Cargando…
Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion
PURPOSE: To evaluate the biomechanics of simulated posterior cruciate ligament injuries (SimPCL) with and without internal brace suture tape augmentation (IBSTA) in cadaver knees. METHODS: A total of 20 cadaveric knees were used, all male, with an average age of 65 ± 18 years. Femoral tunnel isometr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8689244/ https://www.ncbi.nlm.nih.gov/pubmed/34977635 http://dx.doi.org/10.1016/j.asmr.2021.08.008 |
_version_ | 1784618512577200128 |
---|---|
author | Ostrander, Roger Jordan, Steve Konicek, John Baldwin, William |
author_facet | Ostrander, Roger Jordan, Steve Konicek, John Baldwin, William |
author_sort | Ostrander, Roger |
collection | PubMed |
description | PURPOSE: To evaluate the biomechanics of simulated posterior cruciate ligament injuries (SimPCL) with and without internal brace suture tape augmentation (IBSTA) in cadaver knees. METHODS: A total of 20 cadaveric knees were used, all male, with an average age of 65 ± 18 years. Femoral tunnel isometry was evaluated at the 1/11 o’clock and 2/10 o’clock femoral positions. SimPCL were created in 6 knees. IBSTA was performed, and load data were collected through knee range of motion. An additional 6 specimens were evaluated at the 1/11 femoral tunnel position, and load cell recordings were obtained at 10 different knee flexion angles. Cyclic displacement in 8 cadaver knees was assessed using an Instron machine. Load and displacement data were recorded. Testing was performed under 3 conditions for each specimen: intact PCL, SimPCL, and SimPCL/IBSTA using the 1/11 femoral tunnel position. RESULTS: There was no difference in isometry when comparing the 1/11 o’clock (7.1 ± 4.0 ft∗lb) femoral position and the 2/10 o’clock (7.6 ± 4.2 ft∗lb) position (P = .467). SimPCL/IBSTA suture tape tension gradually increased with progressive flexion to a peak at approximately 120° of knee flexion. For cycle 100 tibial displacement, there was no difference between intact (4.41 mm) and SimPCL/IBSTA (5.59 mm, P = .391). There was a difference between intact (4.41 mm) and SimPCL (7.19 mm, P = .006) , but there was no significant difference between SimPCL/IBSTA (5.59 mm) and SimPCL (7.19 mm, P = .140). There was a difference in cycle 1 stiffness between intact (62.3 N/mm) and Sim2PCL (37 N/mm, P = .005). There was no difference between other groups. CONCLUSIONS: In this cadaver study, there was a 1.18-mm average difference in posterior tibial displacement when comparing intact and SimPCL/IBSTA. The internal brace construct should be tensioned and fixed at approximately 100° of knee flexion to prevent loss of full flexion. CLINICAL RELEVANCE: The presented biomechanical data for internal bracing of PCL injuries may lead to improved surgical techniques. |
format | Online Article Text |
id | pubmed-8689244 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-86892442021-12-30 Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion Ostrander, Roger Jordan, Steve Konicek, John Baldwin, William Arthrosc Sports Med Rehabil Original Article PURPOSE: To evaluate the biomechanics of simulated posterior cruciate ligament injuries (SimPCL) with and without internal brace suture tape augmentation (IBSTA) in cadaver knees. METHODS: A total of 20 cadaveric knees were used, all male, with an average age of 65 ± 18 years. Femoral tunnel isometry was evaluated at the 1/11 o’clock and 2/10 o’clock femoral positions. SimPCL were created in 6 knees. IBSTA was performed, and load data were collected through knee range of motion. An additional 6 specimens were evaluated at the 1/11 femoral tunnel position, and load cell recordings were obtained at 10 different knee flexion angles. Cyclic displacement in 8 cadaver knees was assessed using an Instron machine. Load and displacement data were recorded. Testing was performed under 3 conditions for each specimen: intact PCL, SimPCL, and SimPCL/IBSTA using the 1/11 femoral tunnel position. RESULTS: There was no difference in isometry when comparing the 1/11 o’clock (7.1 ± 4.0 ft∗lb) femoral position and the 2/10 o’clock (7.6 ± 4.2 ft∗lb) position (P = .467). SimPCL/IBSTA suture tape tension gradually increased with progressive flexion to a peak at approximately 120° of knee flexion. For cycle 100 tibial displacement, there was no difference between intact (4.41 mm) and SimPCL/IBSTA (5.59 mm, P = .391). There was a difference between intact (4.41 mm) and SimPCL (7.19 mm, P = .006) , but there was no significant difference between SimPCL/IBSTA (5.59 mm) and SimPCL (7.19 mm, P = .140). There was a difference in cycle 1 stiffness between intact (62.3 N/mm) and Sim2PCL (37 N/mm, P = .005). There was no difference between other groups. CONCLUSIONS: In this cadaver study, there was a 1.18-mm average difference in posterior tibial displacement when comparing intact and SimPCL/IBSTA. The internal brace construct should be tensioned and fixed at approximately 100° of knee flexion to prevent loss of full flexion. CLINICAL RELEVANCE: The presented biomechanical data for internal bracing of PCL injuries may lead to improved surgical techniques. Elsevier 2021-10-29 /pmc/articles/PMC8689244/ /pubmed/34977635 http://dx.doi.org/10.1016/j.asmr.2021.08.008 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Ostrander, Roger Jordan, Steve Konicek, John Baldwin, William Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion |
title | Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion |
title_full | Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion |
title_fullStr | Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion |
title_full_unstemmed | Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion |
title_short | Suture Tape–Augmented Posterior Cruciate Ligament Repair Should Be Tensioned and Fixed at Approximately 100° Knee Flexion to Prevent Loss of Full Flexion |
title_sort | suture tape–augmented posterior cruciate ligament repair should be tensioned and fixed at approximately 100° knee flexion to prevent loss of full flexion |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8689244/ https://www.ncbi.nlm.nih.gov/pubmed/34977635 http://dx.doi.org/10.1016/j.asmr.2021.08.008 |
work_keys_str_mv | AT ostranderroger suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion AT jordansteve suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion AT konicekjohn suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion AT baldwinwilliam suturetapeaugmentedposteriorcruciateligamentrepairshouldbetensionedandfixedatapproximately100kneeflexiontopreventlossoffullflexion |