Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation

Actigraphy has been used to detect agitation in persons with dementia, although this technology must be worn by participants. Another promising sensing methodology is passive infrared (PIR) motion, which provides continuous, low-cost, and unobtrusive data, and may also improve the detection of agita...

Descripción completa

Detalles Bibliográficos
Autores principales: Au-Yeung, Wan-Tai, Miller, Lyndsey, Beattie, Zachary, Kaye, Jeffrey
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8681928/
http://dx.doi.org/10.1093/geroni/igab046.3422
_version_ 1784617093117771776
author Au-Yeung, Wan-Tai
Miller, Lyndsey
Beattie, Zachary
Kaye, Jeffrey
author_facet Au-Yeung, Wan-Tai
Miller, Lyndsey
Beattie, Zachary
Kaye, Jeffrey
author_sort Au-Yeung, Wan-Tai
collection PubMed
description Actigraphy has been used to detect agitation in persons with dementia, although this technology must be worn by participants. Another promising sensing methodology is passive infrared (PIR) motion, which provides continuous, low-cost, and unobtrusive data, and may also improve the detection of agitated periods. Using data from the MODERATE (Monitoring Dementia-Related Agitation Using Technology Evaluation) study, we compared the predictive value of detecting agitation in a male participant, who was 64 years old with Alzheimer’s disease (AD), living in a memory care unit, and monitored with actigraphy on his wrist and four PIR motion sensors within his living quarters. The participant’s medical record indicated that he experienced agitation during 17 nights over 96 consecutive days. 929,037 data points were captured for analysis. From each night, the features extracted from the actigraphy wearable included total and standard deviation of activity counts, activity counts in the most and the least active hours, and median activity counts in one hour. Features extracted from the PIR motion sensors included dwell durations in the areas around bed, sofa, front door and bathroom, and the number of transitions between these areas. Using logistic regression to predict agitated periods, comparable classification performances were achieved using these two sets of features (AUC = 0.74 for wearable and AUC = 0.71 for PIR motion sensors). When these two sets of features were combined, the classification performance showed notable improvement (AUC = 0.83). This study points to the value of utilizing PIR motion sensors for detecting dementia-related agitation.
format Online
Article
Text
id pubmed-8681928
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-86819282021-12-20 Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation Au-Yeung, Wan-Tai Miller, Lyndsey Beattie, Zachary Kaye, Jeffrey Innov Aging Abstracts Actigraphy has been used to detect agitation in persons with dementia, although this technology must be worn by participants. Another promising sensing methodology is passive infrared (PIR) motion, which provides continuous, low-cost, and unobtrusive data, and may also improve the detection of agitated periods. Using data from the MODERATE (Monitoring Dementia-Related Agitation Using Technology Evaluation) study, we compared the predictive value of detecting agitation in a male participant, who was 64 years old with Alzheimer’s disease (AD), living in a memory care unit, and monitored with actigraphy on his wrist and four PIR motion sensors within his living quarters. The participant’s medical record indicated that he experienced agitation during 17 nights over 96 consecutive days. 929,037 data points were captured for analysis. From each night, the features extracted from the actigraphy wearable included total and standard deviation of activity counts, activity counts in the most and the least active hours, and median activity counts in one hour. Features extracted from the PIR motion sensors included dwell durations in the areas around bed, sofa, front door and bathroom, and the number of transitions between these areas. Using logistic regression to predict agitated periods, comparable classification performances were achieved using these two sets of features (AUC = 0.74 for wearable and AUC = 0.71 for PIR motion sensors). When these two sets of features were combined, the classification performance showed notable improvement (AUC = 0.83). This study points to the value of utilizing PIR motion sensors for detecting dementia-related agitation. Oxford University Press 2021-12-17 /pmc/articles/PMC8681928/ http://dx.doi.org/10.1093/geroni/igab046.3422 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of The Gerontological Society of America. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Abstracts
Au-Yeung, Wan-Tai
Miller, Lyndsey
Beattie, Zachary
Kaye, Jeffrey
Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation
title Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation
title_full Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation
title_fullStr Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation
title_full_unstemmed Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation
title_short Passive Infrared Motion Sensors Improved the Detection Accuracy of Nocturnal Agitation
title_sort passive infrared motion sensors improved the detection accuracy of nocturnal agitation
topic Abstracts
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8681928/
http://dx.doi.org/10.1093/geroni/igab046.3422
work_keys_str_mv AT auyeungwantai passiveinfraredmotionsensorsimprovedthedetectionaccuracyofnocturnalagitation
AT millerlyndsey passiveinfraredmotionsensorsimprovedthedetectionaccuracyofnocturnalagitation
AT beattiezachary passiveinfraredmotionsensorsimprovedthedetectionaccuracyofnocturnalagitation
AT kayejeffrey passiveinfraredmotionsensorsimprovedthedetectionaccuracyofnocturnalagitation