Cargando…
Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study
OBJECTIVE: This study aimed to compare the two nickel–titanium (NiTi) instruments on root dentin thickness using cone-beam computed tomography (CBCT) and ability to remove the smear layer using scanning electron microscope (SEM). MATERIALS AND METHODS: The effect of two NiTi rotary instruments such...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8686943/ https://www.ncbi.nlm.nih.gov/pubmed/35018043 http://dx.doi.org/10.4103/jpbs.jpbs_346_21 |
_version_ | 1784618112163774464 |
---|---|
author | Reddy, Gangili Sparsha Kalaiselvam, Rajeswari Rajakumaran, Arasappan Kuzhanchinathan, Manigandan Sabarish, Ram Ganesh, Arathi |
author_facet | Reddy, Gangili Sparsha Kalaiselvam, Rajeswari Rajakumaran, Arasappan Kuzhanchinathan, Manigandan Sabarish, Ram Ganesh, Arathi |
author_sort | Reddy, Gangili Sparsha |
collection | PubMed |
description | OBJECTIVE: This study aimed to compare the two nickel–titanium (NiTi) instruments on root dentin thickness using cone-beam computed tomography (CBCT) and ability to remove the smear layer using scanning electron microscope (SEM). MATERIALS AND METHODS: The effect of two NiTi rotary instruments such as XP Endo shaper and ProTaper Gold (PTG) in retaining adequate dentin thickness and debridement (i.e., removal of smear layer) was evaluated in vitro using CBCT and SEM. After cleaning and shaping of the root canal with adequate irrigation, the effect of two NiTi instrument systems at 3 mm (apical), 6 mm (middle), and 9 mm (coronal) levels on buccal, lingual, mesial, and distal aspects in terms of amount of dentin removal and smear layer removal was evaluated. The data were analyzed using student's unpaired t-test with a significance of P ≤ 0.05. RESULTS: Both NiTi instrument systems had no statistically significant difference in amount of dentin removal at all three levels and on all four aspects. In smear layer removal, PTG had significantly better efficacy compared to XP Endo shaper at the coronal third of root canal. CONCLUSION: Instrumentation with XP Endo Shaper and PTG showed a similar amount of dentin removal. PTG has a significant effect on smear layer removal compared to XP Endo Shaper only at the coronal third of root canal. |
format | Online Article Text |
id | pubmed-8686943 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-86869432022-01-10 Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study Reddy, Gangili Sparsha Kalaiselvam, Rajeswari Rajakumaran, Arasappan Kuzhanchinathan, Manigandan Sabarish, Ram Ganesh, Arathi J Pharm Bioallied Sci Original Article OBJECTIVE: This study aimed to compare the two nickel–titanium (NiTi) instruments on root dentin thickness using cone-beam computed tomography (CBCT) and ability to remove the smear layer using scanning electron microscope (SEM). MATERIALS AND METHODS: The effect of two NiTi rotary instruments such as XP Endo shaper and ProTaper Gold (PTG) in retaining adequate dentin thickness and debridement (i.e., removal of smear layer) was evaluated in vitro using CBCT and SEM. After cleaning and shaping of the root canal with adequate irrigation, the effect of two NiTi instrument systems at 3 mm (apical), 6 mm (middle), and 9 mm (coronal) levels on buccal, lingual, mesial, and distal aspects in terms of amount of dentin removal and smear layer removal was evaluated. The data were analyzed using student's unpaired t-test with a significance of P ≤ 0.05. RESULTS: Both NiTi instrument systems had no statistically significant difference in amount of dentin removal at all three levels and on all four aspects. In smear layer removal, PTG had significantly better efficacy compared to XP Endo shaper at the coronal third of root canal. CONCLUSION: Instrumentation with XP Endo Shaper and PTG showed a similar amount of dentin removal. PTG has a significant effect on smear layer removal compared to XP Endo Shaper only at the coronal third of root canal. Wolters Kluwer - Medknow 2021-11 2021-11-10 /pmc/articles/PMC8686943/ /pubmed/35018043 http://dx.doi.org/10.4103/jpbs.jpbs_346_21 Text en Copyright: © 2021 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Reddy, Gangili Sparsha Kalaiselvam, Rajeswari Rajakumaran, Arasappan Kuzhanchinathan, Manigandan Sabarish, Ram Ganesh, Arathi Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study |
title | Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study |
title_full | Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study |
title_fullStr | Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study |
title_full_unstemmed | Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study |
title_short | Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments – An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study |
title_sort | evaluation of root dentin thickness and smear layer removal efficacy of two novel nickel titanium rotary instruments – an in vitro cone-beam computed tomography and scanning electron microscopy study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8686943/ https://www.ncbi.nlm.nih.gov/pubmed/35018043 http://dx.doi.org/10.4103/jpbs.jpbs_346_21 |
work_keys_str_mv | AT reddygangilisparsha evaluationofrootdentinthicknessandsmearlayerremovalefficacyoftwonovelnickeltitaniumrotaryinstrumentsaninvitroconebeamcomputedtomographyandscanningelectronmicroscopystudy AT kalaiselvamrajeswari evaluationofrootdentinthicknessandsmearlayerremovalefficacyoftwonovelnickeltitaniumrotaryinstrumentsaninvitroconebeamcomputedtomographyandscanningelectronmicroscopystudy AT rajakumaranarasappan evaluationofrootdentinthicknessandsmearlayerremovalefficacyoftwonovelnickeltitaniumrotaryinstrumentsaninvitroconebeamcomputedtomographyandscanningelectronmicroscopystudy AT kuzhanchinathanmanigandan evaluationofrootdentinthicknessandsmearlayerremovalefficacyoftwonovelnickeltitaniumrotaryinstrumentsaninvitroconebeamcomputedtomographyandscanningelectronmicroscopystudy AT sabarishram evaluationofrootdentinthicknessandsmearlayerremovalefficacyoftwonovelnickeltitaniumrotaryinstrumentsaninvitroconebeamcomputedtomographyandscanningelectronmicroscopystudy AT ganesharathi evaluationofrootdentinthicknessandsmearlayerremovalefficacyoftwonovelnickeltitaniumrotaryinstrumentsaninvitroconebeamcomputedtomographyandscanningelectronmicroscopystudy |