Cargando…

Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study

BACKGROUND: Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. METHODS: The polyethylene of a dual mobility acetabular system wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Jørgensen, Peter Bo, Kaptein, Bart L., Søballe, Kjeld, Jakobsen, Stig S., Stilling, Maiken
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8671599/
https://www.ncbi.nlm.nih.gov/pubmed/34907467
http://dx.doi.org/10.1186/s41747-021-00253-x
_version_ 1784615170893414400
author Jørgensen, Peter Bo
Kaptein, Bart L.
Søballe, Kjeld
Jakobsen, Stig S.
Stilling, Maiken
author_facet Jørgensen, Peter Bo
Kaptein, Bart L.
Søballe, Kjeld
Jakobsen, Stig S.
Stilling, Maiken
author_sort Jørgensen, Peter Bo
collection PubMed
description BACKGROUND: Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. METHODS: The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model. RESULTS: The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly. CONCLUSION: Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model. TRIAL REGISTRATION: ClinicalTrials.gov [NCT02301182], 25 October 2015. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41747-021-00253-x.
format Online
Article
Text
id pubmed-8671599
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-86715992021-12-17 Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study Jørgensen, Peter Bo Kaptein, Bart L. Søballe, Kjeld Jakobsen, Stig S. Stilling, Maiken Eur Radiol Exp Original Article BACKGROUND: Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. METHODS: The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model. RESULTS: The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly. CONCLUSION: Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model. TRIAL REGISTRATION: ClinicalTrials.gov [NCT02301182], 25 October 2015. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41747-021-00253-x. Springer International Publishing 2021-12-15 /pmc/articles/PMC8671599/ /pubmed/34907467 http://dx.doi.org/10.1186/s41747-021-00253-x Text en © The Author(s) under exclusive licence to European Society of Radiology 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Jørgensen, Peter Bo
Kaptein, Bart L.
Søballe, Kjeld
Jakobsen, Stig S.
Stilling, Maiken
Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
title Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
title_full Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
title_fullStr Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
title_full_unstemmed Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
title_short Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
title_sort combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8671599/
https://www.ncbi.nlm.nih.gov/pubmed/34907467
http://dx.doi.org/10.1186/s41747-021-00253-x
work_keys_str_mv AT jørgensenpeterbo combinedandhybridmarkermodelsforradiostereometryassessmentofpolyethylenelinermotionindualmobilityhipprosthesisaproofofconceptstudy
AT kapteinbartl combinedandhybridmarkermodelsforradiostereometryassessmentofpolyethylenelinermotionindualmobilityhipprosthesisaproofofconceptstudy
AT søballekjeld combinedandhybridmarkermodelsforradiostereometryassessmentofpolyethylenelinermotionindualmobilityhipprosthesisaproofofconceptstudy
AT jakobsenstigs combinedandhybridmarkermodelsforradiostereometryassessmentofpolyethylenelinermotionindualmobilityhipprosthesisaproofofconceptstudy
AT stillingmaiken combinedandhybridmarkermodelsforradiostereometryassessmentofpolyethylenelinermotionindualmobilityhipprosthesisaproofofconceptstudy