Cargando…

The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal

Background: Superior capsular reconstruction (SCR) has shown good results in the management of irreparable rotator cuff tears due to the depressive effect on the humeral head, but it is a technically demanding and expensive procedure. Purpose: We hypothesized that an intra-articular neoligament that...

Descripción completa

Detalles Bibliográficos
Autores principales: Luciani, Pierfrancesco, Farinelli, Luca, De Berardinis, Luca, Gigante, Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8685248/
https://www.ncbi.nlm.nih.gov/pubmed/34938765
http://dx.doi.org/10.3389/fsurg.2021.624100
_version_ 1784617793158643712
author Luciani, Pierfrancesco
Farinelli, Luca
De Berardinis, Luca
Gigante, Antonio
author_facet Luciani, Pierfrancesco
Farinelli, Luca
De Berardinis, Luca
Gigante, Antonio
author_sort Luciani, Pierfrancesco
collection PubMed
description Background: Superior capsular reconstruction (SCR) has shown good results in the management of irreparable rotator cuff tears due to the depressive effect on the humeral head, but it is a technically demanding and expensive procedure. Purpose: We hypothesized that an intra-articular neoligament that prevents the superior translation of the humeral head could give similar results in terms of the superior translation of humerus (STH) and range of motion (ROM). Study Design: To compare our proposed technique and the SCR, we conducted a biomechanical study on 10 porcine shoulders in a custom shoulder testing system. Methods: STH and total rotational ROM were quantified in the following four scenarios: (1) when the rotator cuff was intact, (2) after cutting the supraspinatus tendon, (3) after the reconstruction of the superior capsule by long head of the biceps tendon (LHB), and (4) after an arthroscopic intra-articular stabilization by an intra-articular graft. Our proposed technique provides the creation of a humeral and glenoid tunnel, the passage of a graft through these tunnels under arthroscopic guidance, and the graft fixation in the two tunnels. We analyzed the STH and total ROM in each scenario. Results: With respect to the STH, we reported that the present proposed technique is characterized by a significant reduction of superior translation at 0 and 45° compared to scenario 2. In addition, the comparison between our proposed technique and SCR showed a significant difference of the STH at 0° of abduction. Total rotational ROMs of the two tenchinques were similar to scenario 2. Therefore, the use of an intra-articular ligament that prevents the STH can restore shoulder stability in irreparable rotator cuff injuries at both 0 and 45° of glenohumeral abduction without apparently limiting the total rotational ROM. Conclusion: Our proposed technique could be an important treatment option in irreparable rotator cuff tears, especially in patients under 65 years in whom reverse shoulder arthroplasty (RSA) has shown poor results and many complications.
format Online
Article
Text
id pubmed-8685248
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86852482021-12-21 The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal Luciani, Pierfrancesco Farinelli, Luca De Berardinis, Luca Gigante, Antonio Front Surg Surgery Background: Superior capsular reconstruction (SCR) has shown good results in the management of irreparable rotator cuff tears due to the depressive effect on the humeral head, but it is a technically demanding and expensive procedure. Purpose: We hypothesized that an intra-articular neoligament that prevents the superior translation of the humeral head could give similar results in terms of the superior translation of humerus (STH) and range of motion (ROM). Study Design: To compare our proposed technique and the SCR, we conducted a biomechanical study on 10 porcine shoulders in a custom shoulder testing system. Methods: STH and total rotational ROM were quantified in the following four scenarios: (1) when the rotator cuff was intact, (2) after cutting the supraspinatus tendon, (3) after the reconstruction of the superior capsule by long head of the biceps tendon (LHB), and (4) after an arthroscopic intra-articular stabilization by an intra-articular graft. Our proposed technique provides the creation of a humeral and glenoid tunnel, the passage of a graft through these tunnels under arthroscopic guidance, and the graft fixation in the two tunnels. We analyzed the STH and total ROM in each scenario. Results: With respect to the STH, we reported that the present proposed technique is characterized by a significant reduction of superior translation at 0 and 45° compared to scenario 2. In addition, the comparison between our proposed technique and SCR showed a significant difference of the STH at 0° of abduction. Total rotational ROMs of the two tenchinques were similar to scenario 2. Therefore, the use of an intra-articular ligament that prevents the STH can restore shoulder stability in irreparable rotator cuff injuries at both 0 and 45° of glenohumeral abduction without apparently limiting the total rotational ROM. Conclusion: Our proposed technique could be an important treatment option in irreparable rotator cuff tears, especially in patients under 65 years in whom reverse shoulder arthroplasty (RSA) has shown poor results and many complications. Frontiers Media S.A. 2021-12-06 /pmc/articles/PMC8685248/ /pubmed/34938765 http://dx.doi.org/10.3389/fsurg.2021.624100 Text en Copyright © 2021 Luciani, Farinelli, De Berardinis and Gigante. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Luciani, Pierfrancesco
Farinelli, Luca
De Berardinis, Luca
Gigante, Antonio
The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal
title The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal
title_full The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal
title_fullStr The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal
title_full_unstemmed The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal
title_short The Arthroscopic Intra-Articular Stabilization of the Shoulder for Irreparable Rotator Cuff Tear: A New Technique Proposal
title_sort arthroscopic intra-articular stabilization of the shoulder for irreparable rotator cuff tear: a new technique proposal
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8685248/
https://www.ncbi.nlm.nih.gov/pubmed/34938765
http://dx.doi.org/10.3389/fsurg.2021.624100
work_keys_str_mv AT lucianipierfrancesco thearthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT farinelliluca thearthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT deberardinisluca thearthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT giganteantonio thearthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT lucianipierfrancesco arthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT farinelliluca arthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT deberardinisluca arthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal
AT giganteantonio arthroscopicintraarticularstabilizationoftheshoulderforirreparablerotatorcufftearanewtechniqueproposal