Cargando…
On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation
Computational physiological models are promising tools to enhance the design of clinical trials and to assist in decision making. Organ-scale haemodynamic models are gaining popularity to evaluate perfusion in a virtual environment both in healthy and diseased patients. Recently, the principles of v...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8671295/ https://www.ncbi.nlm.nih.gov/pubmed/34155569 http://dx.doi.org/10.1007/s10439-021-02808-w |
_version_ | 1784615117453787136 |
---|---|
author | Józsa, T. I. Padmos, R. M. El-Bouri, W. K. Hoekstra, A. G. Payne, S. J. |
author_facet | Józsa, T. I. Padmos, R. M. El-Bouri, W. K. Hoekstra, A. G. Payne, S. J. |
author_sort | Józsa, T. I. |
collection | PubMed |
description | Computational physiological models are promising tools to enhance the design of clinical trials and to assist in decision making. Organ-scale haemodynamic models are gaining popularity to evaluate perfusion in a virtual environment both in healthy and diseased patients. Recently, the principles of verification, validation, and uncertainty quantification of such physiological models have been laid down to ensure safe applications of engineering software in the medical device industry. The present study sets out to establish guidelines for the usage of a three-dimensional steady state porous cerebral perfusion model of the human brain following principles detailed in the verification and validation (V&V 40) standard of the American Society of Mechanical Engineers. The model relies on the finite element method and has been developed specifically to estimate how brain perfusion is altered in ischaemic stroke patients before, during, and after treatments. Simulations are compared with exact analytical solutions and a thorough sensitivity analysis is presented covering every numerical and physiological model parameter. The results suggest that such porous models can approximate blood pressure and perfusion distributions reliably even on a coarse grid with first order elements. On the other hand, higher order elements are essential to mitigate errors in volumetric blood flow rate estimation through cortical surface regions. Matching the volumetric flow rate corresponding to major cerebral arteries is identified as a validation milestone. It is found that inlet velocity boundary conditions are hard to obtain and that constant pressure inlet boundary conditions are feasible alternatives. A one-dimensional model is presented which can serve as a computationally inexpensive replacement of the three-dimensional brain model to ease parameter optimisation, sensitivity analyses and uncertainty quantification. The findings of the present study can be generalised to organ-scale porous perfusion models. The results increase the applicability of computational tools regarding treatment development for stroke and other cerebrovascular conditions. |
format | Online Article Text |
id | pubmed-8671295 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-86712952021-12-28 On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation Józsa, T. I. Padmos, R. M. El-Bouri, W. K. Hoekstra, A. G. Payne, S. J. Ann Biomed Eng Virtual Physiological Human Computational physiological models are promising tools to enhance the design of clinical trials and to assist in decision making. Organ-scale haemodynamic models are gaining popularity to evaluate perfusion in a virtual environment both in healthy and diseased patients. Recently, the principles of verification, validation, and uncertainty quantification of such physiological models have been laid down to ensure safe applications of engineering software in the medical device industry. The present study sets out to establish guidelines for the usage of a three-dimensional steady state porous cerebral perfusion model of the human brain following principles detailed in the verification and validation (V&V 40) standard of the American Society of Mechanical Engineers. The model relies on the finite element method and has been developed specifically to estimate how brain perfusion is altered in ischaemic stroke patients before, during, and after treatments. Simulations are compared with exact analytical solutions and a thorough sensitivity analysis is presented covering every numerical and physiological model parameter. The results suggest that such porous models can approximate blood pressure and perfusion distributions reliably even on a coarse grid with first order elements. On the other hand, higher order elements are essential to mitigate errors in volumetric blood flow rate estimation through cortical surface regions. Matching the volumetric flow rate corresponding to major cerebral arteries is identified as a validation milestone. It is found that inlet velocity boundary conditions are hard to obtain and that constant pressure inlet boundary conditions are feasible alternatives. A one-dimensional model is presented which can serve as a computationally inexpensive replacement of the three-dimensional brain model to ease parameter optimisation, sensitivity analyses and uncertainty quantification. The findings of the present study can be generalised to organ-scale porous perfusion models. The results increase the applicability of computational tools regarding treatment development for stroke and other cerebrovascular conditions. Springer International Publishing 2021-06-21 2021 /pmc/articles/PMC8671295/ /pubmed/34155569 http://dx.doi.org/10.1007/s10439-021-02808-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Virtual Physiological Human Józsa, T. I. Padmos, R. M. El-Bouri, W. K. Hoekstra, A. G. Payne, S. J. On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation |
title | On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation |
title_full | On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation |
title_fullStr | On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation |
title_full_unstemmed | On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation |
title_short | On the Sensitivity Analysis of Porous Finite Element Models for Cerebral Perfusion Estimation |
title_sort | on the sensitivity analysis of porous finite element models for cerebral perfusion estimation |
topic | Virtual Physiological Human |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8671295/ https://www.ncbi.nlm.nih.gov/pubmed/34155569 http://dx.doi.org/10.1007/s10439-021-02808-w |
work_keys_str_mv | AT jozsati onthesensitivityanalysisofporousfiniteelementmodelsforcerebralperfusionestimation AT padmosrm onthesensitivityanalysisofporousfiniteelementmodelsforcerebralperfusionestimation AT elbouriwk onthesensitivityanalysisofporousfiniteelementmodelsforcerebralperfusionestimation AT hoekstraag onthesensitivityanalysisofporousfiniteelementmodelsforcerebralperfusionestimation AT paynesj onthesensitivityanalysisofporousfiniteelementmodelsforcerebralperfusionestimation |