Cargando…

Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion

PURPOSE: To evaluate the biomechanics of simulated posterior cruciate ligament injuries (SimPCL) with and without internal brace suture tape augmentation (IBSTA) in cadaver knees. METHODS: A total of 20 cadaveric knees were used, all male, with an average age of 65 ± 18 years. Femoral tunnel isometr...

Descripción completa

Detalles Bibliográficos
Autores principales: Ostrander, Roger, Jordan, Steve, Konicek, John, Baldwin, William
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8689244/
https://www.ncbi.nlm.nih.gov/pubmed/34977635
http://dx.doi.org/10.1016/j.asmr.2021.08.008
_version_ 1784618512577200128
author Ostrander, Roger
Jordan, Steve
Konicek, John
Baldwin, William
author_facet Ostrander, Roger
Jordan, Steve
Konicek, John
Baldwin, William
author_sort Ostrander, Roger
collection PubMed
description PURPOSE: To evaluate the biomechanics of simulated posterior cruciate ligament injuries (SimPCL) with and without internal brace suture tape augmentation (IBSTA) in cadaver knees. METHODS: A total of 20 cadaveric knees were used, all male, with an average age of 65 ± 18 years. Femoral tunnel isometry was evaluated at the 1/11 o’clock and 2/10 o’clock femoral positions. SimPCL were created in 6 knees. IBSTA was performed, and load data were collected through knee range of motion. An additional 6 specimens were evaluated at the 1/11 femoral tunnel position, and load cell recordings were obtained at 10 different knee flexion angles. Cyclic displacement in 8 cadaver knees was assessed using an Instron machine. Load and displacement data were recorded. Testing was performed under 3 conditions for each specimen: intact PCL, SimPCL, and SimPCL/IBSTA using the 1/11 femoral tunnel position. RESULTS: There was no difference in isometry when comparing the 1/11 o’clock (7.1 ± 4.0 ft∗lb) femoral position and the 2/10 o’clock (7.6 ± 4.2 ft∗lb) position (P = .467). SimPCL/IBSTA suture tape tension gradually increased with progressive flexion to a peak at approximately 120° of knee flexion. For cycle 100 tibial displacement, there was no difference between intact (4.41 mm) and SimPCL/IBSTA (5.59 mm, P = .391). There was a difference between intact (4.41 mm) and SimPCL (7.19 mm, P = .006) , but there was no significant difference between SimPCL/IBSTA (5.59 mm) and SimPCL (7.19 mm, P = .140). There was a difference in cycle 1 stiffness between intact (62.3 N/mm) and Sim2PCL (37 N/mm, P = .005). There was no difference between other groups. CONCLUSIONS: In this cadaver study, there was a 1.18-mm average difference in posterior tibial displacement when comparing intact and SimPCL/IBSTA. The internal brace construct should be tensioned and fixed at approximately 100° of knee flexion to prevent loss of full flexion. CLINICAL RELEVANCE: The presented biomechanical data for internal bracing of PCL injuries may lead to improved surgical techniques.
format Online
Article
Text
id pubmed-8689244
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86892442021-12-30 Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion Ostrander, Roger Jordan, Steve Konicek, John Baldwin, William Arthrosc Sports Med Rehabil Original Article PURPOSE: To evaluate the biomechanics of simulated posterior cruciate ligament injuries (SimPCL) with and without internal brace suture tape augmentation (IBSTA) in cadaver knees. METHODS: A total of 20 cadaveric knees were used, all male, with an average age of 65 ± 18 years. Femoral tunnel isometry was evaluated at the 1/11 o’clock and 2/10 o’clock femoral positions. SimPCL were created in 6 knees. IBSTA was performed, and load data were collected through knee range of motion. An additional 6 specimens were evaluated at the 1/11 femoral tunnel position, and load cell recordings were obtained at 10 different knee flexion angles. Cyclic displacement in 8 cadaver knees was assessed using an Instron machine. Load and displacement data were recorded. Testing was performed under 3 conditions for each specimen: intact PCL, SimPCL, and SimPCL/IBSTA using the 1/11 femoral tunnel position. RESULTS: There was no difference in isometry when comparing the 1/11 o’clock (7.1 ± 4.0 ft∗lb) femoral position and the 2/10 o’clock (7.6 ± 4.2 ft∗lb) position (P = .467). SimPCL/IBSTA suture tape tension gradually increased with progressive flexion to a peak at approximately 120° of knee flexion. For cycle 100 tibial displacement, there was no difference between intact (4.41 mm) and SimPCL/IBSTA (5.59 mm, P = .391). There was a difference between intact (4.41 mm) and SimPCL (7.19 mm, P = .006) , but there was no significant difference between SimPCL/IBSTA (5.59 mm) and SimPCL (7.19 mm, P = .140). There was a difference in cycle 1 stiffness between intact (62.3 N/mm) and Sim2PCL (37 N/mm, P = .005). There was no difference between other groups. CONCLUSIONS: In this cadaver study, there was a 1.18-mm average difference in posterior tibial displacement when comparing intact and SimPCL/IBSTA. The internal brace construct should be tensioned and fixed at approximately 100° of knee flexion to prevent loss of full flexion. CLINICAL RELEVANCE: The presented biomechanical data for internal bracing of PCL injuries may lead to improved surgical techniques. Elsevier 2021-10-29 /pmc/articles/PMC8689244/ /pubmed/34977635 http://dx.doi.org/10.1016/j.asmr.2021.08.008 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Ostrander, Roger
Jordan, Steve
Konicek, John
Baldwin, William
Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
title Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
title_full Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
title_fullStr Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
title_full_unstemmed Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
title_short Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
title_sort suture tape–augmented posterior cruciate ligament repair should be tensioned and fixed at approximately 100° knee flexion to prevent loss of full flexion
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8689244/
https://www.ncbi.nlm.nih.gov/pubmed/34977635
http://dx.doi.org/10.1016/j.asmr.2021.08.008
work_keys_str_mv AT ostranderroger suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion
AT jordansteve suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion
AT konicekjohn suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion
AT baldwinwilliam suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion