Cargando…
A LC-MS/MS method with electrospray ionization and atmospheric pressure chemical ionization source for analysis of pesticides in hemp
BACKGROUND: Pesticide testing for hemp has traditionally focused on techniques like QuEChERS with dSPE and SPE which demand time-consuming sample preparation, typically resulting in poor recovery rates for some pesticides, and requires the use of both LC-MS/MS and GC-MS/MS based instruments to cover...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8670113/ https://www.ncbi.nlm.nih.gov/pubmed/34903307 http://dx.doi.org/10.1186/s42238-021-00106-9 |
Sumario: | BACKGROUND: Pesticide testing for hemp has traditionally focused on techniques like QuEChERS with dSPE and SPE which demand time-consuming sample preparation, typically resulting in poor recovery rates for some pesticides, and requires the use of both LC-MS/MS and GC-MS/MS based instruments to cover the analysis for all regulated pesticides. In this study, we describe a streamlined approach for working with LC-MS/MS featuring a dual electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources using solvent extraction for faster and easier sample preparation and with 80–120% recovery for the analysis of all of 66 pesticides (regulated by California state in cannabis) with low detection limits in hemp. METHODS: A simple solvent extraction with acetonitrile was used to extract pesticides from hemp. A LC-MS/MS system with dual ESI and APCI source was used to determine sensitivity for the analysis of 66 pesticides in hemp matrix, 62 pesticides were analyzed using an 18-min LC-MS/MS method with an ESI source and the other 4 pesticides were measured using a 6-min LC-MS/MS method with an APCI source. RESULTS: The limit of quantitation (LOQ) of all 66 pesticides in hemp was in the range of 0.0025–0.1 μg/g which was well below the California state action limits of these analytes in cannabis products. A simple, fast, and cost-effective solvent extraction method was used for sample preparation to get good recovery in the range of 80–120% with RSD less than 20%. The unique ionization mechanism of chlorinated pesticides such as pentachloronitrobenzene using the LC-MS/MS system with an APCI source was elucidated. The proficiency test report generated with the LC-MS/MS method showed acceptable results for all of 66 pesticides in hemp with all of th z scores less than 2 with no false positives and negatives. The stability data collected over 5 days showed RSD less than 20% for 66 pesticides in hemp, and this demonstrated the robustness of the LC-MS/MS system used in this work. CONCLUSIONS: A LC-MS/MS method with dual ESI and APCI sources was developed for the analysis of 66 pesticides in hemp. The recovery of all pesticides from a hemp matrix was in the acceptable range of 80–120% with RSD less than 20%. |
---|