Cargando…
Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair
Stent graft collapse due to aortic dissection is an extremely rare event. Although endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR) are increasingly being performed, various complications can occur. We report a case of collapse of a stent graft, which was used to r...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8663086/ https://www.ncbi.nlm.nih.gov/pubmed/34887297 http://dx.doi.org/10.1136/bcr-2021-246798 |
_version_ | 1784613561762316288 |
---|---|
author | Takagi, Sho Goto, Yoshihiro Yanagisawa, Junji Nakasu, Akio |
author_facet | Takagi, Sho Goto, Yoshihiro Yanagisawa, Junji Nakasu, Akio |
author_sort | Takagi, Sho |
collection | PubMed |
description | Stent graft collapse due to aortic dissection is an extremely rare event. Although endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR) are increasingly being performed, various complications can occur. We report a case of collapse of a stent graft, which was used to repair an abdominal aortic aneurysm (AAA) after TEVAR for thoracic aortic aneurysm (TAA). A 72-year-old man with a 77 mm AAA and 60 mm TAA underwent EVAR and a TEVAR 2 months later, respectively. CT performed after the TEVAR showed thoracic aorta dissection with associated AAA stent graft collapse. The graft collapsed was due to superior mesenteric artery obstruction. An emergency TEVAR was performed, and the procedure improved the collapsed graft; however, the endoleak of the AAA stent graft persisted. The AAA expanded over several days, warranting an open repair. Our case provides an insight into the cautionary indications for endovascular therapy. |
format | Online Article Text |
id | pubmed-8663086 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-86630862021-12-27 Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair Takagi, Sho Goto, Yoshihiro Yanagisawa, Junji Nakasu, Akio BMJ Case Rep Case Report Stent graft collapse due to aortic dissection is an extremely rare event. Although endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR) are increasingly being performed, various complications can occur. We report a case of collapse of a stent graft, which was used to repair an abdominal aortic aneurysm (AAA) after TEVAR for thoracic aortic aneurysm (TAA). A 72-year-old man with a 77 mm AAA and 60 mm TAA underwent EVAR and a TEVAR 2 months later, respectively. CT performed after the TEVAR showed thoracic aorta dissection with associated AAA stent graft collapse. The graft collapsed was due to superior mesenteric artery obstruction. An emergency TEVAR was performed, and the procedure improved the collapsed graft; however, the endoleak of the AAA stent graft persisted. The AAA expanded over several days, warranting an open repair. Our case provides an insight into the cautionary indications for endovascular therapy. BMJ Publishing Group 2021-12-09 /pmc/articles/PMC8663086/ /pubmed/34887297 http://dx.doi.org/10.1136/bcr-2021-246798 Text en © BMJ Publishing Group Limited 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Case Report Takagi, Sho Goto, Yoshihiro Yanagisawa, Junji Nakasu, Akio Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
title | Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
title_full | Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
title_fullStr | Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
title_full_unstemmed | Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
title_short | Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
title_sort | stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8663086/ https://www.ncbi.nlm.nih.gov/pubmed/34887297 http://dx.doi.org/10.1136/bcr-2021-246798 |
work_keys_str_mv | AT takagisho stentgraftinabdominalaorticaneurysmcollapsedsuddenlyafterthoracicendovascularaorticrepair AT gotoyoshihiro stentgraftinabdominalaorticaneurysmcollapsedsuddenlyafterthoracicendovascularaorticrepair AT yanagisawajunji stentgraftinabdominalaorticaneurysmcollapsedsuddenlyafterthoracicendovascularaorticrepair AT nakasuakio stentgraftinabdominalaorticaneurysmcollapsedsuddenlyafterthoracicendovascularaorticrepair |