Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research

INTRODUCTION: External high-volume extraction (HVE) devices may offer a way to reduce any aerosol particulate generated. The aim of this study was to measure the particle count during dental aerosol-generating procedures and compare the results with when a HVE device is used. MATERIALS AND METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Alamri, Abeer Ayiad, Almutairi, Ayad Bulayd, Hawsah, Abeer Mohammed, Aljarullah, Atheer Hussain, Almeerabdullah, Yara Waleed, Alenezi, Maha Abdullah, Ahmed, Suhael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8687041/
https://www.ncbi.nlm.nih.gov/pubmed/35018049
http://dx.doi.org/10.4103/jpbs.jpbs_390_21
_version_ 1784618135837474816
author Alamri, Abeer Ayiad
Almutairi, Ayad Bulayd
Hawsah, Abeer Mohammed
Aljarullah, Atheer Hussain
Almeerabdullah, Yara Waleed
Alenezi, Maha Abdullah
Ahmed, Suhael
author_facet Alamri, Abeer Ayiad
Almutairi, Ayad Bulayd
Hawsah, Abeer Mohammed
Aljarullah, Atheer Hussain
Almeerabdullah, Yara Waleed
Alenezi, Maha Abdullah
Ahmed, Suhael
author_sort Alamri, Abeer Ayiad
collection PubMed
description INTRODUCTION: External high-volume extraction (HVE) devices may offer a way to reduce any aerosol particulate generated. The aim of this study was to measure the particle count during dental aerosol-generating procedures and compare the results with when a HVE device is used. MATERIALS AND METHODS: Design A comparative clinical study measuring the amount of PM1, PM2.5, and PM10 aerosol particulate with and without the use of an external HVE device was undertaken. Materials and methods in total, ten restorative procedures were monitored with an industrial Trotec PC220 particle counter. The intervention was an external HVE device. Main outcome methods the air sampler was placed at the average working distance of the clinicians involved in the study − 420 mm. RESULTS: In the present study, aerosol particulate was recorded at statistically significantly increased levels during dental procedures without an external HVE device versus with the device. Discussion The null hypothesis was rejected, in that significant differences were found between the results of the amount of aerosol particle count with and without a HVE device. CONCLUSION: If the results of the present study are repeated in an in vivo setting, an external high-volume suction device may potentially show a lower risk of transmission of viral particulate.
format Online
Article
Text
id pubmed-8687041
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-86870412022-01-10 Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research Alamri, Abeer Ayiad Almutairi, Ayad Bulayd Hawsah, Abeer Mohammed Aljarullah, Atheer Hussain Almeerabdullah, Yara Waleed Alenezi, Maha Abdullah Ahmed, Suhael J Pharm Bioallied Sci Original Article INTRODUCTION: External high-volume extraction (HVE) devices may offer a way to reduce any aerosol particulate generated. The aim of this study was to measure the particle count during dental aerosol-generating procedures and compare the results with when a HVE device is used. MATERIALS AND METHODS: Design A comparative clinical study measuring the amount of PM1, PM2.5, and PM10 aerosol particulate with and without the use of an external HVE device was undertaken. Materials and methods in total, ten restorative procedures were monitored with an industrial Trotec PC220 particle counter. The intervention was an external HVE device. Main outcome methods the air sampler was placed at the average working distance of the clinicians involved in the study − 420 mm. RESULTS: In the present study, aerosol particulate was recorded at statistically significantly increased levels during dental procedures without an external HVE device versus with the device. Discussion The null hypothesis was rejected, in that significant differences were found between the results of the amount of aerosol particle count with and without a HVE device. CONCLUSION: If the results of the present study are repeated in an in vivo setting, an external high-volume suction device may potentially show a lower risk of transmission of viral particulate. Wolters Kluwer - Medknow 2021-11 2021-11-10 /pmc/articles/PMC8687041/ /pubmed/35018049 http://dx.doi.org/10.4103/jpbs.jpbs_390_21 Text en Copyright: © 2021 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Alamri, Abeer Ayiad
Almutairi, Ayad Bulayd
Hawsah, Abeer Mohammed
Aljarullah, Atheer Hussain
Almeerabdullah, Yara Waleed
Alenezi, Maha Abdullah
Ahmed, Suhael
Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research
title Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research
title_full Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research
title_fullStr Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research
title_full_unstemmed Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research
title_short Evaluation of Reduction Protocols in Managing Aerosol Generation in Caries Management in COVID 19 in Riyadh: An Original Research
title_sort evaluation of reduction protocols in managing aerosol generation in caries management in covid 19 in riyadh: an original research
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8687041/
https://www.ncbi.nlm.nih.gov/pubmed/35018049
http://dx.doi.org/10.4103/jpbs.jpbs_390_21
work_keys_str_mv AT alamriabeerayiad evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch
AT almutairiayadbulayd evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch
AT hawsahabeermohammed evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch
AT aljarullahatheerhussain evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch
AT almeerabdullahyarawaleed evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch
AT alenezimahaabdullah evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch
AT ahmedsuhael evaluationofreductionprotocolsinmanagingaerosolgenerationincariesmanagementincovid19inriyadhanoriginalresearch