Cargando…

Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring

We present in this paper an in-depth study and analysis of bronchiectasis haemoptysis by multirow CT tomography and a multifaceted treatment and analysis of the interventions monitored by the scan. Although coronary CT is of great clinical value in the diagnosis and monitoring of coronary artery dis...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, DongDong, Chai, Wenshu, Gao, Xue, Yan, Xue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8677367/
https://www.ncbi.nlm.nih.gov/pubmed/34925743
http://dx.doi.org/10.1155/2021/9116765
_version_ 1784616131854598144
author Lu, DongDong
Chai, Wenshu
Gao, Xue
Yan, Xue
author_facet Lu, DongDong
Chai, Wenshu
Gao, Xue
Yan, Xue
author_sort Lu, DongDong
collection PubMed
description We present in this paper an in-depth study and analysis of bronchiectasis haemoptysis by multirow CT tomography and a multifaceted treatment and analysis of the interventions monitored by the scan. Although coronary CT is of great clinical value in the diagnosis and monitoring of coronary artery disease, the potential radiation damage caused by coronary CT should not be underestimated because CT imaging is based on X-rays and the actual effective dose is 5–30 mSv, which is reported in the literature to be high when using conventional imaging modalities for coronary CT. Although there is no direct evidence of a definite causal relationship between X-ray exposure during CT examinations and tumorigenesis, theoretically, even small doses of radiation exposure may pose some potential health risk. Therefore, in clinical practice, coronary CT examinations should be performed in strict compliance with the radiation protection rule “as low as reasonably achievable” (ALARA) recognized by the radiation industry. For longitudinal openings in the range of 0° to 59° and transverse openings in the range of 0° to 44°, the CB2 catheter is significantly more stable than the MIK catheter, and for longitudinal openings in the range of 60° to 119° and transverse openings in the range of 0° to 44°, the CB2 catheter is more stable than the MIK catheter. For longitudinal openings from 0° to 120° and lateral openings from 45° to 90°, there was no significant difference in cannulation stability between the CB2 and MIK catheters. There was a potential tendency for MIK cannulation stability to be higher than CB2 for longitudinal openings in the range of 120° to 180° and lateral openings in the range of 45° to 90°, but there was no significant difference.
format Online
Article
Text
id pubmed-8677367
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-86773672021-12-17 Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring Lu, DongDong Chai, Wenshu Gao, Xue Yan, Xue J Healthc Eng Research Article We present in this paper an in-depth study and analysis of bronchiectasis haemoptysis by multirow CT tomography and a multifaceted treatment and analysis of the interventions monitored by the scan. Although coronary CT is of great clinical value in the diagnosis and monitoring of coronary artery disease, the potential radiation damage caused by coronary CT should not be underestimated because CT imaging is based on X-rays and the actual effective dose is 5–30 mSv, which is reported in the literature to be high when using conventional imaging modalities for coronary CT. Although there is no direct evidence of a definite causal relationship between X-ray exposure during CT examinations and tumorigenesis, theoretically, even small doses of radiation exposure may pose some potential health risk. Therefore, in clinical practice, coronary CT examinations should be performed in strict compliance with the radiation protection rule “as low as reasonably achievable” (ALARA) recognized by the radiation industry. For longitudinal openings in the range of 0° to 59° and transverse openings in the range of 0° to 44°, the CB2 catheter is significantly more stable than the MIK catheter, and for longitudinal openings in the range of 60° to 119° and transverse openings in the range of 0° to 44°, the CB2 catheter is more stable than the MIK catheter. For longitudinal openings from 0° to 120° and lateral openings from 45° to 90°, there was no significant difference in cannulation stability between the CB2 and MIK catheters. There was a potential tendency for MIK cannulation stability to be higher than CB2 for longitudinal openings in the range of 120° to 180° and lateral openings in the range of 45° to 90°, but there was no significant difference. Hindawi 2021-12-09 /pmc/articles/PMC8677367/ /pubmed/34925743 http://dx.doi.org/10.1155/2021/9116765 Text en Copyright © 2021 DongDong Lu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lu, DongDong
Chai, Wenshu
Gao, Xue
Yan, Xue
Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring
title Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring
title_full Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring
title_fullStr Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring
title_full_unstemmed Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring
title_short Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring
title_sort interventional treatment of bronchiectasis macrosomia based on multirow ct tomography monitoring
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8677367/
https://www.ncbi.nlm.nih.gov/pubmed/34925743
http://dx.doi.org/10.1155/2021/9116765
work_keys_str_mv AT ludongdong interventionaltreatmentofbronchiectasismacrosomiabasedonmultirowcttomographymonitoring
AT chaiwenshu interventionaltreatmentofbronchiectasismacrosomiabasedonmultirowcttomographymonitoring
AT gaoxue interventionaltreatmentofbronchiectasismacrosomiabasedonmultirowcttomographymonitoring
AT yanxue interventionaltreatmentofbronchiectasismacrosomiabasedonmultirowcttomographymonitoring