Cargando…

Utility of Ultrasonographic Assessment of Distal Femoral Arterial Flow during Minimally Invasive Valve Surgery

Purpose: To evaluate the utility of ultrasonographic assessment of blood flow to the lower limb below the cannulation site in minimally invasive cardiac surgery (MICS). Methods: Twenty-two patients who underwent ultrasonographic assessment in MICS were reviewed retrospectively. In all patients, the...

Descripción completa

Detalles Bibliográficos
Autores principales: Hosono, Mitsuharu, Yasumoto, Hiroshi, Kuwauchi, Shintaro, Mitsunaga, Yoshino, Kanemoto, Shinya, Minato, Naoki, Kawazoe, Kohei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8684838/
https://www.ncbi.nlm.nih.gov/pubmed/34092724
http://dx.doi.org/10.5761/atcs.oa.21-00047
Descripción
Sumario:Purpose: To evaluate the utility of ultrasonographic assessment of blood flow to the lower limb below the cannulation site in minimally invasive cardiac surgery (MICS). Methods: Twenty-two patients who underwent ultrasonographic assessment in MICS were reviewed retrospectively. In all patients, the right femoral artery was used for arterial cannulation. Ultrasonographic assessment was performed using a 15-MHz ultrasonography small probe, and regional oxygen saturation was monitored by near-infrared spectroscopy (NIRS). Results: The mean flow velocity at the distal side of the cannulation site was 46.2 ± 25.4 cm/s. In six patients, a >40% decreased from baseline regional oxygen saturation was observed. In five of the six patients, the flow velocity was very slow, and spontaneous echo contrast was also observed in three cases. Their regional oxygen saturation was improved rapidly after distal leg perfusion. In the remaining case, the flow velocity was not decreased. In another one case, the stenosis at the cannulation site was detected after decannulation and repaired immediately. No limb ischemic complications were observed in this series. Conclusion: Ultrasonographic assessment combined with the NIRS monitoring is useful to prevent lower limb ischemic complications after femoral arterial cannulation in MICS.