Cargando…

Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals

BACKGROUND: The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) provides evidence-based criteria for peripherally inserted central catheter (PICC) use. Whether implementing MAGIC improves PICC appropriateness and reduces complications is unknown. METHODS: A quasiexperimental study d...

Descripción completa

Detalles Bibliográficos
Autores principales: Chopra, Vineet, O'Malley, Megan, Horowitz, Jennifer, Zhang, Qisu, McLaughlin, Elizabeth, Saint, Sanjay, Bernstein, Steven J, Flanders, Scott
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8685627/
https://www.ncbi.nlm.nih.gov/pubmed/33782091
http://dx.doi.org/10.1136/bmjqs-2021-013015
_version_ 1784617869556842496
author Chopra, Vineet
O'Malley, Megan
Horowitz, Jennifer
Zhang, Qisu
McLaughlin, Elizabeth
Saint, Sanjay
Bernstein, Steven J
Flanders, Scott
author_facet Chopra, Vineet
O'Malley, Megan
Horowitz, Jennifer
Zhang, Qisu
McLaughlin, Elizabeth
Saint, Sanjay
Bernstein, Steven J
Flanders, Scott
author_sort Chopra, Vineet
collection PubMed
description BACKGROUND: The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) provides evidence-based criteria for peripherally inserted central catheter (PICC) use. Whether implementing MAGIC improves PICC appropriateness and reduces complications is unknown. METHODS: A quasiexperimental study design to implement MAGIC in 52 Michigan hospitals was used. Data were collected from medical records by trained abstractors. Hospital performance on three appropriateness criteria was measured: short-term PICC use (≤5 days), use of multilumen PICCs and PICC placement in patients with chronic kidney disease. PICC appropriateness and device complications preintervention (January 2013 to December 2016) versus postintervention (January 2017 to January 2020) were compared. Change-point analysis was used to evaluate the effect of the intervention on device appropriateness. Logistic regression and Poisson models were fit to assess the association between appropriateness and complications (composite of catheter occlusion, venous thromboembolism (VTE) and central line-associated bloodstream infection (CLABSI)). RESULTS: Among 38 592 PICCs, median catheter dwell ranged from 8 to 56 days. During the preintervention period, the mean frequency of appropriate PICC use was 31.9% and the mean frequency of complications was 14.7%. Following the intervention, PICC appropriateness increased to 49.0% (absolute difference 17.1%, p<0.001) while complications decreased to 10.7% (absolute difference 4.0%, p=0.001). Compared with patients with inappropriate PICC placement, appropriate PICC use was associated with a significantly lower odds of complications (OR 0.29, 95% CI 0.25 to 0.34), including decreases in occlusion (OR 0.25, 95% CI 0.21 to 0.29), CLABSI (OR 0.61, 95% CI 0.46 to 0.81) and VTE (OR 0.40, 95% CI 0.33 to 0.47, all p<0.01). Patients with appropriate PICC placement had lower rate of complications than those with inappropriate PICC use (incidence rate ratio 0.987, 95% CI 0.98 to 0.99, p<0.001). CONCLUSIONS: Implementation of MAGIC in Michigan hospitals was associated with improved PICC appropriateness and fewer complications. These findings have important quality, safety and policy implications for hospitals, patients and payors.
format Online
Article
Text
id pubmed-8685627
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-86856272022-01-04 Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals Chopra, Vineet O'Malley, Megan Horowitz, Jennifer Zhang, Qisu McLaughlin, Elizabeth Saint, Sanjay Bernstein, Steven J Flanders, Scott BMJ Qual Saf Original Research BACKGROUND: The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) provides evidence-based criteria for peripherally inserted central catheter (PICC) use. Whether implementing MAGIC improves PICC appropriateness and reduces complications is unknown. METHODS: A quasiexperimental study design to implement MAGIC in 52 Michigan hospitals was used. Data were collected from medical records by trained abstractors. Hospital performance on three appropriateness criteria was measured: short-term PICC use (≤5 days), use of multilumen PICCs and PICC placement in patients with chronic kidney disease. PICC appropriateness and device complications preintervention (January 2013 to December 2016) versus postintervention (January 2017 to January 2020) were compared. Change-point analysis was used to evaluate the effect of the intervention on device appropriateness. Logistic regression and Poisson models were fit to assess the association between appropriateness and complications (composite of catheter occlusion, venous thromboembolism (VTE) and central line-associated bloodstream infection (CLABSI)). RESULTS: Among 38 592 PICCs, median catheter dwell ranged from 8 to 56 days. During the preintervention period, the mean frequency of appropriate PICC use was 31.9% and the mean frequency of complications was 14.7%. Following the intervention, PICC appropriateness increased to 49.0% (absolute difference 17.1%, p<0.001) while complications decreased to 10.7% (absolute difference 4.0%, p=0.001). Compared with patients with inappropriate PICC placement, appropriate PICC use was associated with a significantly lower odds of complications (OR 0.29, 95% CI 0.25 to 0.34), including decreases in occlusion (OR 0.25, 95% CI 0.21 to 0.29), CLABSI (OR 0.61, 95% CI 0.46 to 0.81) and VTE (OR 0.40, 95% CI 0.33 to 0.47, all p<0.01). Patients with appropriate PICC placement had lower rate of complications than those with inappropriate PICC use (incidence rate ratio 0.987, 95% CI 0.98 to 0.99, p<0.001). CONCLUSIONS: Implementation of MAGIC in Michigan hospitals was associated with improved PICC appropriateness and fewer complications. These findings have important quality, safety and policy implications for hospitals, patients and payors. BMJ Publishing Group 2022-01 2021-03-29 /pmc/articles/PMC8685627/ /pubmed/33782091 http://dx.doi.org/10.1136/bmjqs-2021-013015 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Original Research
Chopra, Vineet
O'Malley, Megan
Horowitz, Jennifer
Zhang, Qisu
McLaughlin, Elizabeth
Saint, Sanjay
Bernstein, Steven J
Flanders, Scott
Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals
title Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals
title_full Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals
title_fullStr Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals
title_full_unstemmed Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals
title_short Improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 Michigan hospitals
title_sort improving peripherally inserted central catheter appropriateness and reducing device-related complications: a quasiexperimental study in 52 michigan hospitals
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8685627/
https://www.ncbi.nlm.nih.gov/pubmed/33782091
http://dx.doi.org/10.1136/bmjqs-2021-013015
work_keys_str_mv AT chopravineet improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT omalleymegan improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT horowitzjennifer improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT zhangqisu improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT mclaughlinelizabeth improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT saintsanjay improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT bernsteinstevenj improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals
AT flandersscott improvingperipherallyinsertedcentralcatheterappropriatenessandreducingdevicerelatedcomplicationsaquasiexperimentalstudyin52michiganhospitals