Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study
Background: Inspiratory loading is experienced by military divers when they use rebreather device. Our objective was to assess the changes in diaphragm function induced by an increase in inspiratory load at values similar to those experienced by divers in real life. Methods: We recorded the excursio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8670941/ https://www.ncbi.nlm.nih.gov/pubmed/34916955 http://dx.doi.org/10.3389/fphys.2021.756533 |
_version_ | 1784615062205366272 |
---|---|
author | Rives, Sarah Schmid, Bruno Chaumet, Guillaume Brégeon, Fabienne Boussuges, Alain |
author_facet | Rives, Sarah Schmid, Bruno Chaumet, Guillaume Brégeon, Fabienne Boussuges, Alain |
author_sort | Rives, Sarah |
collection | PubMed |
description | Background: Inspiratory loading is experienced by military divers when they use rebreather device. Our objective was to assess the changes in diaphragm function induced by an increase in inspiratory load at values similar to those experienced by divers in real life. Methods: We recorded the excursion and the thickness of the right hemidiaphragm in 22 healthy male volunteers under inspiratory load conditions, using ultrasound in B- and M-mode. The measurements were performed at tidal volume and during breathing at 50% of inspiratory capacity. The breathing rate was regulated and similar in the various sessions with and without load. Results: The rebreather device used by French military divers leads to an increase in inspiratory load of close to 30 cmH(2)O. Consequently, the session under load was performed using a device set to this threshold. Significant increases in the excursion and the thickening fraction of the diaphragm were observed between the sessions at tidal volume and at high volume. With addition of the inspiratory load, the excursion of the right hemidiaphragm increased significantly from 2.3 to 3.4cm at tidal volume and from 3.9 to 4.7cm at high volume. The thickening fraction increased significantly from 30.4 to 76.6% at tidal volume and from 70 to 123% at high volume. The statistical analysis demonstrated that assessment of the changes of the thickening fraction during breathing at tidal volume was the most relevant marker to assess the impact of the inspiratory load on the diaphragm. Conclusion: Diaphragm ultrasound can be used to assess the changes in the diaphragm contraction pattern secondary to an increase in the respiratory load that can be generated by use a diving apparatus. The recording of the changes of the motion, and more importantly of the thickness of the diaphragm, during the breathing cycle is able to provide relevant information regarding the inspiratory load. |
format | Online Article Text |
id | pubmed-8670941 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86709412021-12-15 Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study Rives, Sarah Schmid, Bruno Chaumet, Guillaume Brégeon, Fabienne Boussuges, Alain Front Physiol Physiology Background: Inspiratory loading is experienced by military divers when they use rebreather device. Our objective was to assess the changes in diaphragm function induced by an increase in inspiratory load at values similar to those experienced by divers in real life. Methods: We recorded the excursion and the thickness of the right hemidiaphragm in 22 healthy male volunteers under inspiratory load conditions, using ultrasound in B- and M-mode. The measurements were performed at tidal volume and during breathing at 50% of inspiratory capacity. The breathing rate was regulated and similar in the various sessions with and without load. Results: The rebreather device used by French military divers leads to an increase in inspiratory load of close to 30 cmH(2)O. Consequently, the session under load was performed using a device set to this threshold. Significant increases in the excursion and the thickening fraction of the diaphragm were observed between the sessions at tidal volume and at high volume. With addition of the inspiratory load, the excursion of the right hemidiaphragm increased significantly from 2.3 to 3.4cm at tidal volume and from 3.9 to 4.7cm at high volume. The thickening fraction increased significantly from 30.4 to 76.6% at tidal volume and from 70 to 123% at high volume. The statistical analysis demonstrated that assessment of the changes of the thickening fraction during breathing at tidal volume was the most relevant marker to assess the impact of the inspiratory load on the diaphragm. Conclusion: Diaphragm ultrasound can be used to assess the changes in the diaphragm contraction pattern secondary to an increase in the respiratory load that can be generated by use a diving apparatus. The recording of the changes of the motion, and more importantly of the thickness of the diaphragm, during the breathing cycle is able to provide relevant information regarding the inspiratory load. Frontiers Media S.A. 2021-11-30 /pmc/articles/PMC8670941/ /pubmed/34916955 http://dx.doi.org/10.3389/fphys.2021.756533 Text en Copyright © 2021 Rives, Schmid, Chaumet, Brégeon and Boussuges. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Rives, Sarah Schmid, Bruno Chaumet, Guillaume Brégeon, Fabienne Boussuges, Alain Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study |
title | Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study |
title_full | Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study |
title_fullStr | Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study |
title_full_unstemmed | Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study |
title_short | Changes in Diaphragmatic Function Induced by an Increased Inspiratory Load Experienced by Military Divers: An Ultrasound Study |
title_sort | changes in diaphragmatic function induced by an increased inspiratory load experienced by military divers: an ultrasound study |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8670941/ https://www.ncbi.nlm.nih.gov/pubmed/34916955 http://dx.doi.org/10.3389/fphys.2021.756533 |
work_keys_str_mv | AT rivessarah changesindiaphragmaticfunctioninducedbyanincreasedinspiratoryloadexperiencedbymilitarydiversanultrasoundstudy AT schmidbruno changesindiaphragmaticfunctioninducedbyanincreasedinspiratoryloadexperiencedbymilitarydiversanultrasoundstudy AT chaumetguillaume changesindiaphragmaticfunctioninducedbyanincreasedinspiratoryloadexperiencedbymilitarydiversanultrasoundstudy AT bregeonfabienne changesindiaphragmaticfunctioninducedbyanincreasedinspiratoryloadexperiencedbymilitarydiversanultrasoundstudy AT boussugesalain changesindiaphragmaticfunctioninducedbyanincreasedinspiratoryloadexperiencedbymilitarydiversanultrasoundstudy |