Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics
Purpose: To evaluate the dependence of biomechanical metrics on intraocular pressure (IOP). Methods: 233 refractive surgery patients were included in this study—all were examined 3 times with the Corvis ST before and after dilation, and the differences (∆) in the main device parameters were assessed...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8664602/ https://www.ncbi.nlm.nih.gov/pubmed/34900957 http://dx.doi.org/10.3389/fbioe.2021.751628 |
_version_ | 1784613875009716224 |
---|---|
author | Ye, Yufeng Li, Yi Zhu, Zehui Abu Said, Anas Ziad Masoud Nguelemo Mayopa, Kevin Akiti, Stephen Huang, Chengyi Lopes, Bernardo T. Eliasy, Ashkan Miao, Yuanyuan Wang, Junjie Zheng, Xiaobo Chen, Shihao Bao, Fangjun Elsheikh, Ahmed |
author_facet | Ye, Yufeng Li, Yi Zhu, Zehui Abu Said, Anas Ziad Masoud Nguelemo Mayopa, Kevin Akiti, Stephen Huang, Chengyi Lopes, Bernardo T. Eliasy, Ashkan Miao, Yuanyuan Wang, Junjie Zheng, Xiaobo Chen, Shihao Bao, Fangjun Elsheikh, Ahmed |
author_sort | Ye, Yufeng |
collection | PubMed |
description | Purpose: To evaluate the dependence of biomechanical metrics on intraocular pressure (IOP). Methods: 233 refractive surgery patients were included in this study—all were examined 3 times with the Corvis ST before and after dilation, and the differences (∆) in the main device parameters were assessed. The data collected included the biomechanically corrected IOP (bIOP), the central corneal thickness (CCT), and six dynamic corneal response (DCR) parameters, namely DA, DARatio2mm, IIR, SP-A1, CBI, and SSI. Participants were divided into three groups according to the changes in patients’ bIOP after mydriasis. Results: Intra-operator repeatability was generally high in most of the DCR parameters obtained before and after dilation. The mean changes in bIOP and CCT after dilation were −0.12 ± 1.36 mmHg and 1.95 ± 5.23 μm, respectively. Only ∆DARatio2mm, ∆IIR, and ∆CBI exhibited a statistically significant correlation with ∆CCT (p < 0.05). The changes in all DCR parameters, especially ∆DA and ∆SP-A1 were also correlated with ∆bIOP (p < 0.01)—a 1-mmHg change in bIOP was associated, on average, with 5.612 and −0.037 units of change in SP-A1 and DA, respectively. In contrast, the weakest correlation with ∆bIOP was exhibited by ∆SSI. Conclusion: Most corneal DCR parameters, provided by the Corvis ST, were correlated with IOP, and more weakly with CCT. Changes experienced in CCT and IOP should therefore be considered in studies on corneal biomechanics and how it is affected by disease progression and surgical or medical procedures. |
format | Online Article Text |
id | pubmed-8664602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86646022021-12-11 Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics Ye, Yufeng Li, Yi Zhu, Zehui Abu Said, Anas Ziad Masoud Nguelemo Mayopa, Kevin Akiti, Stephen Huang, Chengyi Lopes, Bernardo T. Eliasy, Ashkan Miao, Yuanyuan Wang, Junjie Zheng, Xiaobo Chen, Shihao Bao, Fangjun Elsheikh, Ahmed Front Bioeng Biotechnol Bioengineering and Biotechnology Purpose: To evaluate the dependence of biomechanical metrics on intraocular pressure (IOP). Methods: 233 refractive surgery patients were included in this study—all were examined 3 times with the Corvis ST before and after dilation, and the differences (∆) in the main device parameters were assessed. The data collected included the biomechanically corrected IOP (bIOP), the central corneal thickness (CCT), and six dynamic corneal response (DCR) parameters, namely DA, DARatio2mm, IIR, SP-A1, CBI, and SSI. Participants were divided into three groups according to the changes in patients’ bIOP after mydriasis. Results: Intra-operator repeatability was generally high in most of the DCR parameters obtained before and after dilation. The mean changes in bIOP and CCT after dilation were −0.12 ± 1.36 mmHg and 1.95 ± 5.23 μm, respectively. Only ∆DARatio2mm, ∆IIR, and ∆CBI exhibited a statistically significant correlation with ∆CCT (p < 0.05). The changes in all DCR parameters, especially ∆DA and ∆SP-A1 were also correlated with ∆bIOP (p < 0.01)—a 1-mmHg change in bIOP was associated, on average, with 5.612 and −0.037 units of change in SP-A1 and DA, respectively. In contrast, the weakest correlation with ∆bIOP was exhibited by ∆SSI. Conclusion: Most corneal DCR parameters, provided by the Corvis ST, were correlated with IOP, and more weakly with CCT. Changes experienced in CCT and IOP should therefore be considered in studies on corneal biomechanics and how it is affected by disease progression and surgical or medical procedures. Frontiers Media S.A. 2021-11-26 /pmc/articles/PMC8664602/ /pubmed/34900957 http://dx.doi.org/10.3389/fbioe.2021.751628 Text en Copyright © 2021 Ye, Li, Zhu, Abu Said, Nguelemo Mayopa, Akiti, Huang, Lopes, Eliasy, Miao, Wang, Zheng, Chen, Bao and Elsheikh. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Ye, Yufeng Li, Yi Zhu, Zehui Abu Said, Anas Ziad Masoud Nguelemo Mayopa, Kevin Akiti, Stephen Huang, Chengyi Lopes, Bernardo T. Eliasy, Ashkan Miao, Yuanyuan Wang, Junjie Zheng, Xiaobo Chen, Shihao Bao, Fangjun Elsheikh, Ahmed Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics |
title | Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics |
title_full | Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics |
title_fullStr | Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics |
title_full_unstemmed | Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics |
title_short | Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics |
title_sort | effect of mydriasis-caused intraocular pressure changes on corneal biomechanical metrics |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8664602/ https://www.ncbi.nlm.nih.gov/pubmed/34900957 http://dx.doi.org/10.3389/fbioe.2021.751628 |
work_keys_str_mv | AT yeyufeng effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT liyi effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT zhuzehui effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT abusaidanasziadmasoud effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT nguelemomayopakevin effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT akitistephen effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT huangchengyi effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT lopesbernardot effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT eliasyashkan effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT miaoyuanyuan effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT wangjunjie effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT zhengxiaobo effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT chenshihao effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT baofangjun effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics AT elsheikhahmed effectofmydriasiscausedintraocularpressurechangesoncornealbiomechanicalmetrics |