BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused a global pandemic beginning in 2020, can be detected by reverse-transcription polymerase chain reaction (RT-PCR). However, owing to the urgent need for a large number of detection kits, the time spent research...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Mei, Cao, Shuang, Liu, Yong, Zhang, Zhijie, Zheng, Rui, Li, Yuzhong, Zhou, Jie, Zong, Chengguo, Cao, Desheng, Qin, Xiaosong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Published by Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8662914/
https://www.ncbi.nlm.nih.gov/pubmed/34902345
http://dx.doi.org/10.1016/j.cca.2021.12.004
_version_ 1784613536365805568
author Yang, Mei
Cao, Shuang
Liu, Yong
Zhang, Zhijie
Zheng, Rui
Li, Yuzhong
Zhou, Jie
Zong, Chengguo
Cao, Desheng
Qin, Xiaosong
author_facet Yang, Mei
Cao, Shuang
Liu, Yong
Zhang, Zhijie
Zheng, Rui
Li, Yuzhong
Zhou, Jie
Zong, Chengguo
Cao, Desheng
Qin, Xiaosong
author_sort Yang, Mei
collection PubMed
description BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused a global pandemic beginning in 2020, can be detected by reverse-transcription polymerase chain reaction (RT-PCR). However, owing to the urgent need for a large number of detection kits, the time spent researching and developing these kits has been shortened during the pandemic, and the kits that are being used commercially have not undergone full and independent evaluation. To ensure the accuracy of SARS-CoV-2 test results, performance verification of commercial Real-Time quantitative PCR (RT-qPCR) kits is required. METHODS: The performance of five commercial RT-qPCR diagnostic kits for SARS-CoV-2 used in China was evaluated using a coronavirus disease 2019 (COVID-19) RNA liquid performance verification reference product-manufactured by Guangzhou Bondson (BDS) Biotechnology Co., Ltd.,Guangzhou, China-that uses droplet digital RT-PCR technology combined with fluorescence quantitative PCR. The five kits of Novel Coronavirus 2019-nCoV nucleic acid detection kit (RT-qPCR method) evaluated were Da An (Da An Gene Co., Ltd. of Sun Yat-sen University), Liferiver (Shanghai ZJ Bio-Tech Co., Ltd.), Kinghawk (Beijing Kinghawk Pharmaceutical Co., Ltd.), eDiagnosis (Wuhan Easy Diagnosis Biomedicine Co., Ltd.), and Maccura (Maccura Biotechnology Co., Ltd.). Performance verification criteria included the coincidence rate, limit of detection (LoD), cross-reactivity, precision, and anti-interference. Finally, through the BDS performance verification reference product kit, clinical samples are used to verify its clinical diagnostic efficacy. RESULTS: The coincidence rate was 100% for all kits except for Kinghawk, which was 95%. The LoD for Da An, eDiagnosis and Maccura was 250copies/mL, and it was 1000 copies/ml for Liferiver. Kinghawk was not able to detect its advertised LoD of 500 copies/ml. The cross-reactivity test results were all negative. Moreover, all kits had a coefficient of variation less than 5%; however, Liferiver showed the best precision. Da An, Liferiver, and eDiagnosis showed higher sensitivity to the nucleocapsid (N) gene than they did to the open reading frame (ORF) 1ab genes. Anti-interference results for all five kits were positive. The results of clinical diagnostic efficacy were that the specificity of the four kits was 1.000 (0.877–1.000), the sensitivity of Da An was 1.000 (0.850–1.000), Liferiver was 0.964 (0.798–0.998), Maccura was 0.893 (0.706–0.972), and eDiagnosis was 0.857 (0.664–0.953). CONCLUSIONS: All commercial RT-qPCR diagnostic kits for SARS-CoV-2 passed the BDS performance verification, except for Kinghawk (batch No:20200608113) which failed to detect the LoD of 500 copies/mL. Da An and Liferiver have excellent clinical diagnostic specificity and sensitivity. This study can provide guidance for the selection or optimization of RT-qPCR diagnostic test kits for SARS-CoV-2.
format Online
Article
Text
id pubmed-8662914
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Published by Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-86629142021-12-10 Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2 Yang, Mei Cao, Shuang Liu, Yong Zhang, Zhijie Zheng, Rui Li, Yuzhong Zhou, Jie Zong, Chengguo Cao, Desheng Qin, Xiaosong Clin Chim Acta Article BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused a global pandemic beginning in 2020, can be detected by reverse-transcription polymerase chain reaction (RT-PCR). However, owing to the urgent need for a large number of detection kits, the time spent researching and developing these kits has been shortened during the pandemic, and the kits that are being used commercially have not undergone full and independent evaluation. To ensure the accuracy of SARS-CoV-2 test results, performance verification of commercial Real-Time quantitative PCR (RT-qPCR) kits is required. METHODS: The performance of five commercial RT-qPCR diagnostic kits for SARS-CoV-2 used in China was evaluated using a coronavirus disease 2019 (COVID-19) RNA liquid performance verification reference product-manufactured by Guangzhou Bondson (BDS) Biotechnology Co., Ltd.,Guangzhou, China-that uses droplet digital RT-PCR technology combined with fluorescence quantitative PCR. The five kits of Novel Coronavirus 2019-nCoV nucleic acid detection kit (RT-qPCR method) evaluated were Da An (Da An Gene Co., Ltd. of Sun Yat-sen University), Liferiver (Shanghai ZJ Bio-Tech Co., Ltd.), Kinghawk (Beijing Kinghawk Pharmaceutical Co., Ltd.), eDiagnosis (Wuhan Easy Diagnosis Biomedicine Co., Ltd.), and Maccura (Maccura Biotechnology Co., Ltd.). Performance verification criteria included the coincidence rate, limit of detection (LoD), cross-reactivity, precision, and anti-interference. Finally, through the BDS performance verification reference product kit, clinical samples are used to verify its clinical diagnostic efficacy. RESULTS: The coincidence rate was 100% for all kits except for Kinghawk, which was 95%. The LoD for Da An, eDiagnosis and Maccura was 250copies/mL, and it was 1000 copies/ml for Liferiver. Kinghawk was not able to detect its advertised LoD of 500 copies/ml. The cross-reactivity test results were all negative. Moreover, all kits had a coefficient of variation less than 5%; however, Liferiver showed the best precision. Da An, Liferiver, and eDiagnosis showed higher sensitivity to the nucleocapsid (N) gene than they did to the open reading frame (ORF) 1ab genes. Anti-interference results for all five kits were positive. The results of clinical diagnostic efficacy were that the specificity of the four kits was 1.000 (0.877–1.000), the sensitivity of Da An was 1.000 (0.850–1.000), Liferiver was 0.964 (0.798–0.998), Maccura was 0.893 (0.706–0.972), and eDiagnosis was 0.857 (0.664–0.953). CONCLUSIONS: All commercial RT-qPCR diagnostic kits for SARS-CoV-2 passed the BDS performance verification, except for Kinghawk (batch No:20200608113) which failed to detect the LoD of 500 copies/mL. Da An and Liferiver have excellent clinical diagnostic specificity and sensitivity. This study can provide guidance for the selection or optimization of RT-qPCR diagnostic test kits for SARS-CoV-2. Published by Elsevier B.V. 2022-01-15 2021-12-10 /pmc/articles/PMC8662914/ /pubmed/34902345 http://dx.doi.org/10.1016/j.cca.2021.12.004 Text en © 2021 Published by Elsevier B.V. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Yang, Mei
Cao, Shuang
Liu, Yong
Zhang, Zhijie
Zheng, Rui
Li, Yuzhong
Zhou, Jie
Zong, Chengguo
Cao, Desheng
Qin, Xiaosong
Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2
title Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2
title_full Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2
title_fullStr Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2
title_full_unstemmed Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2
title_short Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2
title_sort performance verification of five commercial rt-qpcr diagnostic kits for sars-cov-2
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8662914/
https://www.ncbi.nlm.nih.gov/pubmed/34902345
http://dx.doi.org/10.1016/j.cca.2021.12.004
work_keys_str_mv AT yangmei performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT caoshuang performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT liuyong performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT zhangzhijie performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT zhengrui performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT liyuzhong performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT zhoujie performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT zongchengguo performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT caodesheng performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2
AT qinxiaosong performanceverificationoffivecommercialrtqpcrdiagnostickitsforsarscov2