COVID-19 outbreak: Should dental and medical practices consider uv-c technology to enhance disinfection on surfaces? – A systematic review
AIMS: During the COVID-19 pandemic the search for complementary methods to enhance manual disinfection in dental and medical practices raised relevance. We sought evidence for the addition of ultraviolet-C (UV-C) disinfection to manual cleaning protocols –and whether it improves the logarithmic (log...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Author(s). Published by Elsevier B.V.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8674638/ https://www.ncbi.nlm.nih.gov/pubmed/34931181 http://dx.doi.org/10.1016/j.jpap.2021.100096 |
Sumario: | AIMS: During the COVID-19 pandemic the search for complementary methods to enhance manual disinfection in dental and medical practices raised relevance. We sought evidence for the addition of ultraviolet-C (UV-C) disinfection to manual cleaning protocols –and whether it improves the logarithmic (log) reduction of surface pathogen colonies. METHODS: This review was registered at the International Prospective Register of Systematic Reviews (PROSPERO) under the number CRD420200193961. Six electronic sources were consulted looking for clinical trials performed in healthcare environments in which pathogens were quantified by colony-forming unit (CFU)-enumeration before and after interventions, all databases were last consulted on May 2021. We assessed the risk of bias using an adapted Revised Cochrane Risk of Bias Tool (RoB 2). The certainty of the evidence was qualified according to the Classification of Recommendations, Evaluation, Development, and Evaluation (GRADE) approach. RESULTS: We identified 1012 records and 12 studies fulfilled the inclusion criteria. All included studies reported enhanced disinfection in the UV-C arm; most of them reported 1-log to 2-log reduction in approximately 10 to 25 min. Only three studies reached a 5-log and 6-log reduction. When manual cleaning was performed alone, only two studies reported a 1-log reduction using a chlorine-based disinfectant. We detected a high risk of bias in 1 study. Certainty of evidence was classified as moderate and low. CONCLUSIONS: The evidence points out the effectiveness of UV-C technology in reducing manual cleaning failures, enhancing the logarithmic reduction of surface pathogen colonies. However, the safety and success of these devices will depend on several physical and biological factors. A judicious project must precede their use in clinical and medical offices under the supervision of a physicist or other trained professional. |
---|