Cargando…

A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance

PURPOSE: This study evaluates the performance of a mobile and compact hybrid C-arm scanner (referred to as IXSI) that is capable of simultaneous acquisition of 2D fluoroscopic and nuclear projections and 3D image reconstruction in the intervention room. RESULTS: The impact of slightly misaligning th...

Descripción completa

Detalles Bibliográficos
Autores principales: Dietze, Martijn M. A., Kunnen, Britt, Brontsema, Frank, Ramaekers, Pascal, Beijst, Casper, Afifah, Maryam, Braat, Arthur J. A. T., Lam, Marnix G. E. H., de Jong, Hugo W. A. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8660732/
https://www.ncbi.nlm.nih.gov/pubmed/34132877
http://dx.doi.org/10.1007/s00330-021-08023-4
_version_ 1784613250205220864
author Dietze, Martijn M. A.
Kunnen, Britt
Brontsema, Frank
Ramaekers, Pascal
Beijst, Casper
Afifah, Maryam
Braat, Arthur J. A. T.
Lam, Marnix G. E. H.
de Jong, Hugo W. A. M.
author_facet Dietze, Martijn M. A.
Kunnen, Britt
Brontsema, Frank
Ramaekers, Pascal
Beijst, Casper
Afifah, Maryam
Braat, Arthur J. A. T.
Lam, Marnix G. E. H.
de Jong, Hugo W. A. M.
author_sort Dietze, Martijn M. A.
collection PubMed
description PURPOSE: This study evaluates the performance of a mobile and compact hybrid C-arm scanner (referred to as IXSI) that is capable of simultaneous acquisition of 2D fluoroscopic and nuclear projections and 3D image reconstruction in the intervention room. RESULTS: The impact of slightly misaligning the IXSI modalities (in an off-focus geometry) was investigated for the reduction of the fluoroscopic and nuclear interference. The 2D and 3D nuclear image quality of IXSI was compared with a clinical SPECT/CT scanner by determining the spatial resolution and sensitivity of point sources and by performing a quantitative analysis of the reconstructed NEMA image quality phantom. The 2D and 3D fluoroscopic image of IXSI was compared with a clinical CBCT scanner by visualizing the Fluorad A+D image quality phantom and by visualizing a reconstructed liver nodule phantom. Finally, the feasibility of dynamic simultaneous nuclear and fluoroscopic imaging was demonstrated by injecting an anthropomorphic phantom with a mixture of iodinated contrast and (99m)Tc. CONCLUSION: Due to the divergent innovative hybrid design of IXSI, concessions were made to the nuclear and fluoroscopic image qualities. Nevertheless, IXSI realizes unique image guidance that may be beneficial for several types of procedures. KEY POINTS: • IXSI can perform time-resolved planar (2D) simultaneous fluoroscopic and nuclear imaging. • IXSI can perform SPECT/CBCT imaging (3D) inside the intervention room. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-021-08023-4.
format Online
Article
Text
id pubmed-8660732
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-86607322021-12-27 A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance Dietze, Martijn M. A. Kunnen, Britt Brontsema, Frank Ramaekers, Pascal Beijst, Casper Afifah, Maryam Braat, Arthur J. A. T. Lam, Marnix G. E. H. de Jong, Hugo W. A. M. Eur Radiol Physics PURPOSE: This study evaluates the performance of a mobile and compact hybrid C-arm scanner (referred to as IXSI) that is capable of simultaneous acquisition of 2D fluoroscopic and nuclear projections and 3D image reconstruction in the intervention room. RESULTS: The impact of slightly misaligning the IXSI modalities (in an off-focus geometry) was investigated for the reduction of the fluoroscopic and nuclear interference. The 2D and 3D nuclear image quality of IXSI was compared with a clinical SPECT/CT scanner by determining the spatial resolution and sensitivity of point sources and by performing a quantitative analysis of the reconstructed NEMA image quality phantom. The 2D and 3D fluoroscopic image of IXSI was compared with a clinical CBCT scanner by visualizing the Fluorad A+D image quality phantom and by visualizing a reconstructed liver nodule phantom. Finally, the feasibility of dynamic simultaneous nuclear and fluoroscopic imaging was demonstrated by injecting an anthropomorphic phantom with a mixture of iodinated contrast and (99m)Tc. CONCLUSION: Due to the divergent innovative hybrid design of IXSI, concessions were made to the nuclear and fluoroscopic image qualities. Nevertheless, IXSI realizes unique image guidance that may be beneficial for several types of procedures. KEY POINTS: • IXSI can perform time-resolved planar (2D) simultaneous fluoroscopic and nuclear imaging. • IXSI can perform SPECT/CBCT imaging (3D) inside the intervention room. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-021-08023-4. Springer Berlin Heidelberg 2021-06-16 2022 /pmc/articles/PMC8660732/ /pubmed/34132877 http://dx.doi.org/10.1007/s00330-021-08023-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Physics
Dietze, Martijn M. A.
Kunnen, Britt
Brontsema, Frank
Ramaekers, Pascal
Beijst, Casper
Afifah, Maryam
Braat, Arthur J. A. T.
Lam, Marnix G. E. H.
de Jong, Hugo W. A. M.
A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance
title A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance
title_full A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance
title_fullStr A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance
title_full_unstemmed A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance
title_short A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance
title_sort compact and mobile hybrid c-arm scanner for simultaneous nuclear and fluoroscopic image guidance
topic Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8660732/
https://www.ncbi.nlm.nih.gov/pubmed/34132877
http://dx.doi.org/10.1007/s00330-021-08023-4
work_keys_str_mv AT dietzemartijnma acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT kunnenbritt acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT brontsemafrank acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT ramaekerspascal acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT beijstcasper acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT afifahmaryam acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT braatarthurjat acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT lammarnixgeh acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT dejonghugowam acompactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT dietzemartijnma compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT kunnenbritt compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT brontsemafrank compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT ramaekerspascal compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT beijstcasper compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT afifahmaryam compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT braatarthurjat compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT lammarnixgeh compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance
AT dejonghugowam compactandmobilehybridcarmscannerforsimultaneousnuclearandfluoroscopicimageguidance