Cargando…

Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air

Aim: To compare the reliability of transtracheal ultrasound to confirm the endotracheal tube position with saline versus air inflated cuff. Methods: This was a prospective randomized cadaveric study. Four techniques were randomized: endotracheal tube in the trachea with air or saline inflated cuff,...

Descripción completa

Detalles Bibliográficos
Autores principales: Santinelli, Sarah, Audibert, Gérard, Nguyen Thi-Lambert, Phi Linh, Bouaziz, Hervé
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Exeley Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8678644/
https://www.ncbi.nlm.nih.gov/pubmed/34970440
http://dx.doi.org/10.15557/JoU.2021.0050
_version_ 1784616349691019264
author Santinelli, Sarah
Audibert, Gérard
Nguyen Thi-Lambert, Phi Linh
Bouaziz, Hervé
author_facet Santinelli, Sarah
Audibert, Gérard
Nguyen Thi-Lambert, Phi Linh
Bouaziz, Hervé
author_sort Santinelli, Sarah
collection PubMed
description Aim: To compare the reliability of transtracheal ultrasound to confirm the endotracheal tube position with saline versus air inflated cuff. Methods: This was a prospective randomized cadaveric study. Four techniques were randomized: endotracheal tube in the trachea with air or saline inflated cuff, and endotracheal tube in the esophagus with air or saline inflated cuff. The investigator used the Mcgrath to randomly place the endotracheal tube in the trachea or in the esophagus with saline or air inflated cuff. During the first series of measurements, nine residents performed transtracheal ultrasound with linear transducer placed transversely at the suprasternal notch. They were recorded with a cut off fixed to 30 seconds, and a questionnaire was completed by the residents after each transtracheal ultrasound in order to report where the endotracheal tube is positioned according to them. The second series followed the same protocol and included three residents who had participated in the first series. The primary outcome was the success rate in determining the position of the endotracheal tube. Results: In the first series, the success rate was 46.5%. In the second series, the success rate was 72.9%. There was no significant difference between cuff inflated with saline and air (p = 1.00). The overall mean time required was 20.6 s (95% CI 13.0–28.2 s). Based on an empirical data set, transtracheal ultrasound had a sensitivity of 62.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 26.08%. Conclusion: This investigation shows that regardless of the contents of the endotracheal tube cuff, the use of transtracheal ultrasound to confirm the position of endotracheal tube reports disappointing results.
format Online
Article
Text
id pubmed-8678644
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Exeley Inc.
record_format MEDLINE/PubMed
spelling pubmed-86786442021-12-29 Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air Santinelli, Sarah Audibert, Gérard Nguyen Thi-Lambert, Phi Linh Bouaziz, Hervé J Ultrason Medicine Aim: To compare the reliability of transtracheal ultrasound to confirm the endotracheal tube position with saline versus air inflated cuff. Methods: This was a prospective randomized cadaveric study. Four techniques were randomized: endotracheal tube in the trachea with air or saline inflated cuff, and endotracheal tube in the esophagus with air or saline inflated cuff. The investigator used the Mcgrath to randomly place the endotracheal tube in the trachea or in the esophagus with saline or air inflated cuff. During the first series of measurements, nine residents performed transtracheal ultrasound with linear transducer placed transversely at the suprasternal notch. They were recorded with a cut off fixed to 30 seconds, and a questionnaire was completed by the residents after each transtracheal ultrasound in order to report where the endotracheal tube is positioned according to them. The second series followed the same protocol and included three residents who had participated in the first series. The primary outcome was the success rate in determining the position of the endotracheal tube. Results: In the first series, the success rate was 46.5%. In the second series, the success rate was 72.9%. There was no significant difference between cuff inflated with saline and air (p = 1.00). The overall mean time required was 20.6 s (95% CI 13.0–28.2 s). Based on an empirical data set, transtracheal ultrasound had a sensitivity of 62.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 26.08%. Conclusion: This investigation shows that regardless of the contents of the endotracheal tube cuff, the use of transtracheal ultrasound to confirm the position of endotracheal tube reports disappointing results. Exeley Inc. 2021-11-29 2021-12-15 /pmc/articles/PMC8678644/ /pubmed/34970440 http://dx.doi.org/10.15557/JoU.2021.0050 Text en © Polish Ultrasound Society. Published by Medical Communications Sp. z o.o. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article licensed under the Creative Commons CC BY-NC-ND 4.0 license. https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Medicine
Santinelli, Sarah
Audibert, Gérard
Nguyen Thi-Lambert, Phi Linh
Bouaziz, Hervé
Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
title Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
title_full Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
title_fullStr Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
title_full_unstemmed Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
title_short Comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
title_sort comparative study of the reliability of ultrasound to confirm the position of endotracheal tube with cuff inflated with saline versus air
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8678644/
https://www.ncbi.nlm.nih.gov/pubmed/34970440
http://dx.doi.org/10.15557/JoU.2021.0050
work_keys_str_mv AT santinellisarah comparativestudyofthereliabilityofultrasoundtoconfirmthepositionofendotrachealtubewithcuffinflatedwithsalineversusair
AT audibertgerard comparativestudyofthereliabilityofultrasoundtoconfirmthepositionofendotrachealtubewithcuffinflatedwithsalineversusair
AT nguyenthilambertphilinh comparativestudyofthereliabilityofultrasoundtoconfirmthepositionofendotrachealtubewithcuffinflatedwithsalineversusair
AT bouazizherve comparativestudyofthereliabilityofultrasoundtoconfirmthepositionofendotrachealtubewithcuffinflatedwithsalineversusair