Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primar...

Descripción completa

Detalles Bibliográficos
Autores principales: Qing, Ming, Qiu, Yue, Wang, Jiarong, Zheng, Tinghui, Yuan, Ding
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8674644/
https://www.ncbi.nlm.nih.gov/pubmed/34925075
http://dx.doi.org/10.3389/fphys.2021.795085
_version_ 1784615717396545536
author Qing, Ming
Qiu, Yue
Wang, Jiarong
Zheng, Tinghui
Yuan, Ding
author_facet Qing, Ming
Qiu, Yue
Wang, Jiarong
Zheng, Tinghui
Yuan, Ding
author_sort Qing, Ming
collection PubMed
description Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primarily utilized simplified planar neck geometries. This study examined the differences in flow patterns and hemodynamic parameters between crossed and non-crossed limb SGs at different spatial neck angulations. Methods: Ideal models consisting of 13 cross and 13 non-cross limbs were established, with coronal and sagittal angles ranging from 0 to 90°. Computational fluid dynamics (CFD) was used to capture the hemodynamic information, and the differences were compared. Results: With regards to the pressure drop index, the maximum difference caused by the configuration and angular direction was 4.6 and 8.0%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 27.1%. With regards to the SAR-TAWSS index, the maximum difference caused by the configuration and angular direction was 7.8 and 9.8%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 26.7%. In addition, when the aneurysm neck angle is lower than 45°, the configuration and angular direction significantly influence the OSI and helical flow intensity index. However, when the aneurysm neck angle is greater than 45°, the hemodynamic differences of each model at the same aneurysm neck angle are reduced. Conclusion: The main factor affecting the hemodynamic index was the angle of the aneurysm neck, while the configuration and angular direction had little effect on the hemodynamics. Furthermore, when the aneurysm neck was greatly angulated, the cross-limb technique did not increase the risk of thrombosis.
format Online
Article
Text
id pubmed-8674644
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86746442021-12-17 A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck Qing, Ming Qiu, Yue Wang, Jiarong Zheng, Tinghui Yuan, Ding Front Physiol Physiology Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primarily utilized simplified planar neck geometries. This study examined the differences in flow patterns and hemodynamic parameters between crossed and non-crossed limb SGs at different spatial neck angulations. Methods: Ideal models consisting of 13 cross and 13 non-cross limbs were established, with coronal and sagittal angles ranging from 0 to 90°. Computational fluid dynamics (CFD) was used to capture the hemodynamic information, and the differences were compared. Results: With regards to the pressure drop index, the maximum difference caused by the configuration and angular direction was 4.6 and 8.0%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 27.1%. With regards to the SAR-TAWSS index, the maximum difference caused by the configuration and angular direction was 7.8 and 9.8%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 26.7%. In addition, when the aneurysm neck angle is lower than 45°, the configuration and angular direction significantly influence the OSI and helical flow intensity index. However, when the aneurysm neck angle is greater than 45°, the hemodynamic differences of each model at the same aneurysm neck angle are reduced. Conclusion: The main factor affecting the hemodynamic index was the angle of the aneurysm neck, while the configuration and angular direction had little effect on the hemodynamics. Furthermore, when the aneurysm neck was greatly angulated, the cross-limb technique did not increase the risk of thrombosis. Frontiers Media S.A. 2021-12-02 /pmc/articles/PMC8674644/ /pubmed/34925075 http://dx.doi.org/10.3389/fphys.2021.795085 Text en Copyright © 2021 Qing, Qiu, Wang, Zheng and Yuan. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Qing, Ming
Qiu, Yue
Wang, Jiarong
Zheng, Tinghui
Yuan, Ding
A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck
title A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck
title_full A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck
title_fullStr A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck
title_full_unstemmed A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck
title_short A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck
title_sort comparative study on the hemodynamic performance within cross and non-cross stent-grafts for abdominal aortic aneurysms with an angulated neck
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8674644/
https://www.ncbi.nlm.nih.gov/pubmed/34925075
http://dx.doi.org/10.3389/fphys.2021.795085
work_keys_str_mv AT qingming acomparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT qiuyue acomparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT wangjiarong acomparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT zhengtinghui acomparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT yuanding acomparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT qingming comparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT qiuyue comparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT wangjiarong comparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT zhengtinghui comparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck
AT yuanding comparativestudyonthehemodynamicperformancewithincrossandnoncrossstentgraftsforabdominalaorticaneurysmswithanangulatedneck