Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials
Background: Randomized controlled trials (RCTs) evaluating the influence of personal protective equipment (PPE) on quality of chest compressions during cardiopulmonary resuscitation (CPR) showed inconsistent results. Accordingly, a meta-analysis was performed to provide an overview. Methods: Relevan...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8662528/ https://www.ncbi.nlm.nih.gov/pubmed/34901055 http://dx.doi.org/10.3389/fmed.2021.733724 |
_version_ | 1784613457970069504 |
---|---|
author | Cui, Ying Jiang, Siyi |
author_facet | Cui, Ying Jiang, Siyi |
author_sort | Cui, Ying |
collection | PubMed |
description | Background: Randomized controlled trials (RCTs) evaluating the influence of personal protective equipment (PPE) on quality of chest compressions during cardiopulmonary resuscitation (CPR) showed inconsistent results. Accordingly, a meta-analysis was performed to provide an overview. Methods: Relevant studies were obtained by search of Medline, Embase, and Cochrane's Library databases. A random-effect model incorporating the potential heterogeneity was used to pool the results. Results: Six simulation-based RCTs were included. Overall, pooled results showed that there was no statistically significant difference between the rate [mean difference (MD): −1.70 time/min, 95% confidence interval (CI): −5.77 to 2.36, P = 0.41, I(2) = 80%] or the depth [MD: −1.84 mm, 95% CI: −3.93 to 0.24, P = 0.11, I(2) = 73%] of chest compressions performed by medical personnel with and without PPE. Subgroup analyses showed that use of PPE was associated with reduced rate of chest compressions in studies before COVID-19 (MD: −7.02 time/min, 95% CI: −10.46 to −3.57, P < 0.001), but not in studies after COVID-19 (MD: 0.14 time/min, 95% CI: −5.77 to 2.36, P = 0.95). In addition, PPE was not associated with significantly reduced depth of chest compressions in studies before (MD: −3.34 mm, 95% CI: −10.29 to −3.62, P = 0.35) or after (MD: −0.97 mm, 95% CI: −2.62 to 0.68, P = 0.25) COVID-19. No significant difference was found between parallel-group and crossover RCTs (P for subgroup difference both > 0.05). Conclusions: Evidence from simulation-based RCTs showed that use of PPE was not associated with reduced rate or depth of chest compressions in CPR. |
format | Online Article Text |
id | pubmed-8662528 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86625282021-12-11 Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials Cui, Ying Jiang, Siyi Front Med (Lausanne) Medicine Background: Randomized controlled trials (RCTs) evaluating the influence of personal protective equipment (PPE) on quality of chest compressions during cardiopulmonary resuscitation (CPR) showed inconsistent results. Accordingly, a meta-analysis was performed to provide an overview. Methods: Relevant studies were obtained by search of Medline, Embase, and Cochrane's Library databases. A random-effect model incorporating the potential heterogeneity was used to pool the results. Results: Six simulation-based RCTs were included. Overall, pooled results showed that there was no statistically significant difference between the rate [mean difference (MD): −1.70 time/min, 95% confidence interval (CI): −5.77 to 2.36, P = 0.41, I(2) = 80%] or the depth [MD: −1.84 mm, 95% CI: −3.93 to 0.24, P = 0.11, I(2) = 73%] of chest compressions performed by medical personnel with and without PPE. Subgroup analyses showed that use of PPE was associated with reduced rate of chest compressions in studies before COVID-19 (MD: −7.02 time/min, 95% CI: −10.46 to −3.57, P < 0.001), but not in studies after COVID-19 (MD: 0.14 time/min, 95% CI: −5.77 to 2.36, P = 0.95). In addition, PPE was not associated with significantly reduced depth of chest compressions in studies before (MD: −3.34 mm, 95% CI: −10.29 to −3.62, P = 0.35) or after (MD: −0.97 mm, 95% CI: −2.62 to 0.68, P = 0.25) COVID-19. No significant difference was found between parallel-group and crossover RCTs (P for subgroup difference both > 0.05). Conclusions: Evidence from simulation-based RCTs showed that use of PPE was not associated with reduced rate or depth of chest compressions in CPR. Frontiers Media S.A. 2021-11-26 /pmc/articles/PMC8662528/ /pubmed/34901055 http://dx.doi.org/10.3389/fmed.2021.733724 Text en Copyright © 2021 Cui and Jiang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Cui, Ying Jiang, Siyi Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials |
title | Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials |
title_full | Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials |
title_fullStr | Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials |
title_full_unstemmed | Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials |
title_short | Influence of Personal Protective Equipment on the Quality of Chest Compressions: A Meta-Analysis of Randomized Controlled Trials |
title_sort | influence of personal protective equipment on the quality of chest compressions: a meta-analysis of randomized controlled trials |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8662528/ https://www.ncbi.nlm.nih.gov/pubmed/34901055 http://dx.doi.org/10.3389/fmed.2021.733724 |
work_keys_str_mv | AT cuiying influenceofpersonalprotectiveequipmentonthequalityofchestcompressionsametaanalysisofrandomizedcontrolledtrials AT jiangsiyi influenceofpersonalprotectiveequipmentonthequalityofchestcompressionsametaanalysisofrandomizedcontrolledtrials |