Interinstitutional beam model portability study in a mixed vendor environment
A 6 MV flattened beam model for a Varian TrueBeamSTx c‐arm treatment delivery system in RayStation, developed and validated at one institution, was implemented and validated at another institution. The only parameter value adjustments were to accommodate machine output at the second institution. Val...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8664150/ https://www.ncbi.nlm.nih.gov/pubmed/34643323 http://dx.doi.org/10.1002/acm2.13445 |
_version_ | 1784613786453278720 |
---|---|
author | Frigo, Sean P. Ohrt, Jared Suh, Yelin Balter, Peter |
author_facet | Frigo, Sean P. Ohrt, Jared Suh, Yelin Balter, Peter |
author_sort | Frigo, Sean P. |
collection | PubMed |
description | A 6 MV flattened beam model for a Varian TrueBeamSTx c‐arm treatment delivery system in RayStation, developed and validated at one institution, was implemented and validated at another institution. The only parameter value adjustments were to accommodate machine output at the second institution. Validation followed MPPG 5.a. recommendations, with particular attention paid to IMRT and VMAT deliveries. With this minimal adjustment, the model passed validation across a broad spectrum of treatment plans, measurement devices, and staff who created the test plans and executed the measurements. This work demonstrates the possibility of using a single template model in the same treatment planning system with matched machines in a mixed vendor environment. |
format | Online Article Text |
id | pubmed-8664150 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86641502021-12-21 Interinstitutional beam model portability study in a mixed vendor environment Frigo, Sean P. Ohrt, Jared Suh, Yelin Balter, Peter J Appl Clin Med Phys Radiation Oncology Physics A 6 MV flattened beam model for a Varian TrueBeamSTx c‐arm treatment delivery system in RayStation, developed and validated at one institution, was implemented and validated at another institution. The only parameter value adjustments were to accommodate machine output at the second institution. Validation followed MPPG 5.a. recommendations, with particular attention paid to IMRT and VMAT deliveries. With this minimal adjustment, the model passed validation across a broad spectrum of treatment plans, measurement devices, and staff who created the test plans and executed the measurements. This work demonstrates the possibility of using a single template model in the same treatment planning system with matched machines in a mixed vendor environment. John Wiley and Sons Inc. 2021-10-13 /pmc/articles/PMC8664150/ /pubmed/34643323 http://dx.doi.org/10.1002/acm2.13445 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Frigo, Sean P. Ohrt, Jared Suh, Yelin Balter, Peter Interinstitutional beam model portability study in a mixed vendor environment |
title | Interinstitutional beam model portability study in a mixed vendor environment |
title_full | Interinstitutional beam model portability study in a mixed vendor environment |
title_fullStr | Interinstitutional beam model portability study in a mixed vendor environment |
title_full_unstemmed | Interinstitutional beam model portability study in a mixed vendor environment |
title_short | Interinstitutional beam model portability study in a mixed vendor environment |
title_sort | interinstitutional beam model portability study in a mixed vendor environment |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8664150/ https://www.ncbi.nlm.nih.gov/pubmed/34643323 http://dx.doi.org/10.1002/acm2.13445 |
work_keys_str_mv | AT frigoseanp interinstitutionalbeammodelportabilitystudyinamixedvendorenvironment AT ohrtjared interinstitutionalbeammodelportabilitystudyinamixedvendorenvironment AT suhyelin interinstitutionalbeammodelportabilitystudyinamixedvendorenvironment AT balterpeter interinstitutionalbeammodelportabilitystudyinamixedvendorenvironment |