Cargando…

Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research

Small animal x-ray irradiation platforms are expanding the capabilities and future pathways for radiobiology research. Meanwhile, proton radiotherapy is transitioning to a standard treatment modality in the clinician’s precision radiotherapy toolbox, highlighting a gap between state-of-the-art clini...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Michele M, Irmen, Peyton, Shoniyozov, Khayrullo, Verginadis, Ioannis I, Cengel, Keith A, Koumenis, Costantinos, Metz, James M, Dong, Lei, Diffenderfer, Eric S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8690893/
https://www.ncbi.nlm.nih.gov/pubmed/31075786
http://dx.doi.org/10.1088/1361-6560/ab20d9
_version_ 1784618698201366528
author Kim, Michele M
Irmen, Peyton
Shoniyozov, Khayrullo
Verginadis, Ioannis I
Cengel, Keith A
Koumenis, Costantinos
Metz, James M
Dong, Lei
Diffenderfer, Eric S
author_facet Kim, Michele M
Irmen, Peyton
Shoniyozov, Khayrullo
Verginadis, Ioannis I
Cengel, Keith A
Koumenis, Costantinos
Metz, James M
Dong, Lei
Diffenderfer, Eric S
author_sort Kim, Michele M
collection PubMed
description Small animal x-ray irradiation platforms are expanding the capabilities and future pathways for radiobiology research. Meanwhile, proton radiotherapy is transitioning to a standard treatment modality in the clinician’s precision radiotherapy toolbox, highlighting a gap between state-of-the-art clinical radiotherapy and small animal radiobiology research. Comparative research of the biological differences between proton and x-ray beams could benefit from an integrated small animal irradiation system for in vivo experiments and corresponding quality assurance (QA) protocols to ensure rigor and reproducibility. The objective of this study is to incorporate a proton beam into a small animal radiotherapy platform while implementing QA modelled after clinical protocols. A 225 kV x-ray small animal radiation research platform (SARRP) was installed on rails to align with a modified proton experimental beamline from a 230 MeV cyclotron-based clinical system. Collimated spread out Bragg peaks (SOBP) were produced with beam parameters compatible with small animal irradiation. Proton beam characteristics were measured and alignment reproducibility with the x-ray system isocenter was evaluated. A QA protocol was designed to ensure consistent proton beam quality and alignment. As a preliminary study, cellular damage via γ-H2AX immunofluorescence staining in an irradiated mouse tumor model was used to verify the beam range in vivo. The beam line was commissioned to deliver Bragg peaks with range 4–30 mm in water at 2 Gy min(−1). SOBPs were delivered with width up to 25 mm. Proton beam alignment with the x-ray system agreed within 0.5 mm. A QA phantom was created to ensure reproducible alignment of the platform and verify beam delivery. γ-H2AX staining verified expected proton range in vivo. An image-guided small animal proton/x-ray research system was developed to enable in vivo investigations of radiobiological effects of proton beams, comparative studies between proton and x-ray beams, and investigations into novel proton treatment methods.
format Online
Article
Text
id pubmed-8690893
institution National Center for Biotechnology Information
language English
publishDate 2019
record_format MEDLINE/PubMed
spelling pubmed-86908932021-12-21 Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research Kim, Michele M Irmen, Peyton Shoniyozov, Khayrullo Verginadis, Ioannis I Cengel, Keith A Koumenis, Costantinos Metz, James M Dong, Lei Diffenderfer, Eric S Phys Med Biol Article Small animal x-ray irradiation platforms are expanding the capabilities and future pathways for radiobiology research. Meanwhile, proton radiotherapy is transitioning to a standard treatment modality in the clinician’s precision radiotherapy toolbox, highlighting a gap between state-of-the-art clinical radiotherapy and small animal radiobiology research. Comparative research of the biological differences between proton and x-ray beams could benefit from an integrated small animal irradiation system for in vivo experiments and corresponding quality assurance (QA) protocols to ensure rigor and reproducibility. The objective of this study is to incorporate a proton beam into a small animal radiotherapy platform while implementing QA modelled after clinical protocols. A 225 kV x-ray small animal radiation research platform (SARRP) was installed on rails to align with a modified proton experimental beamline from a 230 MeV cyclotron-based clinical system. Collimated spread out Bragg peaks (SOBP) were produced with beam parameters compatible with small animal irradiation. Proton beam characteristics were measured and alignment reproducibility with the x-ray system isocenter was evaluated. A QA protocol was designed to ensure consistent proton beam quality and alignment. As a preliminary study, cellular damage via γ-H2AX immunofluorescence staining in an irradiated mouse tumor model was used to verify the beam range in vivo. The beam line was commissioned to deliver Bragg peaks with range 4–30 mm in water at 2 Gy min(−1). SOBPs were delivered with width up to 25 mm. Proton beam alignment with the x-ray system agreed within 0.5 mm. A QA phantom was created to ensure reproducible alignment of the platform and verify beam delivery. γ-H2AX staining verified expected proton range in vivo. An image-guided small animal proton/x-ray research system was developed to enable in vivo investigations of radiobiological effects of proton beams, comparative studies between proton and x-ray beams, and investigations into novel proton treatment methods. 2019-07-04 /pmc/articles/PMC8690893/ /pubmed/31075786 http://dx.doi.org/10.1088/1361-6560/ab20d9 Text en https://creativecommons.org/licenses/by-nc/3.0/Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence.
spellingShingle Article
Kim, Michele M
Irmen, Peyton
Shoniyozov, Khayrullo
Verginadis, Ioannis I
Cengel, Keith A
Koumenis, Costantinos
Metz, James M
Dong, Lei
Diffenderfer, Eric S
Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
title Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
title_full Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
title_fullStr Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
title_full_unstemmed Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
title_short Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
title_sort design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8690893/
https://www.ncbi.nlm.nih.gov/pubmed/31075786
http://dx.doi.org/10.1088/1361-6560/ab20d9
work_keys_str_mv AT kimmichelem designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT irmenpeyton designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT shoniyozovkhayrullo designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT verginadisioannisi designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT cengelkeitha designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT koumeniscostantinos designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT metzjamesm designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT donglei designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch
AT diffenderfererics designandcommissioningofanimageguidedsmallanimalradiationplatformandqualityassuranceprotocolforintegratedprotonandxrayradiobiologyresearch