Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture

OBJECTIVE: To analyze the application value and relevance of risk evaluation system for arteriovenous fistula (AVF) puncture in thrombosis after puncture. METHODS: The clinical data of 180 patients treated with hemodialysis in the hemodialysis center of our hospital from November 2017 to November 20...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Mei, Sun, Chao, Du, Xuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8660209/
https://www.ncbi.nlm.nih.gov/pubmed/34900199
http://dx.doi.org/10.1155/2021/6919979
_version_ 1784613140812529664
author Li, Mei
Sun, Chao
Du, Xuan
author_facet Li, Mei
Sun, Chao
Du, Xuan
author_sort Li, Mei
collection PubMed
description OBJECTIVE: To analyze the application value and relevance of risk evaluation system for arteriovenous fistula (AVF) puncture in thrombosis after puncture. METHODS: The clinical data of 180 patients treated with hemodialysis in the hemodialysis center of our hospital from November 2017 to November 2019 were retrospectively analyzed. After puncture, all patients received the digital subtraction angiography (DSA) examination, and based on whether they had AVF thrombosis, they were divided into the nonthrombosis group (n = 102) and thrombosis group (n = 78), and then, according to the parity of their admission numbers, the patients in the thrombosis group were subdivided into the study group (n = 39) and the reference group (n = 39), so as to analyze the risk factors of thrombosis after AVF puncture and the application value of the risk evaluation system for AVF puncture in preventing and treating thrombosis. RESULTS: Compared with the reference group after intervention, the study group had significantly higher mean internal fistula blood flow volume (P < 0.001) and significantly lower total incidence rate of vascular complications in fistulas (P < 0.05); according to the multifactor binary logistic regression analysis, it was found that diabetes, systolic blood pressure reduction, hemoglobin, low-density lipoprotein cholesterol (LDL-C), ultrafiltration rate, and elevation of blood phosphorus and platelet levels were the risk factors of thrombosis after AVF puncture in hemodialysis patients. CONCLUSION: When risk factors of thrombosis are found in patients treated with hemodialysis, timely detection and intervention shall be applied in the early stage. Adopting the AVF puncture risk evaluation system has an extremely high application value in the clinic and is of important meaning in prolonging the service life of fistulas.
format Online
Article
Text
id pubmed-8660209
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-86602092021-12-10 Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture Li, Mei Sun, Chao Du, Xuan J Healthc Eng Research Article OBJECTIVE: To analyze the application value and relevance of risk evaluation system for arteriovenous fistula (AVF) puncture in thrombosis after puncture. METHODS: The clinical data of 180 patients treated with hemodialysis in the hemodialysis center of our hospital from November 2017 to November 2019 were retrospectively analyzed. After puncture, all patients received the digital subtraction angiography (DSA) examination, and based on whether they had AVF thrombosis, they were divided into the nonthrombosis group (n = 102) and thrombosis group (n = 78), and then, according to the parity of their admission numbers, the patients in the thrombosis group were subdivided into the study group (n = 39) and the reference group (n = 39), so as to analyze the risk factors of thrombosis after AVF puncture and the application value of the risk evaluation system for AVF puncture in preventing and treating thrombosis. RESULTS: Compared with the reference group after intervention, the study group had significantly higher mean internal fistula blood flow volume (P < 0.001) and significantly lower total incidence rate of vascular complications in fistulas (P < 0.05); according to the multifactor binary logistic regression analysis, it was found that diabetes, systolic blood pressure reduction, hemoglobin, low-density lipoprotein cholesterol (LDL-C), ultrafiltration rate, and elevation of blood phosphorus and platelet levels were the risk factors of thrombosis after AVF puncture in hemodialysis patients. CONCLUSION: When risk factors of thrombosis are found in patients treated with hemodialysis, timely detection and intervention shall be applied in the early stage. Adopting the AVF puncture risk evaluation system has an extremely high application value in the clinic and is of important meaning in prolonging the service life of fistulas. Hindawi 2021-12-02 /pmc/articles/PMC8660209/ /pubmed/34900199 http://dx.doi.org/10.1155/2021/6919979 Text en Copyright © 2021 Mei Li et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Li, Mei
Sun, Chao
Du, Xuan
Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
title Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
title_full Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
title_fullStr Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
title_full_unstemmed Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
title_short Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
title_sort application value and relevance analysis of the risk evaluation system for arteriovenous fistula puncture in thrombosis after puncture
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8660209/
https://www.ncbi.nlm.nih.gov/pubmed/34900199
http://dx.doi.org/10.1155/2021/6919979
work_keys_str_mv AT limei applicationvalueandrelevanceanalysisoftheriskevaluationsystemforarteriovenousfistulapunctureinthrombosisafterpuncture
AT sunchao applicationvalueandrelevanceanalysisoftheriskevaluationsystemforarteriovenousfistulapunctureinthrombosisafterpuncture
AT duxuan applicationvalueandrelevanceanalysisoftheriskevaluationsystemforarteriovenousfistulapunctureinthrombosisafterpuncture