Cargando…

Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique

The lateral geniculate nucleus (LGN) is a small, inhomogeneous structure that relays major sensory inputs from the retina to the visual cortex. LGN morphology has been intensively studied due to various retinal diseases, as well as in the context of normal brain development. However, many of the met...

Descripción completa

Detalles Bibliográficos
Autores principales: Lipin, Mikhail, Bennett, Jean, Ying, Gui-Shuang, Yu, Yinxi, Ashtari, Manzar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8677828/
https://www.ncbi.nlm.nih.gov/pubmed/34924983
http://dx.doi.org/10.3389/fncom.2021.708866
_version_ 1784616224547667968
author Lipin, Mikhail
Bennett, Jean
Ying, Gui-Shuang
Yu, Yinxi
Ashtari, Manzar
author_facet Lipin, Mikhail
Bennett, Jean
Ying, Gui-Shuang
Yu, Yinxi
Ashtari, Manzar
author_sort Lipin, Mikhail
collection PubMed
description The lateral geniculate nucleus (LGN) is a small, inhomogeneous structure that relays major sensory inputs from the retina to the visual cortex. LGN morphology has been intensively studied due to various retinal diseases, as well as in the context of normal brain development. However, many of the methods used for LGN structural evaluations have not adequately addressed the challenges presented by the suboptimal routine MRI imaging of this structure. Here, we propose a novel method of edge enhancement that allows for high reliability and accuracy with regard to LGN morphometry, using routine 3D-MRI imaging protocols. This new algorithm is based on modeling a small brain structure as a polyhedron with its faces, edges, and vertices fitted with one plane, the intersection of two planes, and the intersection of three planes, respectively. This algorithm dramatically increases the contrast-to-noise ratio between the LGN and its surrounding structures as well as doubling the original spatial resolution. To show the algorithm efficacy, two raters (MA and ML) measured LGN volumes bilaterally in 19 subjects using the edge-enhanced LGN extracted areas from the 3D-T1 weighted images. The averages of the left and right LGN volumes from the two raters were 175 ± 8 and 174 ± 9 mm(3), respectively. The intra-class correlations between raters were 0.74 for the left and 0.81 for the right LGN volumes. The high contrast edge-enhanced LGN images presented here, from a 7-min routine 3T-MRI acquisition, is qualitatively comparable to previously reported LGN images that were acquired using a proton density sequence with 30–40 averages and 1.5-h of acquisition time. The proposed edge-enhancement algorithm is not limited only to the LGN, but can significantly improve the contrast-to-noise ratio of any small deep-seated gray matter brain structure that is prone to high-levels of noise and partial volume effects, and can also increase their morphometric accuracy and reliability. An immensely useful feature of the proposed algorithm is that it can be used retrospectively on noisy and low contrast 3D brain images previously acquired as part of any routine clinical MRI visit.
format Online
Article
Text
id pubmed-8677828
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86778282021-12-18 Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique Lipin, Mikhail Bennett, Jean Ying, Gui-Shuang Yu, Yinxi Ashtari, Manzar Front Comput Neurosci Neuroscience The lateral geniculate nucleus (LGN) is a small, inhomogeneous structure that relays major sensory inputs from the retina to the visual cortex. LGN morphology has been intensively studied due to various retinal diseases, as well as in the context of normal brain development. However, many of the methods used for LGN structural evaluations have not adequately addressed the challenges presented by the suboptimal routine MRI imaging of this structure. Here, we propose a novel method of edge enhancement that allows for high reliability and accuracy with regard to LGN morphometry, using routine 3D-MRI imaging protocols. This new algorithm is based on modeling a small brain structure as a polyhedron with its faces, edges, and vertices fitted with one plane, the intersection of two planes, and the intersection of three planes, respectively. This algorithm dramatically increases the contrast-to-noise ratio between the LGN and its surrounding structures as well as doubling the original spatial resolution. To show the algorithm efficacy, two raters (MA and ML) measured LGN volumes bilaterally in 19 subjects using the edge-enhanced LGN extracted areas from the 3D-T1 weighted images. The averages of the left and right LGN volumes from the two raters were 175 ± 8 and 174 ± 9 mm(3), respectively. The intra-class correlations between raters were 0.74 for the left and 0.81 for the right LGN volumes. The high contrast edge-enhanced LGN images presented here, from a 7-min routine 3T-MRI acquisition, is qualitatively comparable to previously reported LGN images that were acquired using a proton density sequence with 30–40 averages and 1.5-h of acquisition time. The proposed edge-enhancement algorithm is not limited only to the LGN, but can significantly improve the contrast-to-noise ratio of any small deep-seated gray matter brain structure that is prone to high-levels of noise and partial volume effects, and can also increase their morphometric accuracy and reliability. An immensely useful feature of the proposed algorithm is that it can be used retrospectively on noisy and low contrast 3D brain images previously acquired as part of any routine clinical MRI visit. Frontiers Media S.A. 2021-12-03 /pmc/articles/PMC8677828/ /pubmed/34924983 http://dx.doi.org/10.3389/fncom.2021.708866 Text en Copyright © 2021 Lipin, Bennett, Ying, Yu and Ashtari. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Lipin, Mikhail
Bennett, Jean
Ying, Gui-Shuang
Yu, Yinxi
Ashtari, Manzar
Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique
title Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique
title_full Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique
title_fullStr Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique
title_full_unstemmed Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique
title_short Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique
title_sort improving the quantification of the lateral geniculate nucleus in magnetic resonance imaging using a novel 3d-edge enhancement technique
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8677828/
https://www.ncbi.nlm.nih.gov/pubmed/34924983
http://dx.doi.org/10.3389/fncom.2021.708866
work_keys_str_mv AT lipinmikhail improvingthequantificationofthelateralgeniculatenucleusinmagneticresonanceimagingusinganovel3dedgeenhancementtechnique
AT bennettjean improvingthequantificationofthelateralgeniculatenucleusinmagneticresonanceimagingusinganovel3dedgeenhancementtechnique
AT yingguishuang improvingthequantificationofthelateralgeniculatenucleusinmagneticresonanceimagingusinganovel3dedgeenhancementtechnique
AT yuyinxi improvingthequantificationofthelateralgeniculatenucleusinmagneticresonanceimagingusinganovel3dedgeenhancementtechnique
AT ashtarimanzar improvingthequantificationofthelateralgeniculatenucleusinmagneticresonanceimagingusinganovel3dedgeenhancementtechnique