A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens

Early and accurate detection of SARS-CoV-2 is important for diagnosis and transmission control. The use of high-throughput and automated testing allows laboratories to better deliver diagnostic testing given manpower and resource limitations. We validated the clinical and analytical performance of t...

Descripción completa

Detalles Bibliográficos
Autores principales: La, My-Van, Koo, Seok Hwee, Jiang, Boran, Heng, Ying Xuan, Tan, Thean Yen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8669225/
https://www.ncbi.nlm.nih.gov/pubmed/34905087
http://dx.doi.org/10.1007/s00284-021-02730-3
_version_ 1784614738391465984
author La, My-Van
Koo, Seok Hwee
Jiang, Boran
Heng, Ying Xuan
Tan, Thean Yen
author_facet La, My-Van
Koo, Seok Hwee
Jiang, Boran
Heng, Ying Xuan
Tan, Thean Yen
author_sort La, My-Van
collection PubMed
description Early and accurate detection of SARS-CoV-2 is important for diagnosis and transmission control. The use of high-throughput and automated testing allows laboratories to better deliver diagnostic testing given manpower and resource limitations. We validated the clinical and analytical performance of the Hologic Panther Aptima SARS-CoV-2 assay with an emphasis on detection of specimens with low viral loads. The clinical performance was evaluated using 245 clinical specimens, against a comparator PCR-based laboratory developed test (LDT). The analytical performance was determined by replicate testing of contrived samples in a ten-fold dilution series (C(T) values 32–42, based on LDT). The Aptima assay had 96.7% overall percent agreement, 100% negative percent agreement and 88.1% positive percent agreement. It was able to consistently detect SARS-CoV-2 in contrived samples with C(T) = 32 by LDT (calculated 2354 copies/mL). The 95% limit of detection of the Aptima assay was estimated to be at LDT C(T) = 33 (equivalent to 870 copies/mL). The relative light units (RLU) × 1000 for 52 true positive clinical specimens was 962.2 ± 181.5, and that for the 186 true negative specimens was 264.6 ± 14.3. The Aptima assay was a reliable method with a high overall percent agreement against our comparator LDT. We propose that samples reported as negative by the Aptima assay with RLU > 350 be tested by a secondary method, in order to improve detection of samples with very low viral loads. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00284-021-02730-3.
format Online
Article
Text
id pubmed-8669225
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-86692252021-12-14 A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens La, My-Van Koo, Seok Hwee Jiang, Boran Heng, Ying Xuan Tan, Thean Yen Curr Microbiol Short Communication Early and accurate detection of SARS-CoV-2 is important for diagnosis and transmission control. The use of high-throughput and automated testing allows laboratories to better deliver diagnostic testing given manpower and resource limitations. We validated the clinical and analytical performance of the Hologic Panther Aptima SARS-CoV-2 assay with an emphasis on detection of specimens with low viral loads. The clinical performance was evaluated using 245 clinical specimens, against a comparator PCR-based laboratory developed test (LDT). The analytical performance was determined by replicate testing of contrived samples in a ten-fold dilution series (C(T) values 32–42, based on LDT). The Aptima assay had 96.7% overall percent agreement, 100% negative percent agreement and 88.1% positive percent agreement. It was able to consistently detect SARS-CoV-2 in contrived samples with C(T) = 32 by LDT (calculated 2354 copies/mL). The 95% limit of detection of the Aptima assay was estimated to be at LDT C(T) = 33 (equivalent to 870 copies/mL). The relative light units (RLU) × 1000 for 52 true positive clinical specimens was 962.2 ± 181.5, and that for the 186 true negative specimens was 264.6 ± 14.3. The Aptima assay was a reliable method with a high overall percent agreement against our comparator LDT. We propose that samples reported as negative by the Aptima assay with RLU > 350 be tested by a secondary method, in order to improve detection of samples with very low viral loads. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00284-021-02730-3. Springer US 2021-12-14 2022 /pmc/articles/PMC8669225/ /pubmed/34905087 http://dx.doi.org/10.1007/s00284-021-02730-3 Text en © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Short Communication
La, My-Van
Koo, Seok Hwee
Jiang, Boran
Heng, Ying Xuan
Tan, Thean Yen
A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens
title A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens
title_full A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens
title_fullStr A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens
title_full_unstemmed A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens
title_short A Study of Analytical and Clinical Sensitivity of Aptima SARS-CoV-2 Assay (Hologic) and Proposals of Complementary Tests for SARS-CoV-2 Detection in Low Viral Load Specimens
title_sort study of analytical and clinical sensitivity of aptima sars-cov-2 assay (hologic) and proposals of complementary tests for sars-cov-2 detection in low viral load specimens
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8669225/
https://www.ncbi.nlm.nih.gov/pubmed/34905087
http://dx.doi.org/10.1007/s00284-021-02730-3
work_keys_str_mv AT lamyvan astudyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT kooseokhwee astudyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT jiangboran astudyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT hengyingxuan astudyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT tantheanyen astudyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT lamyvan studyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT kooseokhwee studyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT jiangboran studyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT hengyingxuan studyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens
AT tantheanyen studyofanalyticalandclinicalsensitivityofaptimasarscov2assayhologicandproposalsofcomplementarytestsforsarscov2detectioninlowviralloadspecimens