instability may be of significance. Soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1) plays an important role in the pathogenesis of atherosclerosis plaque rupture and may be a potential biomarker of coronary artery disease (CAD), including ACS. The current study aims to evaluate sLOX-1 levels in the sera of patients with ACS as an independent marker of CAD with other established diagnostic markers and assess its level before and after percutaneous intervention (PCI) in predicting the risk of future recurrence of ACS. Methods: Peripheral blood was obtained from a total of 160 patients, including patients who underwent coronary angiography (n = 18, group I), patients of stable CAD who underwent percutaneous intervention (n = 50, group II), patients of the acute coronary syndrome (n = 64, group III), and healthy controls (n = 28, group IV). A serum sLOX-1 concentration was measured by the enzyme-linked immunosorbent assay (ELISA). Results: The results obtained showed a statistically significant raised level of sLOX-1 in pre/post PCI patients of stable CAD/ACS with male preponderance. The area under the curve for sLOX-1 was 0.925 for cases that are discriminated from controls with sensitivity and specificity of 87.88 and 100%, respectively. SLOX-1 showed 100% sensitivity and specificity in the discrimination of the stable CAD that underwent PCI vs. control with an AUC of 1.00. The recurrence of coronary artery disease was observed in 9 out of 132 (6.8%) cases. The post-interventional sLOX-1 level was significantly different and higher in recurrent cases (p = 0.027) of ACS/CAD. Conclusions: sLOX-1 was a useful biomarker of stable CAD/ACS and has a potential in the risk prediction of a future recurrence of coronary artery disease. MDPI 2021-11-26 /pmc/articles/PMC8658522/ /pubmed/34884269 http://dx.doi.org/10.3390/jcm10235567 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kumar, Sandeep
Ali, Wahid
Mishra, Sridhar
Pradhan, Akshyaya
Sethi, Rishi
Kushwaha, Rashmi
Singh, Uma Shankar
Perrone, Marco Alfonso
Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome
title Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome
title_full Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome
title_fullStr Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome
title_full_unstemmed Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome
title_short Circulating Soluble Lectin-like Oxidized Low-Density Lipoprotein Receptor-1 (sLOX-1): A Diagnostic Indicator across the Spectrum of Acute Coronary Syndrome
title_sort circulating soluble lectin-like oxidized low-density lipoprotein receptor-1 (slox-1): a diagnostic indicator across the spectrum of acute coronary syndrome
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8658522/
https://www.ncbi.nlm.nih.gov/pubmed/34884269
http://dx.doi.org/10.3390/jcm10235567
work_keys_str_mv AT kumarsandeep circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT aliwahid circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT mishrasridhar circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT pradhanakshyaya circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT sethirishi circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT kushwaharashmi circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT singhumashankar circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome
AT perronemarcoalfonso circulatingsolublelectinlikeoxidizedlowdensitylipoproteinreceptor1slox1adiagnosticindicatoracrossthespectrumofacutecoronarysyndrome