Cargando…

Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit

Although many whole-cell biosensors (WCBs) for the detection of Cd(2+) have been developed over the years, most lack sensitivity and specificity. In this paper, we developed a Cd(2+) WCB with a negative feedback amplifier in P. putida KT2440. Based on the slope of the linear detection curve as a mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Guangbao, Hu, Shuting, Jia, Xiaoqiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8678453/
https://www.ncbi.nlm.nih.gov/pubmed/34926437
http://dx.doi.org/10.3389/fbioe.2021.799781
_version_ 1784616308401242112
author Zhang, Guangbao
Hu, Shuting
Jia, Xiaoqiang
author_facet Zhang, Guangbao
Hu, Shuting
Jia, Xiaoqiang
author_sort Zhang, Guangbao
collection PubMed
description Although many whole-cell biosensors (WCBs) for the detection of Cd(2+) have been developed over the years, most lack sensitivity and specificity. In this paper, we developed a Cd(2+) WCB with a negative feedback amplifier in P. putida KT2440. Based on the slope of the linear detection curve as a measure of sensitivity, WCB with negative feedback amplifier greatly increased the output signal of the reporter mCherry, resulting in 33% greater sensitivity than in an equivalent WCB without the negative feedback circuit. Moreover, WCB with negative feedback amplifier exhibited increased Cd(2+) tolerance and a lower detection limit of 0.1 nM, a remarkable 400-fold improvement compared to the WCB without the negative feedback circuit, which is significantly below the World Health Organization standard of 27 nM (0.003 mg/L) for cadmium in drinking water. Due to the superior amplification of the output signal, WCB with negative feedback amplifier can provide a detectable signal in a much shorter time, and a fast response is highly preferable for real field applications. In addition, the WCB with negative feedback amplifier showed an unusually high specificity for Cd(2+) compared to other metal ions, giving signals with other metals that were between 17.6 and 41.4 times weaker than with Cd(2+). In summary, the negative feedback amplifier WCB designed in this work meets the requirements of Cd(2+) detection with very high sensitivity and specificity, which also demonstrates that genetic negative feedback amplifiers are excellent tools for improving the performance of WCBs.
format Online
Article
Text
id pubmed-8678453
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86784532021-12-18 Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit Zhang, Guangbao Hu, Shuting Jia, Xiaoqiang Front Bioeng Biotechnol Bioengineering and Biotechnology Although many whole-cell biosensors (WCBs) for the detection of Cd(2+) have been developed over the years, most lack sensitivity and specificity. In this paper, we developed a Cd(2+) WCB with a negative feedback amplifier in P. putida KT2440. Based on the slope of the linear detection curve as a measure of sensitivity, WCB with negative feedback amplifier greatly increased the output signal of the reporter mCherry, resulting in 33% greater sensitivity than in an equivalent WCB without the negative feedback circuit. Moreover, WCB with negative feedback amplifier exhibited increased Cd(2+) tolerance and a lower detection limit of 0.1 nM, a remarkable 400-fold improvement compared to the WCB without the negative feedback circuit, which is significantly below the World Health Organization standard of 27 nM (0.003 mg/L) for cadmium in drinking water. Due to the superior amplification of the output signal, WCB with negative feedback amplifier can provide a detectable signal in a much shorter time, and a fast response is highly preferable for real field applications. In addition, the WCB with negative feedback amplifier showed an unusually high specificity for Cd(2+) compared to other metal ions, giving signals with other metals that were between 17.6 and 41.4 times weaker than with Cd(2+). In summary, the negative feedback amplifier WCB designed in this work meets the requirements of Cd(2+) detection with very high sensitivity and specificity, which also demonstrates that genetic negative feedback amplifiers are excellent tools for improving the performance of WCBs. Frontiers Media S.A. 2021-12-03 /pmc/articles/PMC8678453/ /pubmed/34926437 http://dx.doi.org/10.3389/fbioe.2021.799781 Text en Copyright © 2021 Zhang, Hu and Jia. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Zhang, Guangbao
Hu, Shuting
Jia, Xiaoqiang
Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
title Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
title_full Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
title_fullStr Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
title_full_unstemmed Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
title_short Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
title_sort highly sensitive whole-cell biosensor for cadmium detection based on a negative feedback circuit
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8678453/
https://www.ncbi.nlm.nih.gov/pubmed/34926437
http://dx.doi.org/10.3389/fbioe.2021.799781
work_keys_str_mv AT zhangguangbao highlysensitivewholecellbiosensorforcadmiumdetectionbasedonanegativefeedbackcircuit
AT hushuting highlysensitivewholecellbiosensorforcadmiumdetectionbasedonanegativefeedbackcircuit
AT jiaxiaoqiang highlysensitivewholecellbiosensorforcadmiumdetectionbasedonanegativefeedbackcircuit