Cargando…

Analytical characterization of the SARS-CoV-2 EURM-017 reference material

BACKGROUND: Current serological methods for SARS-CoV-2 lack adequate standardization to a universal standard reference material. Standardization will allow comparison of results across various lab-developed and commercial assays and publications. SARS-CoV-2 EURM-017 is human sera reference material...

Descripción completa

Detalles Bibliográficos
Autores principales: Freeman, James, Olson, Kalen, Conklin, Justin, Shalhoub, Victoria, Johnson, Bryan A., Bopp, Nathen E., Fernandez, Diana, Menachery, Vineet D., Aguilar, Patricia V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Canadian Society of Clinical Chemists. Published by Elsevier Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8684092/
https://www.ncbi.nlm.nih.gov/pubmed/34933006
http://dx.doi.org/10.1016/j.clinbiochem.2021.12.009
Descripción
Sumario:BACKGROUND: Current serological methods for SARS-CoV-2 lack adequate standardization to a universal standard reference material. Standardization will allow comparison of results across various lab-developed and commercial assays and publications. SARS-CoV-2 EURM-017 is human sera reference material containing antibodies directed against SARS-CoV-2 proteins, S1/S2 (full-length spike [S]), S1 receptor-binding domain (S1 RBD), S1, S2, and nucleocapsid (N) protein. The goal of this study was to characterize five antigen-specific serum fractions in EURM-017 for standardization of serology assays. METHODS: Five antigen-specific serum fractions were affinity purified, quantified, and PRNT(50) titers compared. Standardization methods were established for two anti-S1 RBD (IgG and Total Ig) and one N protein assay. For the anti-S1 RBD assays, standardization involved determining assay index values for serial dilutions of S1-RBD anti-sera. Index values for the anti-S1 RBD IgG assay and PRNT(50) titers were determined for 44 symptomatic COVID-19 patient sera. The index values were converted to EURM-017 ug/mL. RESULTS: Anti-sera protein content was as follows: S1 (17.7 µg/mL), S1 RBD (17.4 µg/mL), S1/S2 (full-length S) (34.1 µg/mL), S2 (29.7 µg/mL), and N protein (72.5 µg/mL). S1 anti-serum had the highest neutralization activity. A standardization method for S1 RBD anti-serum and an anti-S1 RBD IgG assay yielded the linear equation (y = 0.75x−0.10; y = index, x=µg/mL anti-serum). Patient sample index values for the S1-RBD IgG assay correlated well with PRNT(50) titers (Pearson r = 0.84). Using the equation above, patient index values were converted to standardized µg/mL. CONCLUSIONS: Standardization of different lab-developed and commercial assays to EURM-017 antigen-specific anti-sera will allow comparison of results across studies globally due to traceability to a single standard reference material.