Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector
The objective of the present study was to develop a method to measure tedizolid (TZD) concentration for studying target concentration intervention, pharmacokinetics, and pharmacodynamics of TZD. We established a high-performance liquid chromatography-fluorescence detector assay to measure the TZD co...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8663851/ https://www.ncbi.nlm.nih.gov/pubmed/34889275 http://dx.doi.org/10.1097/MD.0000000000028127 |
_version_ | 1784613733538988032 |
---|---|
author | Tsuji, Yasuhiro Numajiri, Miki Ogami, Chika Kurosaki, Fumihiro Miyamoto, Aoi Aoyama, Takahiko Kawasuji, Hitoshi Nagaoka, Kentaro Matsumoto, Yoshiaki To, Hideto Yamamoto, Yoshihiro |
author_facet | Tsuji, Yasuhiro Numajiri, Miki Ogami, Chika Kurosaki, Fumihiro Miyamoto, Aoi Aoyama, Takahiko Kawasuji, Hitoshi Nagaoka, Kentaro Matsumoto, Yoshiaki To, Hideto Yamamoto, Yoshihiro |
author_sort | Tsuji, Yasuhiro |
collection | PubMed |
description | The objective of the present study was to develop a method to measure tedizolid (TZD) concentration for studying target concentration intervention, pharmacokinetics, and pharmacodynamics of TZD. We established a high-performance liquid chromatography-fluorescence detector assay to measure the TZD concentration in serum for clinical application. Chromatographic separation was carried out on a 5 μm octadecyl silane hypersil column 150 mm × 4.6 mm. The mobile phase consisted of 0.1 M phosphoric acid and methanol (60:40, pH 7.0). Detection was performed at 300 nm and 340 nm for the excitation and emission wavelengths, respectively. The average retention times of TZD and the internal standard were 12.9 and 8.8 min, respectively. High linearity was exhibited over a concentration range of 0.025 to 10.0 μg/mL for TZD (R(2) > 0.999). The intra- and inter-assay accuracies of TZD were 99.2% to 107.0% and 99.2% to 107.7%, respectively. The lower limit of quantitation and the lower limit of detection for TZD measurement were 0.025 and 0.01 μg/mL, respectively. The extraction recoveries of TZD were 100.4% to 114.1%. The high-performance liquid chromatography method developed in this study could separate the analytes with a single eluent (isocratic system), within a total run time of 15 min. Both TZD and IS were well separated, without interference from the peaks. Sharp peaks were observed in the chromatograms; problems such as double peaks, shoulder peaks, and broadened peaks were not observed. The proposed method showed acceptable analytical performance and could be used to evaluate serum TZD concentrations in patients. |
format | Online Article Text |
id | pubmed-8663851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-86638512021-12-13 Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector Tsuji, Yasuhiro Numajiri, Miki Ogami, Chika Kurosaki, Fumihiro Miyamoto, Aoi Aoyama, Takahiko Kawasuji, Hitoshi Nagaoka, Kentaro Matsumoto, Yoshiaki To, Hideto Yamamoto, Yoshihiro Medicine (Baltimore) 4900 The objective of the present study was to develop a method to measure tedizolid (TZD) concentration for studying target concentration intervention, pharmacokinetics, and pharmacodynamics of TZD. We established a high-performance liquid chromatography-fluorescence detector assay to measure the TZD concentration in serum for clinical application. Chromatographic separation was carried out on a 5 μm octadecyl silane hypersil column 150 mm × 4.6 mm. The mobile phase consisted of 0.1 M phosphoric acid and methanol (60:40, pH 7.0). Detection was performed at 300 nm and 340 nm for the excitation and emission wavelengths, respectively. The average retention times of TZD and the internal standard were 12.9 and 8.8 min, respectively. High linearity was exhibited over a concentration range of 0.025 to 10.0 μg/mL for TZD (R(2) > 0.999). The intra- and inter-assay accuracies of TZD were 99.2% to 107.0% and 99.2% to 107.7%, respectively. The lower limit of quantitation and the lower limit of detection for TZD measurement were 0.025 and 0.01 μg/mL, respectively. The extraction recoveries of TZD were 100.4% to 114.1%. The high-performance liquid chromatography method developed in this study could separate the analytes with a single eluent (isocratic system), within a total run time of 15 min. Both TZD and IS were well separated, without interference from the peaks. Sharp peaks were observed in the chromatograms; problems such as double peaks, shoulder peaks, and broadened peaks were not observed. The proposed method showed acceptable analytical performance and could be used to evaluate serum TZD concentrations in patients. Lippincott Williams & Wilkins 2021-12-10 /pmc/articles/PMC8663851/ /pubmed/34889275 http://dx.doi.org/10.1097/MD.0000000000028127 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) |
spellingShingle | 4900 Tsuji, Yasuhiro Numajiri, Miki Ogami, Chika Kurosaki, Fumihiro Miyamoto, Aoi Aoyama, Takahiko Kawasuji, Hitoshi Nagaoka, Kentaro Matsumoto, Yoshiaki To, Hideto Yamamoto, Yoshihiro Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector |
title | Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector |
title_full | Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector |
title_fullStr | Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector |
title_full_unstemmed | Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector |
title_short | Development of a simple method for measuring tedizolid concentration in human serum using HPLC with a fluorescent detector |
title_sort | development of a simple method for measuring tedizolid concentration in human serum using hplc with a fluorescent detector |
topic | 4900 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8663851/ https://www.ncbi.nlm.nih.gov/pubmed/34889275 http://dx.doi.org/10.1097/MD.0000000000028127 |
work_keys_str_mv | AT tsujiyasuhiro developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT numajirimiki developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT ogamichika developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT kurosakifumihiro developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT miyamotoaoi developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT aoyamatakahiko developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT kawasujihitoshi developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT nagaokakentaro developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT matsumotoyoshiaki developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT tohideto developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector AT yamamotoyoshihiro developmentofasimplemethodformeasuringtedizolidconcentrationinhumanserumusinghplcwithafluorescentdetector |