Cargando…

Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget

Periodic calibrations of Energy Measurement Systems (EMS) installed in locomotives must be carried out to demonstrate the required accuracy established in the EN 50463-2 standard according to European Parliament and Council Directive 2008/57/EC on the interoperability of rail systems within the Comm...

Descripción completa

Detalles Bibliográficos
Autores principales: Khamlichi, Abderrahim, Garnacho, Fernando, Simon, Pascual, Rovira, Jorge, Ramirez, Angel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8659960/
https://www.ncbi.nlm.nih.gov/pubmed/34883971
http://dx.doi.org/10.3390/s21237967
_version_ 1784613087852101632
author Khamlichi, Abderrahim
Garnacho, Fernando
Simon, Pascual
Rovira, Jorge
Ramirez, Angel
author_facet Khamlichi, Abderrahim
Garnacho, Fernando
Simon, Pascual
Rovira, Jorge
Ramirez, Angel
author_sort Khamlichi, Abderrahim
collection PubMed
description Periodic calibrations of Energy Measurement Systems (EMS) installed in locomotives must be carried out to demonstrate the required accuracy established in the EN 50463-2 standard according to European Parliament and Council Directive 2008/57/EC on the interoperability of rail systems within the Community. As a result of the work performed in the “MyRailS” EURAMET project an AC calibration facility was developed consisting of a fictive power source was developed. This fictive power source can generate distorted sinusoidal voltages up to 25 kV-50 Hz and 15 kV-16.7 Hz as well as distorted sinusoidal currents up to 500 A with harmonic content up to 5 kHz or phase-fired current waveform stated in EN50463-2 standard. These waveforms are representative of those that appear during periods of acceleration and breaking of the train. Reference measuring systems have been designed and built consisting of high voltage and high current transducers adapted to multimeters, which function as digital recorders to acquire synchronized voltage and current signals. An approved procedure has been developed and an in-depth uncertainty analysis has been performed to achieve a set of uncertainty formulas considering the influence parameters. Different influence parameters have been analyzed to evaluate uncertainty contributions for each quantity to be measured: rms voltage, rms current, active power, apparent power and non-active power of distorted voltage and current waveforms. The resulting calculated global expanded uncertainty for the developed Energy Measuring Function calibration set up has been better than 0.5% for distorted waveforms. This paper is focused on presenting the complete set of expressions and formulas developed for the different influence parameters, necessary for uncertainty budget calculation of an Energy Measuring Function calibration.
format Online
Article
Text
id pubmed-8659960
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86599602021-12-10 Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget Khamlichi, Abderrahim Garnacho, Fernando Simon, Pascual Rovira, Jorge Ramirez, Angel Sensors (Basel) Article Periodic calibrations of Energy Measurement Systems (EMS) installed in locomotives must be carried out to demonstrate the required accuracy established in the EN 50463-2 standard according to European Parliament and Council Directive 2008/57/EC on the interoperability of rail systems within the Community. As a result of the work performed in the “MyRailS” EURAMET project an AC calibration facility was developed consisting of a fictive power source was developed. This fictive power source can generate distorted sinusoidal voltages up to 25 kV-50 Hz and 15 kV-16.7 Hz as well as distorted sinusoidal currents up to 500 A with harmonic content up to 5 kHz or phase-fired current waveform stated in EN50463-2 standard. These waveforms are representative of those that appear during periods of acceleration and breaking of the train. Reference measuring systems have been designed and built consisting of high voltage and high current transducers adapted to multimeters, which function as digital recorders to acquire synchronized voltage and current signals. An approved procedure has been developed and an in-depth uncertainty analysis has been performed to achieve a set of uncertainty formulas considering the influence parameters. Different influence parameters have been analyzed to evaluate uncertainty contributions for each quantity to be measured: rms voltage, rms current, active power, apparent power and non-active power of distorted voltage and current waveforms. The resulting calculated global expanded uncertainty for the developed Energy Measuring Function calibration set up has been better than 0.5% for distorted waveforms. This paper is focused on presenting the complete set of expressions and formulas developed for the different influence parameters, necessary for uncertainty budget calculation of an Energy Measuring Function calibration. MDPI 2021-11-29 /pmc/articles/PMC8659960/ /pubmed/34883971 http://dx.doi.org/10.3390/s21237967 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Khamlichi, Abderrahim
Garnacho, Fernando
Simon, Pascual
Rovira, Jorge
Ramirez, Angel
Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget
title Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget
title_full Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget
title_fullStr Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget
title_full_unstemmed Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget
title_short Calibration of On-Board Energy Measurement Systems Installed in Locomotives for AC Distorted Current and High Voltage Waveforms and Determination of Its Uncertainty Budget
title_sort calibration of on-board energy measurement systems installed in locomotives for ac distorted current and high voltage waveforms and determination of its uncertainty budget
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8659960/
https://www.ncbi.nlm.nih.gov/pubmed/34883971
http://dx.doi.org/10.3390/s21237967
work_keys_str_mv AT khamlichiabderrahim calibrationofonboardenergymeasurementsystemsinstalledinlocomotivesforacdistortedcurrentandhighvoltagewaveformsanddeterminationofitsuncertaintybudget
AT garnachofernando calibrationofonboardenergymeasurementsystemsinstalledinlocomotivesforacdistortedcurrentandhighvoltagewaveformsanddeterminationofitsuncertaintybudget
AT simonpascual calibrationofonboardenergymeasurementsystemsinstalledinlocomotivesforacdistortedcurrentandhighvoltagewaveformsanddeterminationofitsuncertaintybudget
AT rovirajorge calibrationofonboardenergymeasurementsystemsinstalledinlocomotivesforacdistortedcurrentandhighvoltagewaveformsanddeterminationofitsuncertaintybudget
AT ramirezangel calibrationofonboardenergymeasurementsystemsinstalledinlocomotivesforacdistortedcurrentandhighvoltagewaveformsanddeterminationofitsuncertaintybudget