Cargando…

The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index

BACKGROUND: Our goal is to investigate the use of the oxygen reserve index (ORi) to detect hypoxemia and its relation with parameters such as; peripheral oxygen saturation, perfusion index (PI), and pleth variability index (PVI) during one-lung ventilation (OLV). METHODS: Fifty patients undergoing g...

Descripción completa

Detalles Bibliográficos
Autores principales: Sagiroglu, Gonul, Baysal, Ayse, Karamustafaoglu, Yekta Altemur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8685494/
https://www.ncbi.nlm.nih.gov/pubmed/34930139
http://dx.doi.org/10.1186/s12871-021-01539-8
_version_ 1784617843708395520
author Sagiroglu, Gonul
Baysal, Ayse
Karamustafaoglu, Yekta Altemur
author_facet Sagiroglu, Gonul
Baysal, Ayse
Karamustafaoglu, Yekta Altemur
author_sort Sagiroglu, Gonul
collection PubMed
description BACKGROUND: Our goal is to investigate the use of the oxygen reserve index (ORi) to detect hypoxemia and its relation with parameters such as; peripheral oxygen saturation, perfusion index (PI), and pleth variability index (PVI) during one-lung ventilation (OLV). METHODS: Fifty patients undergoing general anesthesia and OLV for elective thoracic surgeries were enrolled in an observational cohort study in a tertiary care teaching hospital. All patients required OLV after a left-sided double-lumen tube insertion during intubation. The definition of hypoxemia during OLV is a peripheral oxygen saturation (SpO2) value of less than 95%, while the inspired oxygen fraction (FiO2) is higher than 50% on a pulse oximetry device. ORi, pulse oximetry, PI, and PVI values were measured continuously. Sensitivity, specificity, positive and negative predictive values, likelihood ratios, and accuracy were calculated for ORi values equal to zero in different time points during surgery to predict hypoxemia. At Clinicaltrials.gov registry, the Registration ID is NCT05050552. RESULTS: Hypoxemia was observed in 19 patients (38%). The accuracy for predicting hypoxemia during anesthesia induction at ORi value equals zero at 5 min after intubation in the supine position (DS5) showed a sensitivity of 92.3% (95% CI 84.9–99.6), specificity of 81.1% (95% CI 70.2–91.9), and an accuracy of 84.0% (95% CI 73.8–94.2). For predicting hypoxemia, ORi equals zero show good sensitivity, specificity, and statistical accuracy values for time points of DS5 until OLV30 where the sensitivity of 43.8%, specificity of 64%, and an accuracy of 56.1% were recorded. ORi and SpO2 correlation was found at DS5, 5 min after lateral position with two-lung ventilation (DL5) and at 10 min after OLV (OLV10) (p = 0.044, p = 0.039, p = 0.011, respectively). Time-dependent correlations also showed that; at a time point of DS5, ORi has a significant negative correlation with PI whereas, no correlations with PVI were noted. CONCLUSIONS: During the use of OLV for thoracic surgeries, from 5 min after intubation (DS5) up to 30 min after the start of OLV, ORi provides valuable information in predicting hypoxemia defined as SpO2 less than 95% on pulse oximeter at FiO2 higher than 50%.
format Online
Article
Text
id pubmed-8685494
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86854942021-12-20 The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index Sagiroglu, Gonul Baysal, Ayse Karamustafaoglu, Yekta Altemur BMC Anesthesiol Research BACKGROUND: Our goal is to investigate the use of the oxygen reserve index (ORi) to detect hypoxemia and its relation with parameters such as; peripheral oxygen saturation, perfusion index (PI), and pleth variability index (PVI) during one-lung ventilation (OLV). METHODS: Fifty patients undergoing general anesthesia and OLV for elective thoracic surgeries were enrolled in an observational cohort study in a tertiary care teaching hospital. All patients required OLV after a left-sided double-lumen tube insertion during intubation. The definition of hypoxemia during OLV is a peripheral oxygen saturation (SpO2) value of less than 95%, while the inspired oxygen fraction (FiO2) is higher than 50% on a pulse oximetry device. ORi, pulse oximetry, PI, and PVI values were measured continuously. Sensitivity, specificity, positive and negative predictive values, likelihood ratios, and accuracy were calculated for ORi values equal to zero in different time points during surgery to predict hypoxemia. At Clinicaltrials.gov registry, the Registration ID is NCT05050552. RESULTS: Hypoxemia was observed in 19 patients (38%). The accuracy for predicting hypoxemia during anesthesia induction at ORi value equals zero at 5 min after intubation in the supine position (DS5) showed a sensitivity of 92.3% (95% CI 84.9–99.6), specificity of 81.1% (95% CI 70.2–91.9), and an accuracy of 84.0% (95% CI 73.8–94.2). For predicting hypoxemia, ORi equals zero show good sensitivity, specificity, and statistical accuracy values for time points of DS5 until OLV30 where the sensitivity of 43.8%, specificity of 64%, and an accuracy of 56.1% were recorded. ORi and SpO2 correlation was found at DS5, 5 min after lateral position with two-lung ventilation (DL5) and at 10 min after OLV (OLV10) (p = 0.044, p = 0.039, p = 0.011, respectively). Time-dependent correlations also showed that; at a time point of DS5, ORi has a significant negative correlation with PI whereas, no correlations with PVI were noted. CONCLUSIONS: During the use of OLV for thoracic surgeries, from 5 min after intubation (DS5) up to 30 min after the start of OLV, ORi provides valuable information in predicting hypoxemia defined as SpO2 less than 95% on pulse oximeter at FiO2 higher than 50%. BioMed Central 2021-12-20 /pmc/articles/PMC8685494/ /pubmed/34930139 http://dx.doi.org/10.1186/s12871-021-01539-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Sagiroglu, Gonul
Baysal, Ayse
Karamustafaoglu, Yekta Altemur
The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
title The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
title_full The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
title_fullStr The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
title_full_unstemmed The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
title_short The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
title_sort use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8685494/
https://www.ncbi.nlm.nih.gov/pubmed/34930139
http://dx.doi.org/10.1186/s12871-021-01539-8
work_keys_str_mv AT sagiroglugonul theuseofoxygenreserveindexinonelungventilationanditsimpactonperipheraloxygensaturationperfusionindexandplethvariabilityindex
AT baysalayse theuseofoxygenreserveindexinonelungventilationanditsimpactonperipheraloxygensaturationperfusionindexandplethvariabilityindex
AT karamustafaogluyektaaltemur theuseofoxygenreserveindexinonelungventilationanditsimpactonperipheraloxygensaturationperfusionindexandplethvariabilityindex
AT sagiroglugonul useofoxygenreserveindexinonelungventilationanditsimpactonperipheraloxygensaturationperfusionindexandplethvariabilityindex
AT baysalayse useofoxygenreserveindexinonelungventilationanditsimpactonperipheraloxygensaturationperfusionindexandplethvariabilityindex
AT karamustafaogluyektaaltemur useofoxygenreserveindexinonelungventilationanditsimpactonperipheraloxygensaturationperfusionindexandplethvariabilityindex