Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture
OBJECTIVE: To analyze the application value and relevance of risk evaluation system for arteriovenous fistula (AVF) puncture in thrombosis after puncture. METHODS: The clinical data of 180 patients treated with hemodialysis in the hemodialysis center of our hospital from November 2017 to November 20...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8660209/ https://www.ncbi.nlm.nih.gov/pubmed/34900199 http://dx.doi.org/10.1155/2021/6919979 |
_version_ | 1784613140812529664 |
---|---|
author | Li, Mei Sun, Chao Du, Xuan |
author_facet | Li, Mei Sun, Chao Du, Xuan |
author_sort | Li, Mei |
collection | PubMed |
description | OBJECTIVE: To analyze the application value and relevance of risk evaluation system for arteriovenous fistula (AVF) puncture in thrombosis after puncture. METHODS: The clinical data of 180 patients treated with hemodialysis in the hemodialysis center of our hospital from November 2017 to November 2019 were retrospectively analyzed. After puncture, all patients received the digital subtraction angiography (DSA) examination, and based on whether they had AVF thrombosis, they were divided into the nonthrombosis group (n = 102) and thrombosis group (n = 78), and then, according to the parity of their admission numbers, the patients in the thrombosis group were subdivided into the study group (n = 39) and the reference group (n = 39), so as to analyze the risk factors of thrombosis after AVF puncture and the application value of the risk evaluation system for AVF puncture in preventing and treating thrombosis. RESULTS: Compared with the reference group after intervention, the study group had significantly higher mean internal fistula blood flow volume (P < 0.001) and significantly lower total incidence rate of vascular complications in fistulas (P < 0.05); according to the multifactor binary logistic regression analysis, it was found that diabetes, systolic blood pressure reduction, hemoglobin, low-density lipoprotein cholesterol (LDL-C), ultrafiltration rate, and elevation of blood phosphorus and platelet levels were the risk factors of thrombosis after AVF puncture in hemodialysis patients. CONCLUSION: When risk factors of thrombosis are found in patients treated with hemodialysis, timely detection and intervention shall be applied in the early stage. Adopting the AVF puncture risk evaluation system has an extremely high application value in the clinic and is of important meaning in prolonging the service life of fistulas. |
format | Online Article Text |
id | pubmed-8660209 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-86602092021-12-10 Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture Li, Mei Sun, Chao Du, Xuan J Healthc Eng Research Article OBJECTIVE: To analyze the application value and relevance of risk evaluation system for arteriovenous fistula (AVF) puncture in thrombosis after puncture. METHODS: The clinical data of 180 patients treated with hemodialysis in the hemodialysis center of our hospital from November 2017 to November 2019 were retrospectively analyzed. After puncture, all patients received the digital subtraction angiography (DSA) examination, and based on whether they had AVF thrombosis, they were divided into the nonthrombosis group (n = 102) and thrombosis group (n = 78), and then, according to the parity of their admission numbers, the patients in the thrombosis group were subdivided into the study group (n = 39) and the reference group (n = 39), so as to analyze the risk factors of thrombosis after AVF puncture and the application value of the risk evaluation system for AVF puncture in preventing and treating thrombosis. RESULTS: Compared with the reference group after intervention, the study group had significantly higher mean internal fistula blood flow volume (P < 0.001) and significantly lower total incidence rate of vascular complications in fistulas (P < 0.05); according to the multifactor binary logistic regression analysis, it was found that diabetes, systolic blood pressure reduction, hemoglobin, low-density lipoprotein cholesterol (LDL-C), ultrafiltration rate, and elevation of blood phosphorus and platelet levels were the risk factors of thrombosis after AVF puncture in hemodialysis patients. CONCLUSION: When risk factors of thrombosis are found in patients treated with hemodialysis, timely detection and intervention shall be applied in the early stage. Adopting the AVF puncture risk evaluation system has an extremely high application value in the clinic and is of important meaning in prolonging the service life of fistulas. Hindawi 2021-12-02 /pmc/articles/PMC8660209/ /pubmed/34900199 http://dx.doi.org/10.1155/2021/6919979 Text en Copyright © 2021 Mei Li et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Li, Mei Sun, Chao Du, Xuan Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture |
title | Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture |
title_full | Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture |
title_fullStr | Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture |
title_full_unstemmed | Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture |
title_short | Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture |
title_sort | application value and relevance analysis of the risk evaluation system for arteriovenous fistula puncture in thrombosis after puncture |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8660209/ https://www.ncbi.nlm.nih.gov/pubmed/34900199 http://dx.doi.org/10.1155/2021/6919979 |
work_keys_str_mv | AT limei applicationvalueandrelevanceanalysisoftheriskevaluationsystemforarteriovenousfistulapunctureinthrombosisafterpuncture AT sunchao applicationvalueandrelevanceanalysisoftheriskevaluationsystemforarteriovenousfistulapunctureinthrombosisafterpuncture AT duxuan applicationvalueandrelevanceanalysisoftheriskevaluationsystemforarteriovenousfistulapunctureinthrombosisafterpuncture |