Cargando…

Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty

BACKGROUND: Clinical outcomes of kinematically aligned total knee arthroplasty (KA-TKA) have been reported as comparable or superior to those of mechanically aligned TKA (MA-TKA). However, cruciate-retaining prostheses have mostly been used for KA-TKA. This study used medial pivot knee prostheses fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaneda, Kazuya, Niki, Yasuo, Kuroyanagi, Yuji, Kobayashi, Shu, Harato, Kengo, Iwama, Yu, Nagura, Takeo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8666599/
https://www.ncbi.nlm.nih.gov/pubmed/34917717
http://dx.doi.org/10.1016/j.artd.2021.10.004
_version_ 1784614243206692864
author Kaneda, Kazuya
Niki, Yasuo
Kuroyanagi, Yuji
Kobayashi, Shu
Harato, Kengo
Iwama, Yu
Nagura, Takeo
author_facet Kaneda, Kazuya
Niki, Yasuo
Kuroyanagi, Yuji
Kobayashi, Shu
Harato, Kengo
Iwama, Yu
Nagura, Takeo
author_sort Kaneda, Kazuya
collection PubMed
description BACKGROUND: Clinical outcomes of kinematically aligned total knee arthroplasty (KA-TKA) have been reported as comparable or superior to those of mechanically aligned TKA (MA-TKA). However, cruciate-retaining prostheses have mostly been used for KA-TKA. This study used medial pivot knee prostheses for KA-TKA, and knee kinematics after KA-TKA were assessed and compared with those after MA-TKA. METHODS: Thirteen knees in 9 patients undergoing primary TKA (8 KAs, 5 MAs) were subjected to two-dimensional (2D) to three-dimensional (3D) registration analysis at 1 year postoperatively. Each patient performed weight-bearing activities, and movements were recorded as intermittent digital radiographic images. Three-dimensional implant positions during activities were analyzed for anterior-posterior translation in the sagittal plane, condylar liftoff and mediolateral translation in the coronal plane, and femoral rotation in the axial plane. RESULTS: Posterior translation of the lateral femoral condyle from 0° to 100° was larger in KA-TKA than in MA-TKA (P = .006). The degrees of condylar liftoff and mediolateral translation were comparable between TKAs. Total external rotation of the femoral component relative to tibial component was significantly greater for KA-TKA (7.7 ± 5.2°) than for MA-TKA (1.3 ± 3.3°; P = .03). The kinematic path of the femoral component revealed greater medial pivoting motion in KA-TKA than in MA-TKA. CONCLUSIONS: KA-TKA using a medial pivot knee prosthesis successfully reproduced the medial pivot pattern and achieved larger femoral external rotation relative to the tibia than MA-TKA. KA-TKA was able to maximize the primary concept of the medial pivot knee prosthesis.
format Online
Article
Text
id pubmed-8666599
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86665992021-12-15 Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty Kaneda, Kazuya Niki, Yasuo Kuroyanagi, Yuji Kobayashi, Shu Harato, Kengo Iwama, Yu Nagura, Takeo Arthroplast Today Original Research BACKGROUND: Clinical outcomes of kinematically aligned total knee arthroplasty (KA-TKA) have been reported as comparable or superior to those of mechanically aligned TKA (MA-TKA). However, cruciate-retaining prostheses have mostly been used for KA-TKA. This study used medial pivot knee prostheses for KA-TKA, and knee kinematics after KA-TKA were assessed and compared with those after MA-TKA. METHODS: Thirteen knees in 9 patients undergoing primary TKA (8 KAs, 5 MAs) were subjected to two-dimensional (2D) to three-dimensional (3D) registration analysis at 1 year postoperatively. Each patient performed weight-bearing activities, and movements were recorded as intermittent digital radiographic images. Three-dimensional implant positions during activities were analyzed for anterior-posterior translation in the sagittal plane, condylar liftoff and mediolateral translation in the coronal plane, and femoral rotation in the axial plane. RESULTS: Posterior translation of the lateral femoral condyle from 0° to 100° was larger in KA-TKA than in MA-TKA (P = .006). The degrees of condylar liftoff and mediolateral translation were comparable between TKAs. Total external rotation of the femoral component relative to tibial component was significantly greater for KA-TKA (7.7 ± 5.2°) than for MA-TKA (1.3 ± 3.3°; P = .03). The kinematic path of the femoral component revealed greater medial pivoting motion in KA-TKA than in MA-TKA. CONCLUSIONS: KA-TKA using a medial pivot knee prosthesis successfully reproduced the medial pivot pattern and achieved larger femoral external rotation relative to the tibia than MA-TKA. KA-TKA was able to maximize the primary concept of the medial pivot knee prosthesis. Elsevier 2021-12-10 /pmc/articles/PMC8666599/ /pubmed/34917717 http://dx.doi.org/10.1016/j.artd.2021.10.004 Text en © 2021 Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Kaneda, Kazuya
Niki, Yasuo
Kuroyanagi, Yuji
Kobayashi, Shu
Harato, Kengo
Iwama, Yu
Nagura, Takeo
Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
title Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
title_full Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
title_fullStr Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
title_full_unstemmed Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
title_short Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
title_sort kinematically aligned total knee arthroplasty using medial pivot knee prosthesis enhances medial pivot motion: a comparative kinematic study with mechanically aligned total knee arthroplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8666599/
https://www.ncbi.nlm.nih.gov/pubmed/34917717
http://dx.doi.org/10.1016/j.artd.2021.10.004
work_keys_str_mv AT kanedakazuya kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty
AT nikiyasuo kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty
AT kuroyanagiyuji kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty
AT kobayashishu kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty
AT haratokengo kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty
AT iwamayu kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty
AT naguratakeo kinematicallyalignedtotalkneearthroplastyusingmedialpivotkneeprosthesisenhancesmedialpivotmotionacomparativekinematicstudywithmechanicallyalignedtotalkneearthroplasty